| 1 | List of Works |
| 2 | Total amount of Sch 'A' part-I ( Buildings/ Structures) |
| 3 | Total amount of Sch 'A' part-II (Excavation, Earthwork, & Site Development) |
| 4 | Total amount of Sch 'A' part-III ( Retaining Wall ) |
| 5 | Total amount of Sch 'A' part-IV (Internal water supply) |
| 6 | Total amount of Sch 'A' part-V ( Internal Electric Supply) |
| 7 | Total amount of Sch 'A' part-VI ( External Water Supply) |
| 8 | Total amount of Sch 'A' part-VII (External Electric Supply ) |
| 9 | Total amount of Sch 'A' part-VIII ( Lightning Protection & Aviation Obstruction Light ) |
| 10 | Total amount of Sch 'A' part-IX (Area Drainage ) |
| 11 | Total amount of Sch 'A' part-X (Sewage Disposal ) |
| 12 | Total amount of Sch 'A' part-XI (Road , Path & Culvert ) |
| 13 | Total amount of Sch 'A' part-XII ( Lift) |
| 14 | Total amount of Sch 'A' part-XIII ( Rain Water Harvesting ) |
| 15 | Total amount of Sch 'A' part-XIV (Arboriculture ) |
| 16 | Total amount of Sch 'A' part-XV (Fencing & Gates ) |
| 17 | Total amount of Sch 'A' part-XVI (Hot Water Supply ) |
| 18 | Total amount of Sch 'A' part-XVII (DG Set) |
| 19 | External Water Supply/ ARBORICULTURESupply and laying and testing & commissioning of DI pipes 150mm bore centrifugally cast, internally cement mortar lining external zinc coating with finishing layer of bitumen, pressure pipe socket and spigot end confirming to IS 8329-2000 with ISI marked K-9 in standard length including necessary rubber gasket, tyron jointings, Jointing material complete all as specified and as directed.Make- Jindal, Electro Therm, Jindal saw, Electro Steel. |
| 20 | M&L for construction of brick masonnary with full brick wall chamber size of 900x900x900mm internal diemension with earth work on any type of soil , PCC M-10 type C-2 as in foundation , brick work in CM1:4, 15mm thick plaster in CM1:4 internaly and externally , flush pointed in same mortar as work proceeds , 75mm thick PCC coping all around (M-15 with 20mm aggregate ) , flooring shall 40mm thick PCC M-15 (Nominal Mix ) laid over 75mm thick hard core. Top cover shall be made out of PVC 5mm thick fixed in angle iron frame made out of angle iron size 40x40x6mm with two numbers of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed including demolation of old existing Abandoned valve pits. |
| 21 | Cutting of existing CI/DI pipe line of 150 mm bore for insertion of 150x150x150 mm Tee in portion including required fittings and excavation and earth work complete all as specified and directed. |
| 22 | SHRUBS : Digging pits of size 0.6 x 0.6 x 0.6 M, removal of debris, weed roots etc. refilling with good soil and cattle manure in 4:1 ratio, provn of anti-termite treatment at plantation time including supply of planting of approved species of healthy grown up sapling with good root system and minimum 2 feet height from ground level after plantation.(Bougainvillea, Song of India, dracaena, Ixora, Tecoma, Nerium red etc.) Maint : including watering, loosening of soil fortnightly, manuring with fertilizer, trimming, pruning, stacking and spraying of insecticide as and when required. Clearing of any type of vegetation in and around the plantation area for a period upto DLP complete all as specified and as directed. |
| 23 | LAWN : Loosening of soil, removal of weed roots etc. refilling with good soil and cattle manure in 4:1 ratio, provn of anti-termite treatment at plantation time mixing, levelling and planting of deep Mexican grass and maint for a period upto DLP complete all as specified and as directed. |
| 24 | M&L for construction of brick masonnary with full brick wall chamber size of 900x900x900mm internal diemension with earth work on any type of soil , PCC M-10 type C-2 as in foundation , brick work in CM1:4, 15mm thick plaster in CM1:4 internaly and externally , flush pointed in same mortar as work proceeds , 75mm thick PCC coping all around (M-15 with 20mm aggregate ) , flooring shall 40mm thick PCC M-15 (Nominal Mix ) laid over 75mm thick hard core. Top cover shall be made out of PVC 5mm thick fixed in angle iron frame made out of angle iron size 40x40x6mm with two numbers of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed including demolation of old existing Abandoned valve pits. |
| 25 | Internal Electric SupplyPoint wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) With multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc. ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sq. mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for One light/ Ceiling fan /exhaust fan/Bell point controlled by one 5/6 amps one way switch. |
| 26 | All as per Item No. 24 but for One Socket outlet, three/ five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin all as directed and specified. |
| 27 | All as per Item No. 24 but for One light point controlled by 2 Nos, Two Way switches 5/6 Amps all as directed and specified. |
