| 1 | Supply, Installation, Testing and Commisoning of BED SIDE UNIT - WirelessFeatures : 1. Nurse call , 2. Code blue, 3. Maid call, 4. Extra support & RFID AlsoBedside Unit suitable for installation in the bed head Panel unit or for wall mounting. Adheres to the size standards of 6 modular. Dimensions: height 9.5 cm and width 22.5 cm. Device should be Germ-inhibiting membrane keypad with the following buttons: Nurse Call (left side top), Code Blue (left side bottom), Maid Call , Extra Support. Bedside unit should contain in-built unique staff identification with an RFID terminal. Every calling button should have its own reassuring light. Every device should work through wired, wireless & Hybrid. If wired, it should work through the LAN cable; if wireless, it should work through WiFi. Every device should be capable enough to work both wired and wireless simultaneously. If a wire gets disconnected, device should switch to WiFi automatically. Devices work through an AC or UPS power supply of 230 V and 0.2 Ames from the bed side unit. |
| 2 | Supply, Installation, Testing and Commisoning of Hand Held Device Hand held device - Nurse Call with a cable length of 3 meters & Versatile for bed rails only with Nurse Call Button. The hand-held device shall be connected to the bedside unit via a wire. Hand-held device cable thickness: 4.85mm. Device should be able to communicate on Ethernet switch. |
| 3 | Supply, Installation, Testing and Commisoning of PULL Cord Pull Cord - Restroom Unit : Nurse Call with waterproof design with antibacterial cord. Actuating the pull cord has the same effect as pressing a call button and equip with a reassurance light (Red) which gives the patient an immediate visual indication that help is on the way. In device design, it is necessary to mention \\"SOS\\" on the button. Should come with a 3 to 5 meter rope for activating the call. The pull cord shall be connected to the main call point, which activates the nurse's call when pulled. Call point shall have a unique software ID for identification in the server or nurse calling software. Dimension: Height 8.5 cm and width 8.5 cm & Rope length 45 cm to 180 cm. Nurse call with waterproof design with antibacterial cord |
| 4 | Supply, Installation, Testing and Commisoning of RFID Enabled Nurse Identity Card to cancel the call. |
| 5 | Supply, Installation, Testing and Commisoning of Door Light Door Light : 360° bright, eye-catching colors from long distances when calls are active. Three LED indication fields in the colors Green (Nurse Call), Blue (Code blue), and Red (Maid Call & Extra support). Door Light: Should come in a round shape, providing better visibility and aesthetic appeal. The call light should exhibit the alarm indications in different scenarios based on the priority of different alarms. Dimension: diameter 9 cm, top side with ABS transparent plastic & bottom holder should be made of aluminium. |
| 6 | Supply, Installation, Testing and Commisoning of Central Management System Fully pre-installed and ready to operate software interfaces seamlessly with external hardware and nurse station software, enhancing the reliability of central services and connections. The nurse station software includes several key features: Auto Fault Detection: •The system checks component status every 60 seconds, and notifies maintenance staff of anyproblems or disconnections. Support: A Local server placed at the hospital server room to process the nurse call application. •Auto Fault Detection: Should continuously checks the status of each device every second and notices maintenance staff if any problem or dis-connectivity is detected. •Built-in backup communication protocol: Provides access to a built-in backup communication protocol in order to connect to hospital Wi-Fi during service downtime for the wired system.•Strategic report generation. •Mobile application. • Up gradable to Smart OPD calling system. •Upgadable to Smart Queue management systemIntegration: Should be able to support the integration of the Hospital Information System (HIS) for all the nurse stations. Smart Dashboard: Can be able to monitor entire system functionality via a web applicationStrategic report generation: Should Generates detailed reports on call response times, frequency of calls, TAT, and peak usage periods to enhance operational efficiency. |
| 7 | Supply, Installation, Testing and Commisoning of Android Television (ATV1)Specifications: 32\\"\\" inches HD Ready LED Smart Android TV . Brightness: 250 nits, 75 Hz Refresh Rate. Aspect Ratio 16:09 3.Technology & Resolution: HD Ready, 1366 x 768. Wi-Fi Type: Dual Band WiFi: 2.4 GHz and 5 GHz, Ports: 2 x HDMI & 2 x USBPower Requirement: AC 100 - 240 V, 50/60 Hz |
