Educational and Research Institute Boards / Undertakings / PSU Closing in 2 days TDR #55587832

Tender For Up-Gradation/New Hybrid (Passive + Active) Power Factor Correction For 10 Nos. 11 Kv Substations, Pgimer, Chandigarh

Issued by Boards / Undertakings / PSU · Chandigarh, Chandigarh
Tender Value
4.41 Crore
Estimated cost
Bid Submission
08 Jul 2026
2 days left
EMD
8.82 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Up-Gradation/New Hybrid (Passive + Active) Power Factor Correction For 10 Nos. 11 Kv Substations, Pgimer, Chandigarh

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 26-May-2026 Pre Bid meeting notice Technical Bid 08-Jun-2026
2 08-Jun-2026 Extended for more participation Date 08-Jul-2026
3 26-May-2026 Pre Bid meeting notice Technical Bid 08-Jul-2026

BOQ

Name of Work:- Up-gradation/New hybrid (Passive + Active) Power Factor correction for 10 nos. 11 kV Substations, PGIMER, Chandigarh
Sl. No. Item Description
1Hybrid Power Factor Correction Panel
2Design, Supply, Installation, Testing & commissioning of cubicle type Semi compartmentalized floor mounted free-standing type with separation system Hybrid APFC panel. Hybrid panel should have, 433V, 50HZ, 3 phase 4 wire/3 Wire supply. Active part should be modular and have modules of 50/100 A or mentioned in specs, AHF must be intrinsic design of voltage sourced IGBT based intelligent 3-Level topology with 12 IGBT's with Programmable Microprocessor Controller to maintain Power Factor, Harmonics & Unbalancing. The passive part must be as per IS: 16636:2017 or IEC 61921 & 61439 Part -I & II (OEM Factory made) with valid temperature rise test from CPRI/ASTA-ERDA. The passive part must be as per the duly housed in epoxy powder coated 2mm thick CRCA steel sheet semi compartmentalized enclosure free standing type with all supports, accessories, switch gears, capacitors, control gears, protections, wiring, interconnections, control MCBs, controllers, reactors, etc.
3All Major components like Capacitor, Reactors, Controller, Capacitor Duty Contactor and AHF module should be of single manufacturer for better operation and maintenance practice. All capacitors should be ISI/BIS Marked with valid CML Number on each name plate. All detuned reactors shall be with CE marking and ROHS compatible, IEC-60529, Electromagnetic standard FCC 15J,Class-A IEC61000-4, ANSI IEEE Standard 519-2014 (Harmonics LIMITS) items like capacitors should have valid CPRI type tested as per the relevant IS. Hybrid Panel should be IP-42 and duly housed in epoxy powder coated 2mm thick CRCA sheet steel semi compartmentalized enclosure free standing type with all supports, accessories, switch gears, control gears, protections, wiring, interconnections, control MCBs and maintain PF,I-THD,V-THD as per IEEE 519-92 etc. as required. Also complete in all respects & having its main components as bellow along with all other standard components ,circuitry & specifications as required:
4NOTE:1) CT,VT for power factor measurement source side also consider in all panels.
5Hybrid Power Factor Correction Panel AHF(300 Amp) + (APFC) 450 KVAR
6INCOMMER
7S.I.T.C of 1 No.of 1250 A 4P Electrically Operated Drawout (EDO) type ACB with Ics=Icu=Icw=50 KA having Microprocessor based releases for overload, S/C, O/C and earth fault protection.
81 No. of Display meter with compatible RS 485 ports.
93 No.of Phase Indicating & ON-OFF LED Lights 230 V.
101 Set. of Ammeter - digital 3 Phase.
116 No. of MCB 6A-SP-10kA-C-Curve.
12BUS BARS
131600-Amps (neutral equal size) 3 phase 4 wire 415 volts 50 HZ AL bus bars with colour coded PVC heat shrinkable sleeves.
14OUTGOING
15Active Part:
16AHF 300 Amp - 1 Nos. Three Lavel Topology 12-IGBT based active technology with gate driver,interfacing,voltage sencing & control cards,heat sinks,cooling fan,current tranducers,SMPS,SSR etc.) each have following.