| 28 | Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) With multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc. ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 2.5 Sq. mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent. |
| 29 | TV socket coaxial, I Module with GI flush box, inner and outer plate complete all as directed and specified. |
| 30 | Telephone socket coaxial, I Module with GI flush box, inner and outer plate complete all as directed and specified. |
| 31 | TV socket outlet modular type 1 model Make-Legrand or equivalent complete all as directed and specified. |
| 32 | RJ 11 Telephone socket modular type 1 module Make-Legrand or equivalent complete all as directed and specified. |
| 33 | External Electric SupplySupply, install, testing and commissioning of transformer step down HT 11KV/433V, plinth/platform mounted out door type copper wound with necessary standard fitting of capacity 100KVA , three phase, 4 wire 50 cycles, oil immersed, naturally cooled with external cooling tubes, core type, delta connected on primary (HV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tapping's in equal steps of 2.5% from (+/-)2.5% to (+/-) 5% on primary side by means of hand operated off load tap changing gear, so as to vary LT voltage on secondary side including provision of all necessary/ standard fittings all as per IS-1180:2014 with energy efficient level-2 complete including PCC block work masonary foundation of size 1.5m x 1.5m x 1.2m above ground level over 1.9x1.9x0.2m PCC footing using 1:2:4 using 40mm stone aggregate duly rendered and pcc coping 10cm thick of 1:2:4 using 20mm stone aggregate on top of foundation suitable for mounting transformer with max in allowable losses 50% load 392 Watts and at 100% load 1365 watts complete all as specified and directed and mainly comprising of :-.(a) One Cable box on HV side with one set of 11KV HT bushing with brass/gun metal bushing rods complete with nuts and washers. |
| 34 | (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings with GM bushing rods complete with GM nuts and washers with one Nos cable gland suitable for reception of outgoing LT XLPE cable of 120 sqmm , 3.5 core.(c ) Oil conservator with filter type, drain valve and oil level gauge.(d) Silica gel dehydrating breather with first fill of silica gel.(e) Explosion vents.(f) Thermometer pocket on tank cover.(g) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting devices.(h) Rating plate with terminal markings.(j) Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6mm GI earth strip.(k) Oil level gauge.(l) Oil drain and filter valves.(m) Oil filler hole with cap/plug .(n) Lifting lugs/hooks fitted with body.(o) Air relief valve plug.(p) Four plain solid cast steel detachable rollers.(q) First fill of fresh oil conforming to relevant IS and tested upto 50 KV dielectric strength.(r) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral. |
| 35 | Supply install testing and commissioning of HT 11 KV, 3 Phase, 50 Hz,totally 11kV, 630A, 21kA/3sec, 3Way Outdoor, Extensible motorized SCADA compatible RMU as per MSEDCL specification consisting of 2Nos. feeder with Load Break Switch and 1No. feeder with VCB. | - Qty.-1No. Each Incomer feeder with Switch consists of: 1. Motorised 630A load breaker switch with built-in earth switch with full making capacity. 1 No. 2. Mechanical position indicator. Switch ON/OFF/EARTHED. 1 No. 3. Live Cable Indication. 1 No. 4. Cable compartment cover interlocked with earth switch. 1 No. 5. Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable. 3 No. 6. 7. 8. Cable termination cover boots (Push on type) NO/NC contact for Isolator ON/OFF , Earth Switch ON/OFF , Fault Indicator Operated Command Output for: Isolator Close, Isolator Open , FPI reset 1 Set. 1 Set. 1 Set. Each Outgoing VCB feeder consists of: 1. Motorised 630A Vacuum Circuit Breaker with manual spring charging arrangement and manual close & open push buttons, ON / OFF indication and series trip coil for self powered relay & shunt trip coil for external tripping. 1 No. |
| 36 | 2. Self powered Numerical O/C & E/F relay with CTs. 1 Set 3. Manually operated 630A disconnector with built-in earth switch. 1 No. 4. Mechanical position indicator. Switch ON/OFF/EARTHED. 1 No. 5. Live Cable Indication. 1 No. 6. Cable compartment cover interlocked with earth switch. 1 No. 7. Cable termination bushings suitable for 1no. 3CX300mm2 XLPE cable. 3 No. 8. 9. Cable termination cover boots (Push on type) NO/NC contact for: Breaker ON/OFF, Relay operated. 1 Set. 1 Set. 1no. Metering Module as Bus PT 1 Set of 03nos. Single Phase Potential Transformers having ratio 11kV/rt3:110V/rt3, 50VA, Class 0.5 1 Provision for installation of Multifunction Meters for energy reading in breaker functions. Common Items per RMU , SF6 Gas Pressure indicator with auxiliary contacts. 1 No. Handles for RMU - 2Nos. Fault Passage Indicator with associated CT’s. Battery & Battery Charger. 500VA Auxiliary Transformer complete all as specified and as directed. |
