| 1 | DM-FL-TI-CM) Dismantling the existing damaged Floor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs without affecting the adjacent structures and clearing the debris away from the site and etc., all complete and as directed by the departmental officers. |
| 2 | DW-DMB-PCC) Dismantling the damaged Plain cement concrete flooring without affecting the adjacent structures, including the cost of required tools and plants and clearing the debris away from the site etc., all complete and as directed by the departmental officers. |
| 3 | DW-DMB-RCC -MM) Dismantling RCC by manual / by using deploying machineries including all tools and plants required etc. all complete as per relevant standard specifications and as directed by the departmental officers. |
| 4 | Clean removal of cement plaster from walls without damaging the existing structure and surroundings and clearing the debris away from the site including cost of required tools and plant and necessary scaffolding if necessary etc., all complete |
| 5 | DW-D-W-F) Removing the damaged Doors and Windows including removal of frames, hinges and fastenings including all accessories without affecting the adjacent structures including the hire charges for tools and plants and scaffolding if any and clearing the dismantled materials away from the site etc., all complete and as directed by the departmental officers. |
| 6 | DM-PT-WE-IN) Dismantling the damaged Pressed tiles laid over cement mortar and Weathering Course lime concrete without affecting the adjacent structures in all floors including the cost of required tools and plants and clearing the debris away from the site etc., all complete and as directed by the departmental officers. |
| 7 | CN-FB-PCC-1:5:10) Plain cement concrete 1:5:10 (One of cement, five of crushed stone sand and ten of hard broken stone Jelly including Mortar Plasticizer (Liquid) at 200ml per bag) for foundation and basement using 40mm gauge hard broken stone jelly inclusive of shoring, strutting and bailing out water wherever necessary ramming, curing etc., complete in all respects complying with relevant standard specifications and as directed by the departmental officers. |
| 8 | BW-FB-KB-CM 1:5) Brick work in Cement Mortar 1:5 (One of cement and five of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) using Kiln burnt country bricks of size 8¾”x4¼”x2¾” (22x11x7cm) in foundation and basement including dewatering wherever necessary proper setting, curing etc., complete with relevant standard specifications. |
| 9 | BW-PW 114mm-KB-CM 1:4) Brick partition wall in Cement Mortar 1:4 (One of cement and four of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 110mm thick for super structure in the following floors using Kiln burnt country bricks of size 8¾”x4¼x2¾” (22x11x7cm) including labour for fixing the doors, windows and ventilator frames in position, fixing of hold fasts, scaffoldings, curing etc., complete in all respect complying with relevant standard specifications.BW-PW 114mm -SS-KB-CM 1:4-(GF))b. In Stilt / Ground Floor |
| 10 | Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating - Providing and Applying Polyurethane hybrid liquid applied GRIHA certified Waterproofing coating with flutyne protection technology, single component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof having Tile or any non-porous surface applied @ 1.5 l/m2 in 2 coats to achieve 1mm DFT, having tensile strength with 45 gsm glass fibre mesh 4N/mm2 confirming to ASTM D 412; Elongation at break ≥ 300% and Crack bridging ability up to 3mm, SRI Index 106 as per ASTM E 1980- 01, Water permeability @5 bar – Nil as per EN12390 - 8:2019, including surface preparation, priming the surface with single component high-performance waterborne tile primer which is suitable for non - porous surface at a rate of 0.14 L/m2 and spreading 45 gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification. |
| 11 | Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. |
| 12 | CN-TEC-WC-NS) Weathering Course with concrete broken brick jelly 20mm gauge in pure burnt lime stone slaked and screened (No Sand) over RCC Roof Slab with proportion of brick jelly to lime (fat lime) being 32: 12 1/2 by volume well beaten with wooden beaters for giving the required slope and thickness complying with relevant standard specification and as directed by the departmental officers. |
| 13 | Pointing the pressed tiles with CM 1:3 (one of cement and three of crushed stone sand) including cost of all materials and labour charges for pointing, curing etc., all complete and as directed by the departmental officers. |
