| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 2 | Supply and fix Framed work such as grills, gratings,gates etc.using any rolled sections or tubular sections with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, and similar work conforming to Fe.290.Gde-E-165. all as specified and as directed |
| 3 | Supply and fix F Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ® and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed |
| 4 | Material and Labour Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290(Gde E 165) all as specified and as directed |
| 5 | Supply and fix Mild steel screw bolt (machine made) 5 to 10 mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long n exc 10 cm long all as specified and as directed |
| 6 | Supply and fix in repairs of 3mm dia PVC coated chainlink wire mesh of size 50x50mm with 2mm galvanised corewire (overall dia 3mm including PVC coating) fixed to fencing posts with flats using bolts and nuts complete all as specified (nuts and bolts shall be measured seperately complete all as specified and as directed. |
| 7 | Supply and fix in repairs of welded steel wire mesh having weight n.exc 4 Kgs/Sqm fixed on to MS frame with welded joints complete all as specified and as directed. |
| 8 | Material and Labour for preparation of new steel surface and applying two coats of Apcolite Rust Shield PU enamal paint over two coats of True care yellow metal primer of Asian paints or equivalant in Berger, Nerolac paint Ltd as approved as per manufacturers instructions complete all as specified and as directed. |
| 9 | Material and Labour for preparation of old steel surface and applying one coat of Apcolite Rust Shield PU enamal paint or equivalant in Berger, Nerolac paint Ltd as approved as per manufacturers instructions complete all as specified and as directed. |
| 10 | Demolition of cement concrete un reinforced of any description and in any position not otherwise specifically provided for and removing to dumping areas earmarked inside INA complete all as specified and as directed. |
| 11 | Material and Labour plain cement concrete 1:3:6 Type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete as specified and as directed. |
| 12 | Material and Labour plain cement concrete 1:4:8 Type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete as specified and as directed. |
| 13 | Providing and laying pre cast cement concrete in apex stones, Kerb stones and the like including chamfers, weatherings, throating in mortar complete with joints to match in cemant concrtete Type C0 1:3:6 using 12.5mm graded aggregate set in CM 1:4 complete all as specified and as directed. |
| 14 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water,etc.complete all as specified and as directed. |
| 15 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing to dumping areas earmarked inside INA complete all as specified and directed. |
| 16 | Material and Labour for Pre-cast cement concrete block masonry 1:3:6 Type C1 (using 20 mm aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6) all as specified and as directed. |
| 17 | Material and Labour for Walling of laterite stone built in and setting in cement mortar 1:6, complete all as specified and as directed. |
| 18 | Material and Labour walling of Random rubble ,Uncoursed ,well bonded laid in CM 1:6 in retaining walls all as specified and as directed |
| 19 | Labour only for laying in CM 1:6 of reusable RR masonry obtained from demolition all as specified and as directed |
| 20 | Material and Labour for flush pointing to random or polygonal rubble ,uncoursed or bought up to course in CM 1:4 all as specified and as directed. |
| 21 | Material and Labour for Rendering 15mm thick in CM 1:4 on any faces of brick work or concrete surfaces finished even & smooth without using extra cement all as specified and as directed. |
| 22 | Material and Labour rendering 15mm thick on stone masonry surfaces in CM 1:4 surface finished even and smooth without using extra cement complete al as specified and as directed. |
| 23 | Material and Labour for PCC Type B-0 (1:2:4) using 12.5 mm graded stone aggregate as in copings complete all as specified and as directed Note:Unit rate quoted shall be deemed to be inclusive of use and waste of formwork |
| 24 | Material & Labour for Finishing walls with Premium Acrylic Smooth exterior emulsion paint with Silicone additives of required shade on new work (Two or more coats applied as per manufacturers instructions) over and including priming coat of exterior primer applied as per manufacturers instructions including preparation new surfaces complete all as specified and as directed. |
| 25 | Material & Labour for Finishing walls with one coat of Premium Acrylic Smooth exterior emulsion paint with Silicone additives applied as per manufacturers instructions (including applying additional coats wherever required to achieve even shade and colour) of required shade on old work including preparation of surfaces complete all as specified and as directed. |
| 26 | Cleaning of closed storm water drains having width not exc 1 m and any depth up to 1.5 m removing soil. debris, deposits etc from the drain and disposing up to distance of 500 mtr including removing and refixing of necessary drainage covers for facilitating cleaning complete all as specified and as directed. |
| 27 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition and removing to dumping areas earmarked inside INA complete all as specified and as directed. |
| 28 | Material and Labour for reinforced Pre-cast cement concrete 1:2:4 Type B-1 using 20 mm graded stone aggregate as in cover slabs for man holes, drains, water throughs etc with plain fair faces including use of necessary form work and setting in cement mortar 1:4 complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately. |
| 29 | Material and Labour Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 30 | Demolition of cement concrete un reinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing to dumping areas earmarked inside INA complete all as specified and as directed. |
| 31 | Material and Labour for 100 mm thick plain Cement concrete 1:4:8 Type D- 2 using 40 mm graded stone aggregate as in sub base, sub floors etc complete all as specified and as directed. |
| 32 | Material and Labour for 75 mm thick plain Cement concrete 1:4:8 Type D- 2 using 40 mm graded stone aggregate as in sub base, sub floors etc complete all as specified and as directed. |
| 33 | Material and Labour for 100 mm thick plain Cement concrete 1:2:4 Type B- 1,using 20mm graded stone aggregate as in hard standing, floors/ pavings etc surface finished even and fair without using extra cement complete all as specified and as directed. |
| 34 | Material and Labour for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and as directed. |
| 35 | Demolition of Stone slabs, Granite,Interlock tiles and Chequered tiles of any description or thickness in floors aprons etc.laid bedded and pointed in any mortar complete all as specified and as directed. |
| 36 | Material and Labour sand filling (50 mm average thickness) under floors in foundations and for laying Interlocking paver blocks including watering and consolidation complete all as specified and as directed . |
| 37 | Material and Labour machine pressed precast concrete interlocking paver block any shape and size polished with grey cement and pigment confirming to IS 15658-2006 of 60mm thickiness M-35 grade complete all as specified and as directed. |
| 38 | Material and Labour PCC 1:2:4, 25 mm thick Type B0 using 12.5mm graded stone aggregate as in floor finished even and fair with out using extra cement complete all as directed. |
| 39 | Material and Labour for Chequred cement concrete tiles 30cm X 30cm X 20mm thick, set ,pointed & jointed in neat cement slurry in floors polished with whitecement & no pigments laid over and including 20mm thick cement screed base (1:6) and all as directed. Please Enable Macros to View BoQ information |