| 37 | Supply, installation ,commissioning and testing of LT fedder pillar 415 Volts, 3 Phase ,50 Hz Outdoor type factory made, hinged double door ,with door open upto 150 degree when swung and doors should automatically come to closed position if not kept open with effort , aldrop bolt locking arrangemnets of size suitable to accommodate the following accessories, however the depth of panel board shall not be less than 500 mm, made out of 3 mm thick MS sheet , CRCA sheet inside 2 mm thick total modular type fabrication with 7 tanks process, IP-54 with coloured insulation sleeve, rubber, insulator outdoor type totally enclosed weather dust and vermin proof as per IS with front opening suitable arrangement having aluminium bus bar of 400 amps capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 65 x 65 x 6 mm angle iron grouted at ground above 30 cm from ground level. Comprising complete all as specified with the following accessories. |
| 38 | Note:1). Cost including necessary internal connection from bus bar to MCCB/MCB connections. 2) GD Drawing for LT feeder pillar should be get approved from Engineer in charge before fabrication. (a) MCCB 250 Amp 4 pole 36 kA - 01 No. as incoming Make: Legrand/ABB/Schneider (b) MCCB 200 Amp 4 pole 25 kA - 01 Nos. as outgoing Make: Legrand/ABB (c) MCCB 63 Amp 4 pole 25 kA - 01 Nos. as outgoing Make: Legrand/ABB (d) Multification Meter Make L&T/ Legrand/Schneider (e) Phase indication lamps 01 Set (f) Bus bar min 400 Amp Aluminium with R/Y/B coulored for three phases and 200 Amp for Neutral Black colour insulation sleeves - 01 Set. Location: Near Transformer. |
| 39 | Supply, installation ,commissioning and testing of LT fedder pillar 415 Volts, 3 Phase ,50 Hz Outdoor type factory made, hinged double door ,with door open upto 150 degree when swung and doors should automatically come to closed position if not kept open with effort , aldrop bolt locking arrangemnets of size suitable to accommodate the following accessories, however the depth of panel board shall not be less than 500 mm, made out of 2.90 mm thick MS steel sheet , CRCA sheet inside 2 mm thick total modular type fabrication with 7 tanks process, IP-54 with coloured insulation sleeve, rubber, insulator outdoor type totally enclosed weather dust and vermin proof as per IS with front opening suitable arrangement having aluminium bus bar of 400 amps capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 65 x 65 x 6 mm angle iron grouted at ground above 30 cm from ground level. Comprising complete all as specified with the following accessories. |
| 40 | Note:1). Cost including necessary internal connection from bus bar to MCCB/MCB connections. 2) GD Drawing for LT feeder pillar should be get approved from Engineer in charge before fabrication. (a) MCCB 200 Amp 4 pole 25 kA - 01 No.as incomingMake: Legrand/ABB/Schneider (b) MCCB 160 Amp 4 pole 35 kA - 01 Nos.as outgoing(InLiving)Make: Legrand/ABB/ Schneider (c) MCCB 100Amp 4 pole 25 KA -01 nos for Electric water heater (d) MCCB 63 Amp 4 pole 25KA - 01 Nos. as outgoing (Dining Hall and cook House) Make: Legrand/ABB (e) MCCB 32 Amp 4 pole 25KA - 01 Nos. as outgoing (Parking Shed) Make: Legrand/ABB (f) MCB TPN 40 Amp 4 pole - 02 Nos. as outgoing(Street light and spare ) Make: Legrand/ABB (g) Multification Meter Make L&T/ Legrand/Schneider (h) Phase indication lamps 01 Set (j) Bus bar min 400 Amp Aluminium with R/Y/B coulored for three phases and 200 Amp for Neutral Black colour insulation sleeves - 01 Set. Location: Near Living accn |
| 41 | S&F new 6 mtr height hot deep galavanized steel pole hexagonal/octagonal cross sections gradeS355JO of dimensions top dia70mm bottom dia 130mm, sheet thickness 3mm, base plate dimensions 200 x 200x 12mm foundation bolt size 4 nos x 20mm dia, pitch circle dia 200mm, bolt length 600mm, proijected bolt length 100mm, anchor plate thickmess 3mm with inbuilt compartment for mounting of switch box, earthing etc covered with hinged door confirming to IS:2629/BS EN ISO1461 alongwith connector R,Y,B&N-63 Amp capacity 01 no. with MCB SP 6Amp-01 no. complete all as specified and as directedNote - Earth work and PCC foundation will be measured and paid separately. |
| 42 | S&F New 90 watt street light fittings, high efficiency IP-66 protection, powder coated, pressure die cast, aluminium housing and clear injection moulded poly carbonate / toughned glass have multi chip on board LED and metal clad PCB fixing to new bracket including nut bolts, 2.5 Sqmm 3 core cable and electrically connected complete all as directed with minimum lumen efficacy 120 lm/watt with inbuilt Internal & External surge protection. |