| 14 | TL-RO-PT-CM 1:3) Finishing top of roof with one course of Pressed Tiles of approved superior quality of size 23cmx 23cmx20mm thick laid over weathering course in CM 1:3 (One of cement and three of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag,) 12mm thick mixed with Water proofing compound at 2% by weight of cement used and pointed neatly with the same cement mortar mixed with water proofing compound including curing etc., as per standard specifications. (The quality of tiles shall be got approved from the Executive Engineer before use) |
| 15 | FW-FW-WOS-RCC) Providing Form work and centering for reinforced cement concrete works including supports and strutting up to 3.30m height for plane surfaces as detailed below with all cross bracings using mild steel sheets of size 90cm x 60cm and MS 10 gauge stiffened with welded mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak or country wood joists of size 10cmx6.5cm spaced at about 90cm centre to centre and supported by casurina props 10cm to 13cm dia spaced at 75cm intervals and removing the same after a specified period without damaging the R.C.C works etc., complete complying with standard specifaction and as directed by the departmental officers. FW-SS-WS-PS)b.Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase waist, portico slab and other similar works |
| 16 | FW-SS-WS-CO) c.For Square and rectangular columns and small quantities such as sunshade, parapet cum drops window boxiing, fin projection and other similar works. |
| 17 | CN-F&S-RCC-M20) Providing and laying in position, Standardised Concrete Mix M-20 Grade in a accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for the all RCC items of worksCN-SS-RCC-M20 - (GF)b. In Stilt /Ground Floor |
| 18 | CN-SS-RCC-M20-(1F)) c. In First Floor |
| 19 | CN-SS-RCC-M20-(2F)) d. In Second floor |
| 20 | CN-SS-JV-M20-50) Precast cement concrete Jally ventilator using standardised concrete mix M20 (without vibrating charges) using 20mm gauge hard broken stone jelly for the following thickness excluding the cost and fabrication of reinforcement grills but including precasting, moulding, curing, finishing and fixing in position complying with relevant standard specifications etc., complete in the following floors. 50mm thickCN-SS-JV-M20-50-(GF))a. In Ground Floor |
| 21 | TL-FL-Cudda-40mm thick) Providing Cuddappah slab of 40mm thick, finishing with two sides for cupboard, ward-robes, shelves , kitchen platform slabs, sink and other similar works including finishing and fixing in position complying with relevant Standard specifications etc., complete in the following floors (Measurement will be taken including bearing also) as directed by the departmental officers (Quality of Cuddappah slab shall be got approved by the Executive Engineer before fixing.a) In Ground Floor |
| 22 | RE-RTS-Fe-NC) Supplying, fabricating and placing in position of Mild steel Grills / Ribbed Tor Steels (without cement slurry) of all diameters for reinforcement for all floors including cost of binding wire, bending tying etc., all complete and as directed by the departmental officers. |
| 23 | PL-CL-CM 1:3-10mm thick) Special ceiling plastering in cement mortar 1:3 (One of cement and three of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 10mm thick for bottom of roof, stair, waist, landing and sunshades in all floors finished with neat cement |
| 24 | PL-OU-CM 1:5-12mm) Plastering with CM 1:5 (One of cement and five of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 12mm thick finished with neat cement |
| 25 | CN-FL-Ellis-Chip) Finishing the top of flooring with cement concrete 1:3 (One of cement and three of blue granite chips of size 10mm and below) 20 mm thick Ellispattern Flooring (No Sand) |
| 26 | PL-WPC-CM 1:3-20mm) Plastering in cm 1:3 (one of cement and three of crushed stone sand (One of cement and three of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 20mm tk. mixed with water proof compound at 2% by weight of cement for sump including scaffolding curing, finishing etc., complete in all respects and complying with standard specifications. |
| 27 | JN-UPVC D-SL-L) Providing and fixing factory made unplasticized polyvinyl chloride (UPVC) Door Frame of size 50X47mm with a wall thickness of 5mm |
| 28 | Supplying and fixing of PVC Sliding Door with Roller etc., all complete and as directed by the departmental officers. |
| 29 | WS-EX-ASTM-PVC) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of suitable schedule (40/60/80) of wall thickness not less than the specified in IS 4985 suitable for plumbing by threading of wall thickness including the cost of suitable PVC/UPVC/GI specials /GM specials WS-EX-ASTM-32 PVC) a) 32mm dia |
