| 1 | Providing and fixing SFRC Road Gully grating and Frame of standard Size. Complete in all respects as per satisfaction of the Engineer in Charge ( Analysis annexed),, |
| 2 | Providing and fixing aluminum ladder stair 1.5 mtr long including fitting, jointing, fasner complete in all respect as per design satisfaction Engineer-in-charge |
| 3 | NS Item -_ NS Item - HT Panel -Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG)a). VCB, 11KV, 630Amp, 50KA.b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s.c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2.d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays.e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above.f). Master trip relay -2 no’s.g). Indicator type Annunciator panel with buzzer.h). Digital Volt Meter- 0-11 KV.i). Digital Amp Meter- 0-100 Amp.j). RYB/ Trip/Closing/Spring charged indicator lamp.k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay.l) TNC Switch for Operation. m)Multifunction Meter EM6400NG.n)TCS Relay for Safety. |
| 4 | NS Item -Providing and fixing 200 AMP copper bus bar junction bar complete in all respect |
| 5 | NS Item -Providing and fixing Ductile iron double flanged swing check type reflux (non return) valves PN- 1.6 including nuts and bolts, rubber sheet, carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect (Make IVC and VAG) = 200 mm i/d ( Pumps) |
| 6 | NS Item -Providing and fixing of 50 watt led lights make havells complete in all respect as per derication of Engineer- in-charge. |
| 7 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 : 400 mm dia Ductile Iron Double Flanged |
| 8 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 : 600 mm dia Ductile Iron Double Flanged |
| 9 | NS Item -Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 20.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect the indicated. LPM - 10500and BHP - 80 ( Aqua and Kishor).... |
| 10 | AUTOMATIC POWER FACTOR CONTROL PANEL (APFC) Supply erection testing and commissioning of Automatic Power Factor control panel as per required capacitor complete with digital screen and including Distribution Panel, ACB as required as per site Condition, Coupler, DG Change over specification mentioned in the as per approved DNIT. |
| 11 | Supplying erection, testing of fully automatic electric control panel board consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect (80 HP) |
| 12 | Operation and maintenance of proposed Storm water Disposals complete in all respect including all civil, electrical and mechanical installation and rising mains upto final disposal point, complete scope of work under this contract as per operation and maintenance Manual of NIT(Attached in additional documents) for a period of 5 years after 12 months defect liability period and 3 months trial run period.(Charged to A/mtc estimate year wise) complete in all respect. i) Operation and Maintenance during defect liability period (Operation Only) |
| 13 | Operation and maintenance during 1st year after defect liability period. |
| 14 | Operation and maintenance during 2nd year |
| 15 | Operation and maintenance during 3rd year |
| 16 | Operation and maintenance during 4th year |
| 17 | Operation and maintenance during 5th year |
| 18 | HSR Items Please Enable Macros to View BoQ information |