179 Nos. of High-speed Semiconductor fuse
183 No of 100 Amp 3P4W AHF module (3 -Level Topology ,12 IGBT Circuit)
191 No. of Programmable HMI With 7inches LED Display.
20Passive Part:
21APFC 450Kvar-1Nos. The Solution should comprise of 450kVAr including Capacitor Duty Contactor, APFC relay & Detuned filter reactors 14% with 143% linearity. The capacitor bank should have the following step ratings:100X2+50X 3+25X2+15X1+10X2+5X3 Capacitor shall be Gas impregnated Heavy Duty MPP type low loss with overcurrent capability of 1.8xIr and Inrush current capability of 400xIr.Each stage of the capacitor bank should have suitable overload and short circuit protection as defined below.
221 No APFC Relay with 3 CT sencing facilities.
23Cap Bank -100KVAR - 2 Nos. (Each Consist)
241 No. 250A 3P MCCB 25 KA with built in protection
251 No. Capacitor Duty Contactor for 100 kvar Capacitor Unit.
264 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
271 Set of start/stop PB & On/OFF LED, A/M S.S
28Cap Bank -50KVAR - 3 Nos. (Each Consist)
291 No. 125A 3P MCCB 25 KA with built in protection
301 No. Capacitor Duty Contactor for 50 kvar Capacitor Unit.
312 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
321 Set of start/stop PB & On/OFF LED, A/M S.S
33Cap Bank -25KVAR - 2 Nos. (Each Consist)
341 No. 63A 3P MCCB 25 KA with built in protection
351 No. Capacitor Duty Contactor for 25 kvar Capacitor Unit.
361 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
371 Set of start/stop PB & On/OFF LED, A/M S.S
38Cap Bank -15KVAR - 1 Nos. (Each Consist)
391 No. 32A 3P MCCB 25 KA with built in protection
401 No. Capacitor Duty Contactor for 15 kvar Capacitor Unit.
411 No. of 20KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
421 Set of start/stop PB & On/OFF LED, A/M S.S
43Cap Bank -10KVAR - 2 Nos. (Each Consist)
441 No. 25A 3P MCCB 25 KA with built in protection
451 No. Capacitor Duty Contactor for 10 kvar Capacitor Unit.
461 No. of 12.5KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
471 Set of start/stop PB & On/OFF LED, A/M S.S
48Cap Bank -5KVAR - 3 Nos. (Each Consist)
491 No. 16A 3P MCCB 25 KA with built in protection
501 No. Capacitor Duty Contactor for 7 kvar Capacitor Unit.
511 No. of 6.3KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
521 Set of start/stop PB & On/OFF LED, A/M S.S
53As Above
54Hybrid Power Factor Correction Panel AHF (250 Amp) + APFC (400 KVAR )
55INCOMMER
56S.I.T.C of 1 No. of 1250 A 4P Electrically Operated Drawout (EDO) type ACB with Ics=Icu=Icw=50 KA having Microprocessor based releases for overload, S/C, O/C and earth fault protection.
571 No. of Display meter with compatible RS 485 ports(MODBUS).
583 No. of Phase Indicating & ON-OFF LED Lights 230 V.
591 Set. of Ammeter - digital 3 Phase.
606 No. of MCB 6A-SP-10kA-C-Curve.
61BUS BARS
621600-Amps (neutral equal size) 3 phase 4 wire 415 volts 50 HZ AL bus bars with colour coded PVC heat shrinkable sleeves.
63OUTGOING
64Active Part:
65AHF 250 Amp - 1 Nos. Three Level Topology 12-IGBT based active technology with gate driver, interfacing, voltage sensing & control cards, heat sinks, cooling fan, current tranducers, SMPS,SSR etc.) each have following.
669 Nos. of High speed Semiconductor fuse
672 Nos. of 100 Amp 3P4W AHF module (3 -Level Topology ,12 IGBT Circuit)
681 No. of 50 Amp 3P4W AHF module (3 -Level Topology ,12 IGBT Circuit)
691 No. of Programmable HMI With 7inches LED Display.
70Passive Part:
71APFC 400Kvar-1Nos. The Solution should comprise of 450kVAr including Capacitor Duty Contactor,APFC relay & Detuned filter reactors 14% with 143% linearity.The capacitor bank should have the following step ratings:100X2+50X2+25X2+15X1+10X2+5X3 Capacitor shall be Gas impregnated Heavy Duty MPP type low loss as per standards with overcurrent capablity of 1.8xIr and Inrush current capability of 400xIr .Each stage of the capacitor bank should have suitable overload and short circuit protection as defined below.