| 30 | WS-EX-ASTM-25 PVC)b) 25mm dia |
| 31 | WS-EX-ASTM-20 PVC)c) 20mm dia |
| 32 | SA-Ex-SWR P-50) Supplying,laying and concealing the 50mm dia PVC (SWR) pipe with ISI mark conforming to IS 13952:1992- type `B` for waste water line with relevant specials conforming to IS 14735 including jointing and making good of the dismantled portion with necessary connections to sanitary fittings etc., complete in all respects and as directed by the departmental officers |
| 33 | SA-Ex-SWR P-Dia) Supplying and fixing the following dia PVC (SWR) pipe with ISI mark confirming to IS 13952:1992- type `B` for soil line with relevant specials confirming to IS 14735 SA-Ex-SWR P-110a) 110mm dia PVC SWR pipe including all required PVC specials etc., all complete., |
| 34 | SA-Ex-SWR P-75b) 75mm dia PVC SWR pipe including all required PVC specials etc., all complete., |
| 35 | WS-EX-RWD-PVC) Supplying and fixing of following dia PVC SWR pipe with ISI mark conforming to IS 13952:1992- type `A` for Rain water down fall pipe with relevant specials WS-EX-RWD-110)b. 110mm dia PVC SWR pipe |
| 36 | SA-IN-IWC-OGF) Supplying and fixing of Indian Water Closet white glazed (oriya type) of size 580 mm x 440 mm of approved make with ISI mark (to be got approved from EE before use) with PVC SWR grade 'P' or 'S' trap(Other than ground floor) |
| 37 | Supplying and fixing of 250mm length Tower Bolt etc., all complete and as directed by the departmental officers. |
| 38 | Supplying and fixing of 250 x 16mm Aldrop etc., all complete and as directed by the departmental officers. |
| 39 | SA-IN-FT-10 lt) Supply and fixing of 10 litre capacity Handle type PVC low level flushing tank (cistern - wall mounting type) of superior variety (white) with all fittings inclusive of cost of all materials, labour charges for fixing in position in appropriate level (suitable for IWC) as directed by the departmental officers and as per relevant standard specifications (The colour quality and brand should be got approved from the Executive Engineer before use) |
| 40 | SA-IN-NT-CI) Supplying and fixing of 100mm x 75mm Cast Iron Nahini / Floor Trap with Stainless Steel Grating etc., all complete and as directed by the departmental officers. |
| 41 | SA-IN-NT-PVC) Supplying and fixing of PVC Nahani Trap not less than 75mm 4 way / 2 way (Superior variety) |
| 42 | SA-Ex-IC-1:8:16) Construction of Inspection chamber with brickjelly cement concrete 1:8:16 ( One of cement, eight of crushed stone sand and sixteen of broken brick jelly 40mm gauge 15cm, thick for foundation and 23cm thick brick mansonry in CM 1:5 using chamber burnt bricks of size 9'x4 1/2'x3' and plastering with CM 1:3 (one of cement, three of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 50mm thick Precast cover slab excluding the cost and fabrication of reinforcement grills but including benching channelling fixing the cover slab in position curing, finishing etc., complete in all respects.SA-Ex-IC-60cm x 60cm x 60cma) 60cm x 60cm x 60cm |
| 43 | EL-IN-OEP-FP) Wirng with 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable with surface run by means of 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable confirming to IS 694 / 1980 with ISI mark in PVC rigid conduit pipe heavy duty with ISI mark with suitable size MS box of 16g thick concealed and covered with 3mm thick laminated hylem sheet for FAN POINT controlled by 5 amps flush type switch including citcuit mains, cost of all materials, specials, etc., all complete, (Open wiring) |
| 44 | EL-IN-EF-FH) Supply and fixing of best approved superior variety concealed type Fibre box with M.S. Fan Hook of 100mm dia, 75mm depth and 3mm thick including cost and fixing in position etc., complete and as directed by the depatmental officers. (The quality should be got approved by the Executive Engineer before use). |
| 45 | EL-IN-EF-AC) Charges for assembling and fixing of ceiling fan of different sweep with necessary connections and fixing of fan regulator on the existing board etc., all complete (Excluding cost of fan) |
| 46 | EL-IN-EF-F) Supply and delivery of following Electric Ceiling fan with ISI mark with blades and double ball bearing, capacitor,etc., complete with 300mm down rod, canopies, capacitor, shackleblades with dimmer electronic regulator suitable for operation on 230 volts 50 HTZ single phase AC supply conforming to ISS No.374/2019 and provided with insulation .a) 48\\" Electric fan 1200mm sweep |
