| 1 | ELECTRICAL |
| 2 | OD509437/2025-2026:Supply of 3 phase 3 HP/2.23 KW. bore well submersible pump set capable to discharge 14 to 40 LPM of clear water to a head 126-252 M. suitable to work with 415V,50HZ,A.C supply including of all taxes. Makes prefared :- Deccan EKKI - ER 41H 40 stage Or equ / Texmo / Deccan Kirloskarbrands |
| 3 | OD509424/2025-2026:Submersible pump controllers with ammeter,volt meter,SPP, for three phase 3 H.P submersible motor pumps (MU-G6 DOL ) |
| 4 | 90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. |
| 5 | OD509415/2025-2026:Supply and providing 4 pole enclosure for independent mounding of MCB/RCCB/Isolator etc. |
| 6 | OD509422/2025-2026:S&F 40 A,4 pole RCCB 100/300 mA |
| 7 | OD509431/2025-2026:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement, of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, color washing etc. including giving necessary connections, Fuse links as required. Switch disconnector unit 32A TPN AC23 A |
| 8 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 9 | 90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm |
| 10 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 11 | 1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm |
| 12 | OD509434/2025-2026:supply and providing 38/40 mm outer dia CPVC pipe for delivery line |
| 13 | OD509432/2025-2026:Supply and providing adaptor suitable for 38/40 mm inner dia CPVC pipe |
| 14 | OD509416/2025-2026:Supply and providing 40 mm dia G.I pipe (B class) for delivery line |
| 15 | OD509425/2025-2026:Supply and providing 40 mm dia GI bend |
| 16 | OD509420/2025-2026:Supply and Providing 40 mm dia GI coupling |
| 17 | OD509417/2025-2026:Supply and providing 40 mm dia G.M Non Return Valve |
| 18 | OD509423/2025-2026:Supply and providing 40 mm dia GI union |
| 19 | OD509418/2025-2026:Supply and providing good quality garware make nylon marine rope 16 mm size with required PVC tie-bad ad tieing the pump set with required outside the well |
| 20 | OD509421/2025-2026:Supply and providing PVC Bore Well End Cap (160 mm) 6 inch Heavy |
| 21 | OD509433/2025-2026:Supply and providing M.S. borewell clamb with bolt and nut. |
| 22 | OD509429/2025-2026: Charges for installation of above 3 H.P, 3 phase , submersible pumpset into well after connecting the delivery pipes, and lead cables to motor and hanging the unit on poly propelyne rope in trouble free operation and conducting trail run satis factorly . |
| 23 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 24 | OD510394/2025-2026:Providing independent Ordinary pipe earthing using 2.5 meters of 40 mm dia GI pipe,earth wire copper and other specials such as common salt ,charcoal bolts and nuts etc. complete required at site. |
| 25 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 26 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 27 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 28 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 29 | OD509435/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing MS box/earth bus etc. as required including necessary holes as required. 25x3mm brass nut and bolt |
| 30 | OD509436/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing MS box/earth bus etc. as required including necessary holes as required. 25x6mm brass nut and bolt |
| 31 | OD509428/2025-2026: Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc.. |
| 32 | OD509426/2025-2026:Supply and providing 32 A HRC fuse unit with HRC fuse link i the meter box and giving connections as required |
| 33 | OD509430/2025-2026:S&F SMC Meter Box 3750 (350x481x210mm) |
| 34 | OD509427/2025-2026:Preparing completion and test certificates for KSEB connection Please Enable Macros to View BoQ information |