| 1 | SITC of Decorative Street Light |
| 2 | OD344856/2025-2026:Supply conveyance installation, testing and commissioning of Decorative Pole 6 metre heightabove the ground level made out of GI, pipe section with die cast aluminium embellishmentsincluding connector 16mm diameter (4 numbers) foundation bolts of 450mm bolt length,200mm pitch circle diameter manufactured from special steel along with nuts, washers, anchorplate foundation bolt 4 nos fixed in existing RCC foundation. The poles shouldhave diameter of 114mm to 140mm at the bottom minimun 2000 mm length 60mm to 90mm atthe middlle minimum 3000 mm length and 40mm to 50mm at top minimum 1000mm length.The pole should should be pure polyester based powder coated with high corrosion resistanceand chemical chromatised protection. The base should be made of die cast MS with holessuitable for 16/20/24 mm foundation bolts including supply and fixing Hot Dipped Galvanisedsingle arm decorative bracket (Model No: Crompton HM DECO SA NS) tightened to the poleto mount the luminaries etc as required shall be incorporated. The pole shall be with inbuiltjunction looping box at bottom section with 32 A heavy duty 4 way connector for loop in andloop out and 1 no 6 A SP MCB and with MS base plate. The pole shall be suitable for windloading and as per IS 875 part 3 1987: ( Make Crompton Voila HM-DECO/ K lite Enigma/PelicanOrion /Keslec technically equivalent) |
| 3 | OD344857/2025-2026:SITC of LED Decorative Classic luminaire of system wattage 60 W suspended typeasymmetrical light distribution Clear acrylic/poly carbonate diffuser with minimum 425mmdiameter , BIS certified with a body and frame of high pressure die cast aluminum, separateoptical and control gear compartment accessed by opening four screws at the top of theluminaire, a vent pressure equalization unit and pre-cabled as required. Theluminaire shall have ingress protection of IP65. Highly efficient temperature resistant lenses forlight distribution with several optical options providing excellent photometry to optimally caterto different applications. Overall system efficiency of minimum 125lm/W at correlated colourtemperature (CCT) 3000K (WW), rated lifetime of 50,000 hours. Electrical Class I, ratedvoltage 240V AC , Power Factor >0.95, with BIS certified potted driver having internal surgeprotection of minimum 6 kV . ( Crompton Empire WW/K lite Pelican Fort Mini 4897 WWLED/ Kesslec Porto NU WW with opal shallow PMMA protector ). |
| 4 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 5 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 6 | OD344855/2025-2026:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 8 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 9 | 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 10 | OD344854/2025-2026:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing RCC/HUME/STONE WVRE/GI/DWC pipe as required.2 core 16 sq mm |
| 11 | 9.1.3:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm) |
| 12 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 13 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 14 | OD29319/2026-2027:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 40/32 mm or nearest size |
| 15 | OD29320/2026-2027:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 40/32 mm or nearest size |
| 16 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 17 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 18 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 19 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 20 | 90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 21 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 22 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 23 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 24 | OD344846/2025-2026:Supply and fixing Time switch 240V AC DIN/BASE mounting -Analog version in the existing enclosure and giving connection as required. |
| 25 | OD344849/2025-2026:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactorconforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required- |
| 26 | OD344847/2025-2026:Supply and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board |
| 27 | OD344848/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board |
| 28 | 90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 29 | 90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class) |
| 30 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 31 | OD344844/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.25 mm X 3 mm G.I. strip |
| 32 | OD344845/2025-2026:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip |
| 33 | OD344851/2025-2026:Supply and fixing 32 mm dia 6Kgff/cm2 PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required (For Service Pipe) Please Enable Macros to View BoQ information |