| 47 | EL-IN-OEP-CP) Wirng with 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable with surface run by means of 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable confirming to IS 694 / 1980 with ISI mark in PVC rigid conduit pipe heavy duty with ISI mark with suitable size MS box of 16g thick concealed and covered with 3mm thick laminated hylem sheet for 5 amps. 5 pin plug socket point at convenient places including circuit mains, cost of all materials, specials, etc., all complete, (Open wiring) |
| 48 | EL-IN-LED.F-TL) Supply and fixing of 4' long 18 W Crystal Glass LED tube Light with ISI mark including cost of all materials twin core flex wire, TW round block and labour charges for fixing in position. |
| 49 | EL-IN-EF-9W) Supplying and fixing of following watts LED bulb including ncessary connections, cost of materials .a) 9 watts LED bulb |
| 50 | TL-WL-GZT-CM 1:2) Supplying and fixing of Colour glazed tiles (Best approved quality and the same shall be got approved from the Executive Engineer before using) over cement plastering in CM 1:2 (One of cement and two of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 10mm thick |
| 51 | TL-FL-CT-CM 1:3) Supplying and fixing of colour Ceramic Tiles Anti skid without corrugated design for flooring and other similar works (Best approved quality, colour and shade shall be got approved from the Executive Engineer before using) over cement mortor 1:3 (One of cement and three of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 20mm thick |
| 52 | TL-FL-CDT-CM 1:3) Supply and laying superior variety Concrete Designer tiles for flooring in CM 1:3 (One of Cement and three of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 20mm thick |
| 53 | TL-FL-GS-CM 1:3-(GF)) Supplying and laying of following colour Granite slabs (superfine polished with machine cut edges) of size 4'-0'x 2'-0' of 18 to 20 mm thick for flooring (Best approved quality and the same shall be got approved from the Executive Engineer before using) over cement plastering in CM 1:3 (One of cement and three of crushed stone sand) 20mm thick including Cost of Mortar Plasticizer (Liquid) at 200ml per bag fixing in position, cutting the tiles to the required size wherever necessary, pointing the joints with Grout (Tile joint filler), curing, finishing etc., all complete and as directed by the departmental officers. (The brand and quality of tiles should be got approved from Executive Engineer before use ).TL-FL-JGS-CM 1:3a. Jet Black |
| 54 | SA-IN-Spl.-Fit) Supplying and fixing of best approved quality of following CP water supply/Sanitary fittings confirming to ISI specification including cost and labour charges for fixing etc., complete complying with relevant standard specifications and as directed by the departmental officers (The brand and quality of the materials should be got approved from the Executive Engineer before use)SA-IN-CP-SH)b) CP Shower arm overhead shower rose |
| 55 | IN-FT-RR-M) Supplying and fixing of following rooms fittings including cost of materials with screws, TW plugs and labour charges for fixing in position etc. complete in all respects and as directed by the departmental officers.IN-FT-Alu TR-75cm)a) 75cm long Aluminium Towel Rail |
| 56 | IN-FT-ST-BR)c) Brass Chromium plated Soap Tray of size 150mm x 100mm |
| 57 | JN-V-UPVC-LV) UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. |
| 58 | MW-MS-GR) Supplying and fixing Mild Steel grills as per the design approved to verandah enclosure or gate including one coat of primer and labour for fixing in position etc. all complete. |
| 59 | Supply and fixing of Galvanium Roof sheet of 0.47mm thick including cost of all materials, cutting, welding & labour charges, fixing in position necessary screws, nuts, scaffolding etc., all complete, as directed by the departmental officers. |
| 60 | Providing and filling the tile joint with epoxy grout with following specification: Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the departmental officers. The rate inclusive of cost of materials and labour, etc., complete. |
| 61 | Treating mild Dampness in Interior Walls - Providing and Applying Acrylic Co Polymer single component specially designed waterproof protective coating that prevents damp patches on walls without any dilution at rate of 0.25kg/m2 in 2 coats to achieve total dry film thickness of 170 microns DFT. The material having followed technical properties: crack bridging ability up to 1mm as per EN 1062, Tensile strength ≥ 2N/mm² as per ASTM D 412, adhesion strength 1.5N/ mm² as per ASTM D4541. The finished cost including surface preparation completely as per specification. |
