| 1 | Labour only for checking of defective/non fuctional LED street/security light fittings of any type/capacity and making it serviceable by removing carbon at cable joints/ tighting loose cables including repairing of lights (if required) by repair/replacement of unserviceable spare parts after dismantling and taking down lights from its existing position and refixing the same after repair/replacement of unserviceable spare parts including re-assembling and testing complete all as specified and directed.(Note : a- Spare parts/component of street/security light fittings shall be measured and paid seprately under respective items.b: All T&P,safty measures and minor items like PVC tape, thimbles/lugs shall be provided by the contractor without any extra cost) |
| 2 | Supply only LED street light driver suitable for 35 watt to 90 watt LED fittings including connection all as specified and directed. |
| 3 | Supply only LED street light/flood light driver suitable for 120 to 250 watt LED fittings including connection all as specified and directed. |
| 4 | Supply and fix in replacement LED street light fittings 35/45 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed. |
| 5 | Supply and fix in replacement LED street light fittings 60 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed. |
| 6 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable/pipe etc. complete all as specified and as directed |
| 7 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft/loose soil, complete, all as specified and directed. |
| 8 | Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete, all as specified and directed. |
| 9 | Material and labour for providing sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed. |
| 10 | Supplying & laying burnt clay bricks, sub class 'B', laid in trenches over cable protection complete all as specified and directed. |
| 11 | Taking up/down old U/S 6/10/16/25 sqmm 2/4 core XLPE insulated & armoured Al cable all as specified and directed. |
| 12 | Supply, laying and testing of LT cable 1100 volt grade XLPE insulated underground electric cable PVC bedded and sheathed steel wire/strip armoured aluminum stranded conductor of size 10 Sq mm 2 core complete all as specified and directed. |
| 13 | All as per item No - 18 but size 10 Sqmm 4 core |
| 14 | All as per item No - 18 but size 16 Sqmm 4 core |
| 15 | All as per item No - 12 but size 25 Sqmm 4 core |
| 16 | Relaying of existing serviceable underground cable of size 10 Sqmm to 25 Sqmm 2/4 Core obtained from item No 9 complete all as specified and as directed. |
| 17 | Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item |
| 18 | M&L for 40mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 19 | M&L for 25mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 20 | S&F in replacement street light bracket made out of GI tubing 40mm bore medium grade n.exc 1.5 metre long bent to shape as directed including suitable MS clamp of FI 50x6mm with MS bolts nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed. |
| 21 | S & F in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 Nos of single pole MCB SP 6 Amp 'C' series inside the box and all specified and directed. |
| 22 | M&L painting of LT steel tubular pole with one coat of aluminium paint including brackets and synthetic enamel painting of Air Force blue (0.75M above foundation) and 02 Nos alternate layer of red & yellow colour self adhesive reflectic tape of 100MM width & writing pole number on black background with white lettering after scraping /cleaning well the existing rusted surface complete all as specified and directed. |
| 23 | M&L painting of LT octagonal pole bottom portion with two coat of Air Force blue (0.75M above foundation) over a coat of red oxide primer & 02 Nos alternate layer of red & yellow colour self adhesive reflectic tape of 100MM width & writing pole number on black background with white lettering after cleaning well the existing surface complete all as specified and directed. |
| 24 | S & F MCB single pole 240 volts, 'C' curve of rating 6 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed. |
| 25 | S & F MCB TPN 415 volts, 'C' curve of rating 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed. |
| 26 | Supply and fixing of Nature switch smart timer based automatic street light control panel, the panel should be suitable enough to take 3 phase load of 12-15 KW with 3 Nos incoming-outgoing MCBs of 32 Amps & 3 Nos contactors (singlepole/2 pole/3pole) of 32 Amps &circuit wiring with 10 sqmm copper wire. Nature switch smart timer should be maintenance free in design and setting accessible via a mobile app (with bluetooth connectivity). The mobile app should allow user to customize the ON & OFF timings based on Natural light (sensor), Local sunset/Sun rise (Astro) and Time and should also have facility to set input voltage range. The smart timer along with MCB and contractors should be enclosed in a pole/wall mounted rust proof, electric shock proof, termit opoof and FR grade SMC enclosure confirming to IP 54.The cercuit should also have provision for manual operation and in 3phase model,controlling current phase selection option (at least from 2 phases) complete all as specified and directed. (Make- SWADEEP (from Healer Enterprises) model - Navdeep-54-12kW3P or equivalent) |
| 27 | Material and labour in replacement 1.5 sqmm three core copper PVC insulated sheathed cable drawing into inside the Pole / bracket of street light including making hole of 15 mm dia on bottom & top complete all as specified and directed. Make : Havells Cat Part No WHMFDSKG31X5 or equivalent in Polycab/Anchor/Grandlay |
| 28 | M&L for earthing complete with galvanized steel pipe electrode 40 mm bore, medium grade 2.50 meters length, buried in ground vertically to a depth n.less than 3.75 mtr below normal ground level and connected with GI earthing wire 4 mm dia by means of bolts, nuts and washers made of galavanised iron and steel earth wire protected by 15 mm bore light grade GI pipe incl PCC work as per sketch No - 2 of SSR Part -I (2009) pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel, wire mesh 20 mm dia GI pipe medium grade for watering, charcoal and slat in alternate layers incl necessary earth work and excavation in soft/loose soil and removal etc incl testing complete all as specified and directed including tesing on completion. |
| 29 | S&F for service connection cable,1100 volt grade heavy duty PVC insulated aluminum conductor of size 10 Sq mm 2 core served with inner sheathing of PVC tape and overall PVC sheathed in service connections including taking down old complete all as specified and directed. Please Enable Macros to View BoQ information |