721 No APFC Relay with 3 CT sencing facilities.
73Cap Bank -100KVAR - 2 Nos. (Each Consist)
741 No. 250A 3P MCCB 25 KA with built in protection
751 No. Capacitor Duty Contactor for 100 kvar Capacitor Unit.
764 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
771 Set of start/stop PB & On/OFF LED, A/M S.S
78Cap Bank -50KVAR - 2 Nos. (Each Consist)
791 No. 125A 3P MCCB 25 KA with built in protection
801 No. Capacitor Duty Contactor for 50 kvar Capacitor Unit.
812 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
821 Set of start/stop PB & On/OFF LED, A/M S.S
83Cap Bank -25KVAR - 2 Nos. (Each Consist)
841 No. 63A 3P MCCB 25 KA with built in protection
851 No. Capacitor Duty Contactor for 25 kvar Capacitor Unit.
861 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
871 Set of start/stop PB & On/OFF LED, A/M S.S
88Cap Bank -15KVAR - 1 Nos. (Each Consist)
891 No. 32A 3P MCCB 25 KA with built in protection
901 No. Capacitor Duty Contactor for 15 kvar Capacitor Unit.
911 No. of 20KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
921 Set of start/stop PB & On/OFF LED, A/M S.S
93Cap Bank -10KVAR - 2 Nos. (Each Consist)
941 No. 25A 3P MCCB 25 KA with built in protection
951 No. Capacitor Duty Contactor for 10 kvar Capacitor Unit.
961 No. of 12.5KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
971 Set of start/stop PB & On/OFF LED, A/M S.S
98Cap Bank -5KVAR - 3 Nos. (Each Consist)
991 No. 16A 3P MCCB 25 KA with built in protection
1001 No. Capacitor Duty Contactor for 7 kvar Capacitor Unit.
1011 No. of 6.3KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1021 Set of start/stop PB & On/OFF LED, A/M S.S
103As Above
104Hybrid Power Factor Correction Panel AHF (150 Amp) + APFC (250 KVAR)
105INCOMMER
1061No. 800A Amps. 415 Volts 4P Ics=Icu=Icw=50 KA Microprocessor Based Type ACB with overload, S/C, O/C and earth fault protection.
1071 No. of Display meter with compatible RS 485 ports(MODBUS).
1083 No. of Phase Indicating & ON-OFF LED Lights 230 V.
1091 Set. of Ammeter - digital 3 Phase.
1106 No. of MCB 6A-SP-10kA-C-Curve.
111BUS BARS
1121000-Amps (neutral equal size) 3 phase 4 wire 415 volts 50 HZ AL bus bars with colour coded PVC heat shrinkable sleeves.
113OUTGOING
114Active Part:
115AHF 150 Amp - 1 Nos. Three Level Topology 12-IGBT based active technology with gate driver, interfacing, voltage sensing & control cards, heat sinks, cooling fan, current tranducers, SMPS,SSR etc.) each have following.
1169 Nos. of High speed Semiconductor fuse built in protection.
1171 No of 100 Amp 3P4W AHF module (3 -Level Topology ,12 IGBT Circuit)
1181 No of 50 Amp 3P4W AHF module (3 -Level Topology ,12 IGBT Circuit)
1191 No. of Programmable HMI With 7inches LED Display.
120Passive Part:
121APFC 250Kvar-1Nos. The Solution should comprise of 450kVAr including Capacitor Duty Contactor,APFC relay & Detuned filter reactors 14% with 143% linearity.The capacitor bank should have the following step ratings:50X3+25X2+15X1+10X2+5X3 Capacitor shall be Gas impregnated Heavy Duty MPP type low loss as per standards with overcurrent capablity of 1.8xIr and Inrush current capability of 400xIr .Each stage of the capacitor bank should have suitable overload and short circuit protection as defined below.