| 8 | Supply, Installation, Testing and Commisoning of Wireless Bed Button 1. General Description- The device is designed for triggering a nurse call with a simple button press.- Functions as a wireless call device integrated with the Nurse Call System.- The watch connects to the Bedside Unit via Bluetooth for call transmission. 2. Key Features- Uses an nRF series chipset for efficient signal processing and communication.- Provides a reliable Bluetooth connection to the bedside unit, which relays the call.- IP66 protection, making it resistant to dust and water. 3. Technical Specifications- Operating Temperature Range: -20°C to 50°C- Battery Life: Up to 20 days (assuming fewer than 10 calls per day)- Color: Black- Communication Protocol: BLE 4. Applications- Nurse Call System: Used to alert nurses instantly when the button is pressed.- Hospital Emergency Response: Enables quick assistance for patients in need.- Healthcare Staff Communication: Enhances efficiency in hospitals by reducing response time. 5. User Interaction & Functionality- The device is worn as a watch for easy access.- A button press triggers the nurse call, which is relayed through the Bedside Unit to be displayed at the Nurse Station.- The call status updates in real-time on the Nurse Station display.- Can be integrated with mobile applications or cloud platforms for data analysis and reporting. 6. Durability & Maintenance- Designed with robust casing to withstand hospital environments.- Requires minimal maintenance with a replaceable battery system.- Ensures long-term reliability with power-efficient chipset design. 7. Regulatory Compliance- Meets IP66 standards for protection against dust and water.- Designed with compliance to BLE transmission standards. |
| 9 | Supply, Installation, Testing and Commisoning of Nurse Station Display Software : It should show every active call along with call types on a 32-inch display. Should be able to view every patient's information in detail through HIS integration. There shouldn't be no limit for the nurse station display count. It should be able to be used anywhere. Must be capable enough to configure more than 50 devices with a single nurse station display. Should display & notify according to the call priority with the room number (voice). Nurse Station Alert: Must specify the room number in the voice note. |
| 10 | Supply, Installation, Testing and Commisoning of Ethernet Switch 12M : A 12-port Ethernet switch is a networking device that connects up to 12 dififierent devices on a Local Area Network (LAN). It enables multiple devices, such as computers, printers, and servers, to communicate efifiiciently and transfier data at high speeds. This type ofi switch is a common and cost-efifiective solution fior small- to medium-sized businesses and home networks with many connected devices |
| 11 | Supply, Installation, Testing and Commisoning of Ethernet Switch 24M : A 24-port Ethernet switch is a networking device that connects up to 24 dififierent devices on a Local Area Network (LAN). It enables multiple devices, such as computers, printers, and servers, to communicate efifiiciently and transfier data at high speeds. This type ofi switch is a common and cost-efifiective solution fior small- to medium-sized businesses and home networks with many connected devices |
| 12 | Supply, Installation, Testing and Commisoning of Ethernet Switch 48M : A 48-port Ethernet switch is a networking device that connects up to 48 dififierent devices on a Local Area Network (LAN). It enables multiple devices, such as computers, printers, and servers, to communicate efifiiciently and transfier data at high speeds. This type ofi switch is a common and cost-efifiective solution fior small- to medium-sized businesses and home networks with many connected devices |
| 13 | Supply, Installation, Testing and Commisoning of Rack : A 2U rack refers to equipment that occupies 2 Rack Units (U) of vertical space in a standard 19-inch rack, which is equivalent to 3.5 inches (88.9 mm) high. Rack units are a standardized measurement for server and network equipment, with each 1U being 1.75 inches tall, and 2U devices being twice that height. This standardized size allows for the efficient organization and integration of various equipment like servers, network switches, and audio/video gear in data centers and server rooms. |
| 14 | Supply, Installation, Testing and Commisoning of Router : R15 | WiFi 6 Speed 1500 Mbps |Covers Upto 2500 Sq. Ft.| Dual Band | Gigabit Port| AI Powered Mesh Router |High-Performance |High-Gain Antennas |MTCTE Certified |
| 15 | Supply, Installation, Testing and Commisoning of Nurse Call Communication Cabling : Laying of 25mm Conduit and Nurse Call Communication Cable with Wall Chiseling from each Nurse Call Point to the respective Nurse Station. Please Enable Macros to View BoQ information |