| 43 | M&L for Street light bracket made from MS tubing as required size at site cut to length bent to shape required and suitable for existing street light pole including painting with enamled paint two coat on one coat of primer complete all as specifed. |
| 44 | S&F new 3 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable drawn through existing conduit pipe from junction box to fitting complete all as specified and as directed. |
| 45 | S&F bollard light fittings16x 0.5W LED minimum cone series IP-65 protection dia cast aluminium housing froasted poly carbonate diffuser matt grey finish 90V-260V AC warm white with inbuilt LED Make- Jaquar/Wipro/Havells/Bajaj |
| 46 | S&F 45W IP 65 decorative LED outdoor post top lighting fixture with powder coated pressure die cast aluminum housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimun Lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket fixed as per manufacturers instructions and making neccessary electrical connections and testing on completion complete all as directed. Make : Bajaj BGCTN 45W LED WW or Schreder 40W or Panasonic APT010404. |
| 47 | LIGHTNING Supply, installation, commis-sioning of Water cooler of capacity 40 cooling capacity and 80 litre storage capacity fully stainless steel, electric driven single phase having approx storage and nominal coolingcapacity as shown. |
| 48 | SUMMER APPLIANCESupply, installation, commis-sioning of Water cooler of capacity 40 cooling capacity and 80 litre storage capacity fully stainless steel, electric driven single phase having approx storage and nominal coolingcapacity as shown. |
| 49 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA |
| 50 | REFG & ACS&F 5 star rated Split Air conditioning unit Inverter type of capacity 1.5 TR consisting of outdoor unit with fan motor, hermetically sealed rotary type compressor with complete accessories and condensing unit of copper tubing complete duly connected with separately erected indoor unit with blower motor, plasma filter, inbuilt air ioniser, insulated copper tubings (suction line & liquid line) upto 5 metre suitable for 1.5 TR AC, PVC insulated and FR PVC round sheathed multistranded copper conductor flexible cable 2.5 sqmm 3 core 1100 Volts (ISI marked) upto 5 metre, including MS Stand duly powder coated painted, Gas charging, internal copper wiring, remote control complete including making opening in stone/ brick wall by cutting, drilling for placing ducts, pipes etc and making good the disturbed surfaces of wall as per its original specification including mounting brackets for wall/ stand to rest on slab etc, AC installed as per manufacturer’s instructions and testing on completion to entire satisfaction of Engineer-in-charge complete all as directed. |
| 51 | S&F 5 star rated Split Air conditioning unit Inverter type of capacity 2.0 TR consisting of outdoor unit with fan motor, hermetically sealed rotary type compressor with complete accessories and condensing unit of copper tubing complete duly connected with separately erected indoor unit with blower motor, plasma filter, inbuilt air ioniser, insulated copper tubings (suction line & liquid line) upto 5 metre suitable for 2.0 TR AC, PVC insulated and FR PVC round sheathed multistranded copper conductor flexible cable 2.5 sqmm 3 core 1100 Volts (ISI marked) upto 5 metre, including MS Stand duly powder coated painted, Gas charging, internal copper wiring, remote control complete including making opening in stone/ brick wall by cutting, drilling for placing ducts, pipes etc and making good the disturbed surfaces of wall as per its original specification including mounting brackets for wall/ stand to rest on slab etc, AC installed as per manufacturer’s instructions and testing on completion to entire satisfaction of Engineer-in-charge complete all as directed. Please Enable Macros to View BoQ information |
| 52 | S&F 5 star rated Split Air conditioning unit Inverter type of capacity 2.0 TR consisting of outdoor unit with fan motor, hermetically sealed rotary type compressor with complete accessories and condensing unit of copper tubing complete duly connected with separately erected indoor unit with blower motor, plasma filter, inbuilt air ioniser, insulated copper tubings (suction line & liquid line) upto 5 metre suitable for 2.0 TR AC, PVC insulated and FR PVC round sheathed multistranded copper conductor flexible cable 2.5 sqmm 3 core 1100 Volts (ISI marked) upto 5 metre, including MS Stand duly powder coated painted, Gas charging, internal copper wiring, remote control complete including making opening in stone/ brick wall by cutting, drilling for placing ducts, pipes etc and making good the disturbed surfaces of wall as per its original specification including mounting brackets for wall/ stand to rest on slab etc, AC installed as per manufacturer’s instructions and testing on completion to entire satisfaction of Engineer-in-charge complete all as directed. Please Enable Macros to View BoQ information |