| 1 | M&L for LT UG Cable fault finding/testing from Panel to fault location including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/Transformer etc and re-terminating the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of fault finding/testing work complete all as specified and directed for any size of cable.Note:- Job will be measured after fault detection of any type regarding this decision of Engineer-in-charge shall be final & binding. |
| 2 | M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 240 to 400 Sqmm 3.5 core including all accessories required. [Make :- Denson/M Seal/3M] |
| 3 | M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 150 to 185 Sqmm 3.5 core including all accessories required. [Make :- Denson/M Seal/3M] |
| 4 | M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 70 to 120 Sqmm 3.5 core including all accessories required. [Make :- Denson/M Seal/3M] |
| 5 | M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 16 to 50 Sqmm 3.5 core including all accessories required. [Make :- Denson/M Seal/3M] |
| 6 | Supply, laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes including taking down the existing cable complete of sizes:- 400 Sqmm 3.5 core. |
| 7 | Ditto all as per item No 6 above but 300 sq mm 3.5 core |
| 8 | Ditto all as per item No 6 above but 240 sq mm 3.5 core |
| 9 | Ditto all as per item No 6 above but 185 sq mm 3.5 core |
| 10 | Ditto all as per item No 6 above but 150 sq mm 3.5 core |
| 11 | Ditto all as per item No 6 above but 120 sq mm 3.5 core |
| 12 | Ditto all as per item No 6 above but 95 sq mm 3.5 core |
| 13 | Ditto all as per item No 6 above but 70 sq mm 3.5 core |
| 14 | Ditto all as per item No 6 above but 50 sq mm 3.5 core |
| 15 | Ditto all as per item No 6 above but 35 sq mm 3.5 core |
| 16 | Ditto all as per item No 6 above but 25 sq mm 3.5 core |
| 17 | Ditto all as per item No 6 above but 16 sq mm 4 core |
| 18 | Ditto all as per item No 6 above but 10 sq mm 2 core |
| 19 | Ditto all as per item No 6 above but 10 sq mm 4 core |
| 20 | Ditto all as per item No 6 above but 6 sq mm 2 core |
| 21 | Ditto all as per item No 6 above but 6 sq mm 4 core |
| 22 | Excavation in trenches in hard/dense soil n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed by Engr-in-charge |
| 23 | Excavation in trenches in soft/dis integrated rock n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed by Engr-in-charge. |
| 24 | Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr-in-charge. |
| 25 | Removing excavated surplus soil / Soft disintegrated rock to a distance n exc 50 m and depositing where directed at a level n exc 1.5 mtr above starting point all as specified and directed by Engr-in-charge. |
| 26 | Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 27 | Supply and laying 90 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 28 | Supply and laying 80mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc. complete all as specified and directed. |
| 29 | Ditto all as per item No 28 above but 50 mm bore complete all as directed |
| 30 | Material and labour for cutting of existing road/ hard standing by providing suitable T&P to make suitable size bore for fixing 80/50/40 mm dia pipe in road crossing etc. including the cost of making good the disturbed surface and matching with existing (Chequered tiles/Road/PCC) complete all as specified and directed by Engr-In-Charge |
| 31 | Supply, fix, test and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, insulation class F suitable for indoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM specifiactions including taking down the existing one complete all as specified and as directed by Engr-in-Charge. |
| 32 | Supply, fix, test and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP66, IEC 61439-6, copper contact, class F insulation suitable for outdoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM specifiactions including taking down the existing one complete all as specified and as directed by Engr-in-Charge. |
| 33 | Supply, fix, test and commissioning of aluminium enclosure of 2500 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, class F insulation suitable for indoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM specifiactions including taking down the existing one complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 34 | Supply, fix, test and commissioning of aluminium enclosure of 2500 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, class F insulation suitable for indoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM specifiactions including taking down the existing one complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |