| 1 | Taking down carefully copper/ aluminum point wiring of any size and description (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc , removing material for taking credit and making good disturbed surface of walls, floors, etc. |
| 2 | Material and labour for point wiring for one light point or one fan point or one bell point controlled by one switch in replacment of unsv modular fitting complete with 1.5 sq mm single core multi stranded copper conductor PVC FRLSH insulated unsheathed 1100 Volt grade cable in and incl concealed PVC conduit (ISI Marked) with accessories including Modular sunken box with modular plate and cover with 1.50 sq mm insulated unsheathed PVC FRLSH multistranded copper conductor for common earth and connecting to earth dolly and making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling colour all as specified and directed by Engr in charge. Note: Colour coding Must be followed as per IEC rules Phase-Red wire, Neutral-Black wire and earth-Green wire. |
| 3 | All as per Serial item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on same board. |
| 4 | All as per Serial item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board. |
| 5 | All as per Serial item No. 2 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps |
| 6 | Supply & Fixing Modular switch 1 way 6A 1 module |
| 7 | Supply & Fixing Modular switch 1 way 16A 1 module |
| 8 | Supply & Fixing Modular Socket, 6A - 2/3 pin combined 2 module |
| 9 | Supply & Fixing Socket 6A/16A - 2/3 pin combined 2 module |
| 10 | Supply & Fixing Fan step regulator, 120W - 2 module |
| 11 | Supply & Fixing Bell Multi Music type |
| 12 | S & F in replacement only switch piano type 230 volts, 6 Amps, single pole |
| 13 | S & F in replacement only switch piano type 230 volts, 15 Amps, single pole |
| 14 | S & F in replacement only Socket out let 2 in 1, 3 pin, 5 Amps flush type 230 volts |
| 15 | S & F in replacement only switch Socket out let combination 2 in 1, 3 pin, 5 Amps flush type 230 volts |
| 16 | S & F in replacement only Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type |
| 17 | S & F in replacement only fan regulator step type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 60/100Watt complete all as specified & directed. |
| 18 | M&L for point wiring for one light or one fan or one bell point controlled by one switch with using 1.5 Sqmm single core FRLSH PVC insulated unsheathed multi stranded copper conductor cable 1100V grade drawn through with incl PVC casing in capping /conduit (size of as required at site but not less than 20mm) with accessories like bends tees, junction boxes and terminal boxes for mounting fittings etc. fixed on recessed in wall or ceiling etc including 1.5 Sqmm single core FRLSH PVC insulated but unsheathed multistrandard copper conductor cable 1100V grade as earth continuity wire connected to common earth dolly with incl PVC board size as required at site complete all as specified and directed. . Note: Colour coding Must be followed as per IEC rules Phase-Red wire, Neutral-Black wire and earth-Green wire. |
| 19 | All as per Serial item No. 18 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on same board. |
| 20 | All as per Serial item No. 18 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board. |
| 21 | All as per Serial item No. 18 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps |
| 22 | Supply and fixing for switch piano flush type, 5 amps, single pole, one way, 230 volts AC |
| 23 | Supply and fixing for Bell push flush type, 5 Amps, single pole, 230 volts AC |
| 24 | S & F for call bell AC, 230 volts, single pole |
| 25 | S & F for socket outlet, five pin, 5 amps, flush type, 230 volts AC |
| 26 | S & F for switch socket outlet combination, five pin, 5 amps, flush type, 230 volts AC |
| 27 | S & F for switch socket outlet combination, multipurpose, 3 pin, 15 amps and 3 pin 5 amps controlled by one switch, flush type, 230 volts AC |
| 28 | S & F for ceiling rose surface bakelite, three terminals |
| 29 | S & F fan regulator step type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 60/100Watt complete all as specified & directed |
| 30 | Supply and fixing in replacement of Lamp Holder, PVC FRLS/polycarbonate type with back plate suitable for batten fittings. |
| 31 | Taking down old submain wiring and S&F in replacement of sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4 Sq.mm of 1100 Volts voltage rating drawn through and including PVC casing caping of size not less than 25mm with standard accessories, along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sq.mm as earth continuity conductor complete all as specified and directed.Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit. |
