| 1 | Receiving complaints from JE incharge lodged by the user/ occupants of security/ street light / concern external electric supply nature, rectification of the fault as detailed by JE incharge/ AGE E/M to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismentled complete all as directed at site to the entire satisfaction of department.Note : (i) Any copmplaint which is left out/unattendent 1-2 days by the electrician by any reasons the same to be communicated to the JE incharge /AGE E/M with reason.(ii) New material/stores provided for completing the job shall be measured and paid for separetely under relevent items of sch 'A'.(iii) Contractor shall provide the all type of T&P to each electrician for attending the internal electric complaints. (iv) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate as per sample. The rate of such items included in this items.(v) Any unattended complaints not done in specified time limit, the contractor shall be peanalised with Rs. 200/- per each complaints per day. |
| 2 | Supply only energy efficient LED Street / Roadway with PDC housing luminaire, high PF, 60W, energy saving and environmental friendly long life versatile pressure die cast aluminium housing, clear toughned glass, IP 66 protection, 240 Volts, 120 lumens/Watt, colour temp. 6500K, complete all as specified and directed. |
| 3 | Supply only LED outdoor drivers, suitable for 36-45 Watt street light fitting all as specified and directed. |
| 4 | Supply only LED outdoor drivers, suitable for 50-80 Watt street light fitting all as specified and directed. |
| 5 | Supply only LED outdoor drivers, suitable for 90-150 Watt street/flood light fitting all as specified and directed. |
| 6 | Supply only LED outdoor drivers, suitable for 160-200 Watt flood light fitting all as specified and directed. |
| 7 | Supply only energy efficient LED Street / Roadway with PDC housing luminaire, high PF, 70-72W, energy saving and environmental friendly long life versatile pressure die cast aluminium housing, clear toughned glass, IP 66 protection, 4kV inbuilt surge protection, 240 Volts, 120 lumens/Watt, colour temp. 5700K, complete all as specified and directed. |
| 8 | Supply only Alpha Rex3 digital time switches D-22, multifunctional digital time switches all as specified and directed. |
| 9 | Supply only power contactors ML-3, 3 pole rating not less than 40 Amp, 230 coil complete as specified and directed. |
| 10 | Supply only timelite distribution board digital time switch 65 Amp, 3 pole 230 Volts complete including Contactor and Digital type time switch. |
| 11 | Supply only energy efficient LED Flood light Luminaire, high PF, 100W, energy saving and environmental friendly long life versatile pressure die cast housing IP 66 protection, 240 Volts, bracket of adequate size, complete including testing & commissioning. |
| 12 | Supply only Decorative LED post top lantern, high PF, 40 Watt, energy saving and environmental friendly long life versatile pressure die cast aluminium housing, 360 degree indirect light, optimum light output, IP 65 protection, glare-free and better uniformty, 240 Volts complete all as specified and directed. |
| 13 | Supply only brackets made out of 40mm bore GI pipe, light grade, 1.5 m long, bend to shape and including suitable GI clamps made out of 40x6mm flat iron, necessary GI bolts, nuts, washers etc complete all as specified and directed. |
| 14 | Supply only PVC weather proof, hinged door, junction box of size 250x200x100mm with 240 Volts, Neutral link and 1 No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc. complete all as specified and directed. |
| 15 | Supply only LED flood light maximum 180W, minimum system lumen output of 22000 lm. The luminnare should have colour temperature of 5700/ 6500K and THD<10% CRI> 70. The luminaire shall meet IP66 ingress protection and impact resistance of IK07 and luminaire housing should made of pressure die-cast aluminium and itegrated PC Lens. The luminaire should have the features of high Voltage 10 kV external surge protection long life, integrated potted LED driver offers comfortable softlight, high durability, driver safety requirement standards as per IS 15885-2 -13. |
| 16 | Supply only LED bush light of capacity 12 Watt, 240 Volts with die cast aluminium housing with toughned glass, IP-66 complete all as specified and directed. |
| 17 | Supply only LED aviation light fitting with comprising of aluminium housing with polycarbonate enclosure, IP 66 protection complete all as specified and directed. |
| 18 | Supply only Solar LED security light of capacity 50 Watt, integrated all in one type inbuilt solar charge controller, solar PV module, Life PO4 battery and mounting clamps as a ready installation having following specifications:-- SEC/MNRE tested approved PV panel and battery.- Operating voltage : 12.8V DC.- Battery type: 12.8V 30 Ah Lithium Ferro Phosphate (Li-FePO4) BIS certified.- System Wattage 12.8V, 50 Watt LED luminaire integrated with street light made of aluminium extrusion and CRCA powder coated sheet with inbuilt charge controller.- Lumen efficacy : Not less than 120 lm/Watt.- CCT : 5400K - 6000K.- CRI : Polycarbonate lenses LED.- PV module : Mono-crystalline 100Wp PV module under STC equivalent MNRE/SEC tested.- Mounting bracket : included.- Dimming level : PIR motion sensor based dimming - 100% once motion detected and rest time operate at 30 % load.- PIR motion sensor : Inbuilt.- Duty cycle : After dusk on 12 hrs/day as per dimming level.- Automony : 1 day as per duty cycle per day at battery full charge STC condition.- Protection : Overcharge, Deep discharge, reverse polarity, overload. |
| 19 | S&F LED tri-colour light, column 3 m height with die-cast aluminium housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage and IP 65 protection with tratic white output switch (bollard light fitting) complete including fixing on PCC 1:2:4 foundation of adequate size and taking down old light fitting complete all as specified and directed. |
| 20 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed. |
| 21 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 22 | Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 23 | Supply, fix, laying or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 2 core 6 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning including taking down old cable complete all as specified and directed. |
| 24 | All as per SI item No 23 above, but for 2 Core 10 Sqmm. |
| 25 | All as per SI item No 23 above, but for 4 Core 16 Sqmm. |
| 26 | All as per SI item No 23 above, but for 4 Core 25 Sqmm. |
| 27 | M&L for double walled corrugated (DWC) HDPE pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and directed. Please Enable Macros to View BoQ information |
| 28 | M&L for double walled corrugated (DWC) HDPE pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and directed. Please Enable Macros to View BoQ information |