| 1 | Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc. |
| 2 | M&L for point wiring with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green . |
| 3 | For one light point or fan point controlled by one switch all as directed by Engr-in-charge. |
| 4 | For one Call Bell point controlled by one push button switch all as directed by Engr-in-charge. |
| 5 | For 5Amp independent socket point controlled by one switch all as directed by Engr-in-charge. |
| 6 | For one 3 pin ,5 Amp socket point with other switch on the same board all as directed by Engr-in-charge. |
| 7 | All as per item No 2 here in before but for power point wiring using with 2.5 sqmm PVC FRLSH insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green . |
| 8 | M&L for concealed point wiring with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, , including of junction and terminal boxes, all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green . |
| 9 | For one light point or fan point controlled by one switch all as directed by Engr-in-charge |
| 10 | For one Call Bell point controlled by one push button switch all as directed by Engr-in-charge |
| 11 | For 5Amp independent socket point controlled by one switch all as directed by Engr-in-charge |
| 12 | For one 3 pin ,5 Amp socket point with other switch on the same board all as directed by Engr-in-charge |
| 13 | All as per item No 4 here in before but for power point wiring using with 2.5 sqmm PVC FRLSH insulated ,unsheathed, copper conductor stranded 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green . |
| 14 | M&L for concealed point wiring with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit of size not less than 20mm ISI marked ivory white With all accessories, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . |
| 15 | For one light point or fan point controlled by one switch all as directed by Engr-in-charge |
| 16 | For one Call Bell point controlled by one push button switch all as directed by Engr-in-charge |
| 17 | For 5Amp independent socket point controlled by one switch all as directed by Engr-in-charge |
| 18 | For one 3 pin ,5 Amp socket point with other switch on the same board all as directed by Engr-in-charge |
| 19 | For one light, point controlled by two way switch |
| 20 | All as per item No 6 here in before but for power point wiring using with 2.5 sqmm PVC FRLSH insulated ,unsheathed, copper conductor stranded 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green . |
| 21 | S&F Modular switch, one way,6 Amp 230, 1 module . |
| 22 | S&F Modular switch, two way, 6 Amp 230, 1 module. |
| 23 | S&F modular socket 6 Amp-2/3 pin combined 2 module . |
| 24 | S&F Modular switch, one way,6 A/16 Amp 230, 1 module . |
| 25 | S&F modular socket 6 A/16-2/3 pin combined 2 module . |
| 26 | S&F Modular fan step regulator 120 Watt -2 module . |
| 27 | S&F Modular bell push 6A one module . |
| 28 | S&F switch piano type flush, single pole, one way 5 A 230 V. |
| 29 | S&F socket outlet, 5 pin, 5 Amp, flush type, 230 V. |
| 30 | S&F switch piano type flush, single pole, one way 15 A 230 V . |
| 31 | S&F socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V. |
| 32 | S&F ceiling rose, surface backlite,three terminal . |
| 33 | S&F lamp holder insulated with back plate suitable for Angle/Batten fitting. |
| 34 | S & F in repair/replacement bell ding dong 230 V, single phase. |
| 35 | S&F bell push flush type one way 5Amp 240 Volt. |
| 36 | M&L concealed sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC conduit not less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge |
| 37 | M&L surface conduit sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl pvc conduit of suitable size . ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge |
| 38 | M&L sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 10 sqmm (for main current and earth ) drawn in & inc pvc conduit of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 10 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge |
| 39 | M&L sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge. |
| 40 | M&L sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 2.5 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 2.5 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge . |
| 41 | S&F testing and commissioning of MCB SP 240 volt 6 Amp to 32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down . |
| 42 | S&F testing and commissioning of MCB SPN 240 volt 32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down. |
| 43 | S&F testing and commissioning of MCB SPN 240 volt 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down. |
| 44 | S&F testing and commissioning of MCB SPN 240 volt 63 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down. |
| 45 | S&F in replacement of TP 40 Amps 240 V including making electrical coming/outgoing connections with lugs/thimbles, including taking down.all as specified & directed. |
| 46 | S&F in replacement of TP 63 Amps 240 V including making electrical coming/outgoing connections with lugs/thimbles, including taking down.all as specified & directed. |
| 47 | S&F in replacement of TP 100 Amps 240 V including making electrical coming/outgoing connections with lugs/thimbles, including taking down.all as specified & directed. |
| 48 | S&F in replacement of TPN 40 Amps 415 V including making electrical coming/outgoing connections with lugs/thimbles, including taking down.all as specified & directed. |
| 49 | S&F in replacement of TPN 63 Amps 415 V including making electrical coming/outgoing connections with lugs/thimbles, including taking down.all as specified & directed. |
| 50 | S&F metallic sheet metal enclosure for DB Single door(IP-42/43) When MCBs to be used SPN 2 ways, 240 V with 200Amps rated bus bar including taking down.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate . |
| 51 | S&F double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar including taking down.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate . |
| 52 | S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar including taking down.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate . |
| 53 | S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 12 way, 240 V with 200 Amps rated bus bar including taking down.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate . |
| 54 | S&F double door metallic sheet metal enclosure for MCB DB double door TPN 4 Way 415 Volts with 200 Amps rated bus bars including taking down. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate . |
| 55 | S & F of surface mounting LED flat panel 2'X2' made of sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffiuser, IP20 of capacity 36 watt ,input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 ,complete all as specified and directed. Note Warrenty on light should be of minimum 02 Years. |
| 56 | S & F of recess mounting LED flat panel 2'X2' made of sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffiuser, IP20 of capacity 36 watt ,input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 ,complete all as specified and directed. Note Warrenty on light should be of minimum 02 Years. |
| 57 | S & F LED light fitting 1x15 W bulkhead luminaires Pressure die cast aluminium housing crystal white lumens 100lm/watt IP-65 including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in charge.Note Warrenty on light should be of minimum 02 Years. |
| 58 | Supply and fixing LED batten lights fitting made of Aluminium extrusion 1x 20W (4 feet) NW/WW , input voltage 140-270 V AC,CCT 6500K/2700K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 , connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr -in -charge. Including Taking down old Tublight fittingsNote :-Warrenty on light should be of minimum 02 Years. |
| 59 | Supply and fixing LED batten light fitting made of Aluminium extrusion mirror type with high out put diffuser 1x10 watt (2 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 with driver including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed by Engr in charge.Including Taking down old Tubelight fittingsNote:- Warrenty on light should be of minimum 02 Years. |
| 60 | Supply & fix of exhaust fan steel body AC single Phase. 230V of size 230mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 61 | Supply & fix of exhaust fan steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 62 | Supply & fix of exhaust fan plastic complete AC single Phase. 230V of size 150mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 63 | Supply & fix of exhaust fan plastic complete AC single Phase. 230V of size 200 mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 64 | Supply & fix of exhaust fan plastic complete AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 65 | Supply & fix of ceiling fan complete with blades, down rod from existing roof / trus to fall ceiling, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 66 | Taking down old existing fitting any type and S & F of LED Recess mounted Down Light Round type with independent electronic LED driver ,made from cast aluminium housing and opaue polymer diffuser for optimum light output as per site requirement round light fitting of capacity 18 Watt, input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 suitable for mounting with Armstrong/Grid ceiling withcomplete flexibility,complete all as specified and directed.Note :- Warrenty on light should be of minimum 02 Years. |
| 67 | Taking down old existing fitting any type and S & F of LED Recess mounted Down Light Square type with independent electronic LED driver ,made from cast aluminium housing and opaue polymer diffuser for optimum light output as per site requirement Square light fitting of capacity 18 Watt, input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 suitable for mounting with Armstrong/Grid ceiling withcomplete flexibility,complete all as specified and directed.Note :- Warrenty on light should be of minimum 02 Years. |
| 68 | S&F \\"Modular AC Box With 20A SP MCB,Metal Enclosure & Unbreakable Heavy Duty With ISIPlug Top\\" flush mounting enclosure complete all as directed by Engineer-in-Charge |
| 69 | Supply & fix for replacement of metal clad box with plug and socket 20 Amps with one MCB SPN of 20 Amps complete all as specified and directed |
| 70 | S&F double door metallic sheet metal enclosure for DB double door(DPX-125 ) VTPN 4 Way 415 Volts with 125 Amps rated bus bars IP 43- \\"IK 09 including taking down.. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will b including in item rate . |
| 71 | S&F MCCB 63 Amps 4 pole, 415 V 16 KA including taking down.. |
| 72 | S&F MCCB 100 Amps 4 pole, 415 V 16 KA including taking down.. |
| 73 | M&L for provn of Earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |
| 74 | Supply and fix in repairs modular PVC board complete of following sizes all as specified and directed by engir -in -charge. |
| 75 | 3 Module |
| 76 | 4 Module |
| 77 | Taking out old US laminated sheet and S & F new laminated super hylem sheet white colour 3mm thick of sizes including fixing of switches, sockets as per existing pattern. (a) Laminated hylum sheet of size 8\\" x 5\\" |
| 78 | All as per Item Ser No 62.00 above but of size 5\\"x5\\" |
| 79 | All as per Item Ser No 62.00 above but of size 8\\"x10\\". |
| 80 | All as per Item Ser No 62.00 above but of size 8\\"x12\\". |
| 81 | All as per Item Ser No62.00 above but of size 9\\"x11\\". Please Enable Macros to View BoQ information |
| 82 | All as per Item Ser No62.00 above but of size 9\\"x11\\". Please Enable Macros to View BoQ information |