| 32 | All as per Serial item No. 31 here-in-before but sub main wiring with using two single core 6.0 sqmm FRLS PVC insulated stranded copper conductor cable Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit |
| 33 | All as per Serial item No. 31 here-in-before but sub main wiring with using two single core 10.0 sqmm FRLS PVC insulated stranded copper conductor cable Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit |
| 34 | Supply & Fixing in replacement industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 volts with including 20 Amp SP MCB complete all as specified and directed. |
| 35 | Supplying and fixing 63 Amp, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 63 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 36 | Supplying and fixing 32 Amp, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 32 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 37 | Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 12 way with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified & as directed by Engr-in-charge. Make : Havells /LEGRAND /L&T/ C&S/ SCHIENDER/ABB/ANCHOR. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 38 | All as per item No 37 above but 16 way |
| 39 | All as per item No 37 above but 8 way |
| 40 | All as per item No 37 above but 4 way |
| 41 | Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 4 way TPN 415 V with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified & as directed by Engr-in-charge. Make : Havells /LEGRAND /L&T/ C&S/ SCHIENDER/ABB/ANCHOR.Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 42 | S & F for MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA with including IP 65 sheet metal encloser complete all as specified and directed. |
| 43 | S & F in replacement MCB Triple pole & neutral (TPN), 25 to 63 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified & as directed by Engr-in-charge. Make : Havells /LEGRAND /L&T/ C&S/ SCHIENDER/ABB/ANCHOR |
| 44 | S & F in replacement MCB single pole & neutral (SP&N), 32 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified & as directed by Engr-in-charge. Make : Havells /LEGRAND /L&T/ C&S/ SCHIENDER/ABB/ANCHOR |
| 45 | S & F in replacement MCB single pole (SP) 6 to 32 Amps, 240 volts, 10KA, ‘B’ series, with proper size lugs and connections complete all as specified & as directed by Engr-in-charge. Make : Havells /LEGRAND /L&T/ C&S/ SCHIENDER/ABB/ANCHOR |
| 46 | S & F in replacement Surface and wall mounted high efficiency 1x20 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver CRI >80, Beam Angle120° complete with all accessories internally pre wired and including connection up with twin core flexible copper conductior cable all as specified and directed. |
| 47 | S & F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10/12 watt 220 V AC Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square shape, CRI >80, Beam Angle 120° including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 48 | S & F in replacement round or Square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells/Bajaj/Philips) |
| 49 | S & F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. (Make: Havells/Bajaj/Philips) |
| 50 | S & F in replacement LED light fitting 1x9W/1X10W bulkhead luminaires including LED light holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. (Make: Havells/Bajaj/Philips) |
| 51 | S& F in replacement decorative flood light , suitable for focasing of tree / buildings of capacity 100 watt, , 240 volt, 50 HZ and as directed by Engr -In-Charge |
| 52 | Supply & fixing in replacement LED bulb retrofit type 9 watt, efficiency 100 Lm/W suitable for 180 volt to 280 volt. E22 & E27 type |
| 53 | Supply & fixing in replacement LED bulb retrofit type12 watt, efficiency 100 Lm/W suitable for 180 volt to 280 volt, |
| 54 | Supply & fixing in replacement LED bulb retrofit type15 watt, efficiency 100 Lm/W suitable for 180 volt to 280 volt. |
| 55 | Supply & fixing in replacement LED bulb retrofit type 5 watt, Red/ Green colour suitable for 180 volt to 280 volt. |
| 56 | Supply & fixing in replacement 36/42 watt LED driver suitable for 180 to 275 volt LED light fitting ( Make:- Bajaj/Havells/ Orient/Polycab) |
| 57 | Supply & fixing in replacement of Decorative post top lantern doom made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base as per existing sample complete all as directed |
| 58 | S & F in replacement of for Rigid non-metallic PVC conduit/ PVC casing caping of size 20 mm inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |
| 59 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover and including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed. Please Enable Macros to View BoQ information |
| 60 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover and including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed. Please Enable Macros to View BoQ information |