1221 No APFC Relay with 3 CT sencing facilities.
123Cap Bank -50KVAR - 3 Nos. (Each Consist)
1241 No. 125A 3P MCCB 25 KA with built in protection
1251 No. Capacitor Duty Contactor for 50 kvar Capacitor Unit.
1262 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1271 Set of start/stop PB & On/OFF LED, A/M S.S
128Cap Bank -25KVAR - 2 Nos. (Each Consist)
1291 No. 63A 3P MCCB 25 KA with built in protection
1301 No. Capacitor Duty Contactor for 25 kvar Capacitor Unit.
1311 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1321 Set of start/stop PB & On/OFF LED, A/M S.S
133Cap Bank -15KVAR - 1 Nos. (Each Consist)
1341 No. 32A 3P MCCB 25 KA with built in protection
1351 No. Capacitor Duty Contactor for 15 kvar Capacitor Unit.
1361 No. of 20KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1371 Set of start/stop PB & On/OFF LED, A/M S.S
138Cap Bank -10KVAR - 2 Nos. (Each Consist)
1391 No. 25A 3P MCCB 25 KA with built in protection
1401 No. Capacitor Duty Contactor for 10 kvar Capacitor Unit.
1411 No. of 12.5KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1421 Set of start/stop PB & On/OFF LED, A/M S.S
143Cap Bank -5KVAR - 3 Nos. (Each Consist)
1441 No. 16A 3P MCCB 25 KA with built in protection
1451 No. Capacitor Duty Contactor for 7 kvar Capacitor Unit.
1461 No. of 6.3KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1471 Set of start/stop PB & On/OFF LED, A/M S.S
148As Above
149Hybrid Power Factor Correction Panel AHF (150 Amp) + APFC (200 KVAR )
150INCOMMER
1511 No. of 630A Amps. 415 Volts 4P Microprocessor Based Type ACB of 50KA with overload, S/C, O/C and earth fault protection.
1521 No. of Display meter with compatible RS 485 ports.
1533 No. of Phase Indicating & ON-OFF LED Lights 230 V.
1541 Set. of Ammeter - digital 3 Phase.
1556 No. of MCB 6A-SP-10kA-C-Curve.
156BUS BARS
157800-Amps (neutral equal size) 3 phase 4 wire 415 volts 50 HZ AL bus bars with colour coded PVC heat shrinkable sleeves.
158OUTGOING
159Active Part:
160AHF 150 Amp - 1 Nos. Three Level Topology 12-IGBT based active technology with gate driver, interfacing, voltage sensing & control cards, heat sinks, cooling fan, current tranducers, SMPS, SSR etc.) each have following.
1619 Nos. of High speed Semiconductor fuse built in protection.
1621 No of 100 Amp 3P4W AHF module (3 -Level Topology ,12 IGBT Circuit)
1631 No of 50 Amp 3P4W AHF module (3 -Level Topology ,12 IGBT Circuit)
1641 No. of Programmable HMI With 7inches LED Display.
165Passive Part:
166APFC 200Kvar-1Nos. The Solution should comprise of 450kVAr including Capacitor Duty Contactor,APFC relay & Detuned filter reactors 14% with 143% linearity.The capacitor bank should have the following step ratings:50X2+25X2+15X1+10X2+5X3 Capacitor shall be Gas impregnated Heavy Duty MPP type low loss as per standards with overcurrent capablity of 1.8xIr and Inrush current capability of 400xIr .Each stage of the capacitor bank should have suitable overload and short circuit protection as defined below.
1671 No APFC Relay with 3 CT sencing facilities.
168Cap Bank -50KVAR - 2 Nos. (Each Consist)
1691 No. 125A 3P MCCB 25 KA with built in protection
1701 No. Capacitor Duty Contactor for 50 kvar Capacitor Unit.
1712 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1721 Set of start/stop PB & On/OFF LED, A/M S.S
173Cap Bank -25KVAR - 2 Nos. (Each Consist)
1741 No. 63A 3P MCCB 25 KA with built in protection
1751 No. Capacitor Duty Contactor for 25 kvar Capacitor Unit.
1761 No. of 33.1KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1771 Set of start/stop PB & On/OFF LED, A/M S.S
178Cap Bank -15KVAR - 1 Nos. (Each Consist)
1791 No. 32A 3P MCCB 25 KA with built in protection
1801 No. Capacitor Duty Contactor for 15 kvar Capacitor Unit.
1811 No. of 20KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1821 Set of start/stop PB & On/OFF LED, A/M S.S
183Cap Bank -10KVAR - 2 Nos. (Each Consist)
