| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 2 | Demolition of cement cocrete any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | M&L for 75mm thick PCC (1:3:6) type C-2, using 40mm graded stone aggregate as in plinth protection/path laid in panels, finish the top surfaces even and smooth complete including filling the joints with mastic compound complete all as specified and directed. |
| 4 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed. |
| 5 | M&L for brick work with using flyash bricks modular size straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed. |
| 6 | M&L for Vitrified ceramic coloured tiles 8mm to 9 mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc, over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matching, complete all as specified and directed. |
| 7 | M&L for Vitrified ceramic coloured tiles 8mm to 9mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm as in riser of steps, skirting, dado and pillar etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over and including 10mm thick rendering in CM (1:4) complete all as specified and directed. |
| 8 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of CM (1:6) complete all as specified and directed. |
| 9 | M&L for glazed ceramic colour joint free tiles tiles in verticle surface area exc 0.06 sqm but n exc 0.16 sqm thick set and jointed in neat cement slurry over and including 10 mm thick 1:4 cement mortar plaster and pointed in coloured cement to match complete all as specified and directed. |
| 10 | M&L for 25 mm thick cement concrete (1:2:4) type B-0, using 12.5 mm graded stone aggregate as in sub base of flooring etc complete all as specified and directed. |
| 11 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc led in any mortar all as specified and directed. |
| 12 | M&L for granite (of any type) stone slab 18 to 20mm thick machine cut and machine polised, in skirting, Kitcehn platform /dado etc laid over cement screed jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding the edges half round and polishing including pinning in brick/concrete wall to hold & support the vertical surfaces to granite work including drilling to wall over and including 15mm thick screed bed of cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L for Baroda green marble 14 -16 mm thick (table rubbed and polished ) in step, jambs, pillers , window cills, cooking plateforms and the like in CM (1:4) incl pointing in white cement (1:2), using marble dust with admixture of pigment to match with marble including half round moulding and making hole for gas pipe over and including 15mm thick screed bed of cement mortar 1:6 complete all as specified and directed. |
| 14 | M&L for Machine cut Kota stone slab flooring 18-20 mm thick, laid over & including screed bed of 15 mm thick in cement mortar (1:6) and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing complete all as specified and directed. |
| 15 | M&L for Kota stone slab 16-18 cm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 16 | M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate, as in foundation filing, mass concrete, sub base of floor, etc complete all as specified and directed. |
| 17 | S&F in repairs 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading ) in square n.exc 0.5 Sqm in each panes including Hacking out old broken glass complete all as specified and directed. |
| 18 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 19 | M&L for 15mm thick plaster in CM (1:6) on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for 15mm thick plaster in CM (1:4) on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for rendering 5mm thick in ceiling CM (1:3) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed. |
| 23 | M&L for preparing plastered surface of wal and applying 1mm thick wall care Putty on wall complete as specified and directed.Make: Birla/Asian/JK / make as per Particular Specification (list of Make) as approved by GE. |
| 24 | M&L for rendering 5 mm thick in CM (1:3) on RCC Chajja / Facia over 20mm thick in CM 1:4 as dubbing coat etc complete all as specified and directed. |
| 25 | M&L for three coats of white wash on ceiling on new plastered surfaces including preparation of surfaces complete all as specified and directed. |
| 26 | M&L for two coats of white wash on ceiling on old plastered surfaces including preparation of surfaces complete all as specified and directed. |
| 27 | M&L for preparing newely plastered surface of wall and applying two coat of cement base paint etc complete all as specified and directed. |
| 28 | M&L for preparation of old plastered surfaces oof wall and applying two coat of oil emulsion distemper complete all as specified and directed. |
| 29 | M&L for preparation of old plastered surface of wall and applying two coat of cement base paint etc complete all as specified and directed. |
| 30 | M&L for preparation of old surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic oil bound distemper make the surface smooth using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge. |
| 31 | M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic weather proof emulsion paint (walmasta of Berger paint / Asian paint / Nerolac / make as per Particular Specification (list of Make) as approved by GE) complete all as specified and directed at site by Engineer-in-Charge.Note: (i) All stages of surface preparation and finishing coats shall be carried out only after stage passed by the Engr-in-Charge/GE.(ii) A written warranty for four years or as per the manufacturer’s instructions, whichever is greater, shall be submitted by the contractor |
| 32 | M&L for preparation of new surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic weather proof emulsion paint (walmasta of Berger paint or equivalent in Asian paint, Nerolac etc ) complete all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.Note: (i) All stages of surface preparation and finishing coats shall be carried out only after stage passed by the Engr-in-Charge/GE.(ii) A written warranty for four years or as per the manufacturer’s instructions, whichever is greater, shall be submitted by the contractor |
| 33 | M&L for primer on old /new surface of wall with alkali resistant priming paint complete as specified and directed. |
| 34 | M&L for preparation of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 35 | M&L for preparation of new wooden surface of any description not other wise described over 10 cm widht or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed. |
| 36 | M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed. |
| 37 | M&L for preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 38 | M&L for two coats of painting with Damp guard (or make as per Particular Specification (list of Make) as approved by GE)) water proofing liquid including preparation of new plastered surfaces complete all as specified and directed by Engineer-in-Charge. |
| 39 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed. |
| 40 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed. |
| 41 | Taking down shutter of any description exc 1 Sqm but n.exc 2 sqm each complete all as specified and directed. |
| 42 | Taking down shutter of any description n.exc 1 Sqm each complete all as specified and directed. |
| 43 | S&F powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) shall be two part as upper patr shall be three movable shutter and lower part consist three shutter (one openable in centre and both side fixed type shutter with frosted glass) with following specification and making good the adjacent side of jombs of windows by plastering in CM (1:3) even and smooth complete etc shifting of existing cooler stand where required complete all as specified and as directed by Engr-in-charge(ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick.(Min)(iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick.(Min)(iv) 4 mm thick glass superior quality.(Min)(v) IDPE Rubber guasket for fixing of glass.(vi) Locking cleats per shutter -01 Nos.(Min)(vii) Sliding rollers per shutter - 02 Nos.(Min)(viii) Stainless steel wire cloth 0.30mm nominal dia of wire and average width of aperture 1.40mm for shutters 01 Nos.(Ix) fixing screw for frame with wall per windows- 08 Nos. |
| 44 | S&F in repairs fabricating coloured powder coated aluminium frame work,door shutter ,windows , ventilators, partisions with one or more rebates sections of approved tint as required for partions including beading, cleat, screws,fasteners, plugs, for fixing with wall/ceiling columns/beams etc complete all as specified and directed. |
| 45 | S&F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jombs all around in CM (1:3) finishing even and smooth complete all as specified and directed. |
| 46 | S&F in repairs aluminium coloured power coated door shutters, aluminium section weighing min 0.55 Kg/m including necesssary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door, pad lock, hinges, anodised aluminium snap beading screws etc complete all as specified and directed. |
| 47 | M&L for complete sunken floor treatment by providing water proofing treatment to sunken floor surfaces of RCC slab by the following specifications complete all as specified and directed :- (a) PCC (1:1.5:3) type A-0, using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compound manufactured by Dr FIXIT or Make/Brand as specified in Particular Specification. and finished the surface even & smooth without using extra cement. (b) Rendering 15mm thick in CM (1:3) mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion. (c) Applying surfaces with bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm on sunken surfaces of floor & wall and provide necessary connections to soil/waste pipe from WC/Nahanni trap etc including demolition ,cutting holes and making good the disturbed surface as per existing complete all as specified and directed. (d) Applying two coats of tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane. (e) Laying 3 mm thick APP modified water proofing membrane with 100 mm over laps sealed and bounded to the surfaces by 'torchon' method.Note: Top Floor Area shall be measured for payment. |
| 48 | Cleaning of roof slab /chajja with sweeping with brooms removing all depositions /mud/vegetations washing with water etc and removing the spoil to a distance exc 50 mtr complete all as specified and directed. Please Enable Macros to View BoQ information |
| 49 | Cleaning of roof slab /chajja with sweeping with brooms removing all depositions /mud/vegetations washing with water etc and removing the spoil to a distance exc 50 mtr complete all as specified and directed. Please Enable Macros to View BoQ information |