| 62 | Treating Severe Dampness & Rising dampness in Walls - Providing and Applying two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface or walls applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation & treatment of cracks completely as per specification. |
| 63 | UGT/OHT (inside) waterproofing with Antimicrobial Coating Waterproofing: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the UGT/ OHT tank applied @ 2.2kg/m² in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/mm² as per ASTM D 412, Adhesion strength: 0.80N/mm² as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. |
| 64 | Exterior Wall Waterproof cum Decorative Coating Providing and Applying high build exterior waterproof coating for external wall, parapet & Chajja, which is single component, cold applied, Reactive Acrylate copolymer technology. Apply one base coat of universal elastomeric exterior waterproof coating @0.25L/m² and 2nd coat with Acrylic emultion top coat which can be tinted to any colour @ 0.17L/m², including 2 coats DFT will be min. 170 microns, The material having followed technical properties: Attains hairline crack bridging up to 2 mm as per EN 1062 part 7, Elongation of >100 % as per ASTMD 412; Tensile strength 2.50 Mpa per ASTM D 412, including priming the surface with 1 coat of Efflorescence resistant penetrating primer dilute with water in the ratio 2:1 spreading at the rate of 0.125 l/m² in the SSD condition. |
| 65 | FW-SS-AHS-2leg) Providing two legged scaffolding using 15cm diameter casurina props or best quality bamboo posts of 4m overall length (3m height + 0.50m projection + 0.50m into the ground ) FW-SS-AHS-8.0m)c).8.00 m height in addition of 2.5m ht |
| 66 | WS-IN-CP-LBT) Supplying and fixing of 15mm dia C.P Tap (Long body Tap) of Best quality including cost of tap with required specials and labour for fixing etc, all complete and as directed by the departmental officers., (The quality and brand of fittings should be got approved from Executive Engineer before use). |
| 67 | WS-IN-CP-SBT) Supplying and fixing of 15mm dia C.P Tap (Short body Tap) of Best quality including cost of tap with required specials and labour for fixing etc, all complete and as directed by the departmental officers., (The quality and brand of fittings should be got approved from Executive Engineer before use). |
| 68 | PA-CE-WW-SL 2C) White washing Two coat using clean shell lime slaked including cost of lime, gum, blue, brushes, including scaffolding, thorough scrapping and washing with soap, soda water etc., complete in all respects. |
| 69 | PA-IN-PEP-2C BPC) Painting the false ceilling / New walls with two coats of 1st class ready mixed PLASTIC EMULSION PAINT of best approved quality colour and shade including a priming coat over cement plastered surface including clean removal of dirt and dust etc., complete including cost of necessary brushes, labour charges, putty etc., complying with relevant standard specification. (The paint should be supplied by the contractors at his own cost.The quality and shade of the paint should be got approved from the Executive Engineer before use.) |
| 70 | PA-IN-PEP-OW W P) Painting old walls two coats with ready mixed plastic emulsion paint of first class quality paint of approved colour and shade for outer wall and other similar works with priming coat through scrapping including cost of necessary brushes, labour charges, patty etc., complying with relevant standard specification. (The paint should be supplied by the contractors at his own cost.The quality and shade of the paint should be got approved from the Executive Engineer before use.) |
| 71 | PA-Ex-EEP-OW W P) Painting old walls two coats with Exterior emulsion paint of first class quality paint of approved colour and shade for outer wall and other similar works with priming coat through scrapping including cost of necessary brushes, labour charges, patty etc., complying with relevant standard specification. (The paint should be supplied by the contractors at his own cost.The quality and shade of the paint should be got approved from the Executive Engineer before use.) |
| 72 | PA-IN-OWP-2C EP) Painting the old wood work with two coats of approved Ist class synthetic enamel paint including thorough scrapping the old paint using sand paper as required by the departmental officers including cost of material, labour for painting, supplying etc., all complete as directed by the departmental officers. (the paint quality and shade should be got approved by Executive Engineer before using.) |
| 73 | PA-Ex-OIP-2C EP) Painting the old Iron work and other similar works such as PVC / ASTM Pipes, Kerb Stone and grills with two coats of approved first class synthetic enamel ready mixed paint of approved quality and brand over the through scrapped surface including scrapping the existing surface the paint should be supplied by the contractor at his own cost, (The quality and the brand of paint should be got approved by the Executive Engineer before use) complying with relevant standard specifications. |
| 74 | WS-IN/EX-PVC-(6 kg/ cm²)/(10 kg/ cm²)) Supplying of 25 mm dia PVC pipes 10 Kg/cm² including all specials etc., completed for casing pipes for 4.0 sq mm submersible flat cable and as directed by the departmental officers. BGLWS-IN/EX-PVC-25)c.25mm dia |
| 75 | WS-Ex-BWSM-TP) Supply and delivery of clear water vertical wet type (Three Phase) submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 without panel board as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes.The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % etc. complete complying with relevant standard specifications and as directed by the departmental officers. (The quality and brand should be got approved from the Executive Engineer before use)WS-Ex-BWSM-50 x 175)Duty - lpm x m - 50 x 175 |
| 76 | WS-Ex-DOL-TPPB) THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ (± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). WS-Ex-DOL-5 HP) 5 HP |
| 77 | WS-Ex-FCC-3c) Supply and laying of PVC insulated and sheathed following core and sq.mm flat type copper cable confirming to IS 694/1990,cable for submersible motor etc., all complete and as directed by the departmental officers. (The materials should be got approved from the Executive Engineer before use)WS-Ex-FCC-3x4)c) 3 core 4 sq.mm flat type copper cable |
| 78 | WS-Ex-LC-S BW/OW) Labour charges for the erection of submersible pumpset in borewell/openwell UPTO 5 HP |
| 79 | WS-Ex-UPVC CP-CP) supplying of following dia upvc column pipe for borewell including cost of all materials of best approved superior quality with isi mark etc all complete and as directed by the departmental officers. (the quality of upvc column pipe should be got approved from the executive engineer before use)WS-Ex-UPVC CP-32) b. 32mm Column Pipe |
| 80 | WS-EX-MS CS-CS) Supply and fixing of borewell MS Clamp sets suitable for 150 mm dia borewell etc., all complete and as directed by the departmental officers. |
| 81 | WS-IN/EX-GI-65) Supplying and laying of 65mm dia GI pipe \\"B\\" class with ISI mark for Below ground level including cost of Eatrh work excavation and refilling, labour charges, etc., all complete and as directed by the departmental officers. |
| 82 | WS-IN/EX-P-Dia) supplying and laying of following dia pipe including cost of all materials of best approved superior quality with isi mark etc all complete and as directed by the departmental officers. (the pipe should be got approved from the executive engineer before use)WS-IN/EX-GI-50)f. 50mm dia GI Pipe |
| 83 | WS-IN/EX-Spl PVC / UPVC / CPVC / GI / CI / GM / MS/SS-Dia) Supply and fixing of following dia PVC/UPVC/CPVC/GI/CI/GM/MS/SS Specials of best approved quality,with ISI mark including cost and conveyence and fixing in position etc., all complete in all respects complying with relevant standard specification and as directed by the departmental officer (The brand and quality of the Specials should be got approved from EE before use)WS-IN/EX-GI EL-50)f.50 mm dia GI Elbow |
| 84 | WS-IN/EX-GI HN-50)f.50 mm dia GI Hex Nipple |
| 85 | WS-IN/EX-GI Un-50)f.50 mm dia GI Union |
| 86 | WS-IN/EX-GI B-50)f.50 mm dia GI Bend |
| 87 | WS-IN/EX-GI TEE-50)f.50 mm dia GI Tee |
| 88 | 50 mm dia GI Coupling |
| 89 | WS-IN/EX-GM NRV-50)f.50 mm dia Gun Metal Non return Valve |
| 90 | WS-IN/EX-GM GV-50)f.50 mm dia Gun Metal Gate Valve |
| 91 | Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of suitable schedule (40/60/80) including the cost of suitable PVC/UPVC/GI specials /GM specials like Elbow, Tee reducers, Plug, union, bend, coupler, nipple/ GM gate valve, check and wheel valve etc., wherever required Below Ground Level including earth work excavation, cutting, threading, laying, jointing, aligning to proper gradient lowering in trench, conveying the pipes and specials, cost of pipes and specials solvent cement resin, sand paper, barricading, pumping, dewatering to watch and ward and cost of labour etc., all complete (the pipes and special quality and brand should be got approved by the EE before laying)50mm dia ASTM pipe |
| 92 | WS-Ex-Ny R-BW) supply and delivery of required dia nylon rope of superior quality for submersible pumpset in borewell and as directed by the departmental officers (the quality of nylon rope should be got approved by the executive engineer before supply) Please Enable Macros to View BoQ information |