1841 No. 25A 3P MCCB 25 KA with built in protection
1851 No. Capacitor Duty Contactor for 10 kvar Capacitor Unit.
1861 No. of 12.5KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1871 Set of start/stop PB & On/OFF LED, A/M S.S
188Cap Bank -5KVAR - 3 Nos. (Each Consist)
1891 No. 16A 3P MCCB 25 KA with built in protection
1901 No. Capacitor Duty Contactor for 7 kvar Capacitor Unit.
1911 No. of 6.3KVAR MPP-H capacitor at 525 V AC with 14% AL wound Detuned Reactor.
1921 Set of start/stop PB & On/OFF LED, A/M S.S
193As Above
194Supplying of following size of XLPE insulated , PVC sheathed cable of 1.1 kV grade , aluminium conductor, flat steel strip armoured,comforming to IS: 7098 (Part 2) with upto date ammendment complete as required.
1953.5C X 400 sq. mm
196Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
197Above 185 sq. mm and upto 400 sq. mm
198Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
199Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
200Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.
2013.5C X 400 sq. mm
202LT 1.1 kV CONTROL CABLES
203Supplying of following sizes of 1.1 kV grade PVC insulated copper conductor armoured stranded Control Cable conforming to IS :1554 complete as required and as per specifications.
2046 core, 2.5 Sq.mm. Cu. Conductor cable
205Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
206Upto 35 sq. mm (clamped with 1mm thick saddle)
207Supplying and making end termination with double brass compression gland and Copper lugs for following size of PVC sheathed copper conducter armoured control cable of 1.1 kV grand as required.
2086 C x 2.5 Sq.mm.
209Supply , Installation, Testing and commissioning of following rating Acb's in the spare compartment of existing LT Panels at various locations including fabrication, connection with solid bus bar, etc. as required
2102 -Nos. ACB, EDO Type 1250 Amps, 50 kA, 4 Pole, Microprocessor Based . SITC of Indicator RYB, On,Off,trip, current transformer, CT shorting Terminals, MCB , Neutral Link, Auxiliary Contractor, Terminal Blocks, Wiring for feeder, Busbar Link for ,etc as required at site.
2114-Nos. of 800A 4P ACB with Ics=Icu=Icw 50 KA having Mircroprocessor based releases for O/L, S/C & E/F. SITC of Indicator RYB, On,Off,trip, current transformer, CT shorting Terminals, MCB , Neutral Link, Auxiliary Contractor, Terminal Blocks, Wiring for feeder, Busbar Link for ,etc as required at site.
212Each ACB shall have one set of the following items:
213Intelligent multi function digital meter Datalog (8 MB),Analog I/O, digital I/O variants available, Meter with Ethernet port available Parameters: V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts,Phase angle, THD, Neutral current, Max Demand (with RTC), Events (high-low) with time stamp,Individual Harmonics upto 31st.
214All ACBs shall have Icu=Ics=Icw for 1.0 secs for all ACBs
2151 Set Indication Lamps, LED type, for RYB with2 Amp control MCB.& breaker 'ON', 'OFF', 'TRIP' & spring charged lamps with 2 Amp MCB for controlling alonwith SITC of TNC switch.
216As Above upto the entire satisfaction of Engineer-in -Charge
217Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
218Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
219Add GST @6.33%
220Less Rebate on following materials after de-termination and dismantling from existing panel including transportation from PGI.
221500KVAR APFC Panel at ACC SS & ATC SS
222480KVAR APFC Panel at NHE SS
223250 KVAR APFC Panel at APC SS & AEC SS
224175 KVAR APFC Panel at Emergency SS
225150 KVAR APFC Panel at MDH SS Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55587832
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 4.41 Crore
LAST DATE 08-07-2026
Authority
Authority Name Post Graduate Institute Of Medical Education And Research
Work Description Tender for Up-Gradation/New Hybrid (Passive + Active) Power Factor Correction For 10 Nos. 11 Kv Substations, Pgimer, Chandigarh
Basic Detail
Tender No PGI/Engg./Elect./2026-27/07
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 08 Jun 2026
Submission Date 08 Jul 2026
Open Date 09 Jul 2026
Finance
Tender Value 4.41 Crore
Tender Fee Ref. Documents
EMD 8.82 Lakhs
Exemption Available
Document List
BOQ_955824.xls
d73d2ef8-936d-46e6-a237-e92980f7cb59.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 08, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 08, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 08, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_955824.xls

html

d73d2ef8-936d-46e6-a237-e92980f7cb59.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders