|
| 1 | Motor & Pump:-Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class \\"F\\" insulation 55 KW/75 HP , 6 Pole , 980 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 35x35 Size Pump set having 1400 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site (Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) |
| 2 | Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class \\"F\\" insulation 75 KW/100 HP , 8 Pole , 740 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 40x45 Size Pump set having 2000 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site (Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) |
| 3 | Supplying , installation, testing and commissioning of Sound Proof Steel enclosure Water Cooled Engine coupled with Alternator 320KVA/256 KW silent DG Generator set including Base frame, Radiator/Heat Exchanger/Fuel Tank/ Control Panel /AMF panel, fuel piping foundation, all interconnections, loop Earthing, Silencer completed all as per CPWD/CPCB norms with standard accessories etc. as required. (Make:- Crompton Greaves/ Kirloskar/ Cummins or as approved by Engineer-in-charge) |
| 4 | Supplying, Installation, Testing and commissioning of 2 Tonne capacity Single Girder E.O.T. Crane comprising of Main Girder, End carriages -02 nos with long travel motors – 02 Nos, 01 Nos 2 Tonne capacity Wire Rope Electric Hoist, pendant controlled along with brakes, limit switches and electric panel. All motors i.e. Hoisting/ Lowering, cross travel and long travel shall be compatible with VVVF drive and the speeds can be adjusted from zero to maximum speed. The complete system includes erection of columns, LT Girders, LT rail/ Sq Bar, 01 no DSL system (Shrouded type).(MAKE: - GLOBE/ WH BRADY/ GARLIC) |
| 5 | M.S. Pipes:-Manufacturing , Supplying, erection & commissioning of Mild Steel ERW, (Electric Resistance welded) Pipe fabricated/manufactured out of Fe410 Mild Steel Grade 330 as per IS: 3589 of reputed & approved make , including painting with epoxy paint inside and outside surface with two coats of anticorrosive paint of approved brand and manufacture : all conforming to relevant IS codes: complete in all respect and with upto date amendments in relevant IS codes: (Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge)a) 900mm nominal dia pipes of 10mm thick complete as required at site. |
| 6 | b) 350mm nominal dia pipes of 6mm thick complete as required at site. |
| 7 | c) 400mm nominal dia pipes of 6mm thick complete as required at site. |
| 8 | d) 450mm nominal dia pipes of 6mm thick complete as required at site. |
| 9 | MS Flanges:-Manufacturing, Supplying, fixing & welding of following sizes M.S. Flanges completed etc. as required at site.a) 900mm dia. & 25mm thickness. |
| 10 | b) 350mm dia. & 20mm thickness. |
| 11 | c) 400mm dia. & 20mm thickness. |
| 12 | d) 450mm dia. & 20mm thickness. |
| 13 | MS Bends:-Manufacturing, Supplying, fixing & welding of following sizes M.S. Bends completed etc. as required at site.a) 900mm dia. |
| 14 | b) 350mm dia. |
| 15 | c) 400mm dia. |
| 16 | d) 450mm dia. |
| 17 | MS Dummy Flanges:-Manufacturing, Supplying & fixing of M.S. Dummy Flanges of following sizes completed etc. as required at site.a) 900mm dia. & 25mm thickness. |
| 18 | C.I. Sluice Valves:-Providing & Fixing of following size Cast Iron Sluice gate Valve suitable for Pressure 1.6 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)a) 350 mm nominal dia. |
| 19 | b) 450 mm nominal dia. |
| 20 | C.I. Non Return Valves :-Providing & Fixing of following size Cast Iron Non Return Valve suitable for Pressure 1.6 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)a) 350 mm nominal dia. |
| 21 | b) 400 mm nominal dia. |
| 22 | Nut/Bolts/Washers:- Manufacturing & Supplying of Nut,Bolts & Washers etc. of size 7/8\\" x 6\\" as required at site. |
| 23 | Rubber Gaskets:-Manufacturing, Supplying & Fixing of Rubber Gasket of thickness 6mm or more for following sizes M.S. Pipeline Flange as required at site.a) 900mm nominal dia. |
| 24 | b) 350mm nominal dia. |
| 25 | c) 400mm nominal dia. |
| 26 | d) 450mm nominal dia. |
| 27 | Vaccum Pump:-Supplying, Installation, Testing and Commissioning of DV-50 Vaccum Pump set having C.I. casing and C-40 shaft with 10 H.P. energy efficiency LV motor, 3 phase, 415volt 50hz, 1500RPM +/- 5%, TEFC induction motor mounted on suitable size M.S. base frame coupled on existing foundation with all accessories like ML 1.5 starter, anti vibration mounting pad, coupling, nut-bolts & packing etc. complete in all respect i/c providing, fitting & testing of heavy class M.S. pipe of 50mm dia. of required length with necessary gate valve and mountings etc. for charging of pump sets. ( Pump:- Kirloskar make or as approved by Engineer-in-charge) (Motor:- Kirloskar/Crompton /ABB or as approved by Engineer-in-charge) (Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge) |
| 28 | Fabrication Supply Installation Testing and Commissioning of Main L.T Panel suitable for 415 Volt, 3 Phase 4 Wire System, 50Hz AC Supply. Panel Shall be fabricated out of 1.6MM thick CRCA Sheet for load bearing and non load bearing members, Gland Plate shall be fabricated out of 2MM thick CRCA Sheet. Panel shall be Powder coated with RAL 7032 Shade for doors and Body and have suitable solid links for Incoming ond Outgoing of the ACB with Electrical Grade Aluminium of 1000 Ampere Capacity supported on DMC/SMC Bus Bar Supports. Earthing shall be done with 25 X 5MM G.I Strip running acroos the Panel Length. The Control Wiring for Metering and Display Instruments shall be done with PVC Insulated 1.1KV Grade multi stranded copper wire of 2.5 Sqmm. Proper Ventilation system for heat disipation shall be provided with Panel including ventialtion fan and louvers. The Panel Shall not be less than 1875 X 2000 X 750 (H,L&D) The Panel shall be fitted with the following switchgear & instruments as mentioned below:-Incoming:-a) 1000A TP ACB, Manually Type with following protection features such as Overload and Shor Circuit protectionb) Digital Type Multifuntion Meter, bearing Cl 1 Accuracy without RS485 Portc) Phase Indication Lamp for R-Phase, Y-Phase and B-Phase, 240V A.Cd) ACB ON and OFF Indication Lampse) 6A SP MCB, 10KA Breaking Capacity for Protection and Control Circuitf) 1 Set of 1000/5 CT, CL-1.0, 15VA Burden Tape Wound Outgoing:-a) 55KW Star Delta Starter with ML4 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosb) 30KW Star Delta Starter with ML3 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosc) 400A TP MCCB, 36KA Breaking Capacity having thermal Magnetic Release with O/L and S/C Protection : 4 Nosd) 200A TP MCCB, 25KA Breaking Capacity having thermal Magnetic Release with O/L and S/C Protection : 1 Nos.e) 125A TP MCCB, 25KA Breaking Capacity having thermal Magnetic Release with O/L and S/C Protection : 1 Nos.f) 100A TP MCCB, 25KA Breaking Capacity having thermal Magnetic Release with O/L and S/C Protection : 4 Nos. |
| 29 | Supplying, installation, testing & commissioning of Cubical Type Phase sequence corrector suitable for 415 Volt, 3 Phase 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2mm thick CRCA sheet of size for frame work and covers, having gland plate less than 3mm including cleaning and finishing complete with powder coating in approved shade, having links not less 600A capacity. the Bus bar support (wherever required) with short curcuit withstand capacity of 31 MVA for 1 sec. Entire panel shall have a common earth bus of suitable size at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with requires size of Aluminium Bus bar (wherever required) and control wiring shall be done with 2.5 sq.mm PVC insulated copper conductor single core cables. Inclusing providing and fixing the following switch Gear. A) Materiala) 580A Three Pole Power Contactors, AC3 Duty, Coil voltage 220 V A.C: 2 Nos. (Make:- ABB/L&T/C&S)b) LED type indication Lamps RYB (3 set) Aux. Supply: 220V A.C c) Control Miniture Circuit Breaker (3 Nos.) SP, 10KA : 6A d) Single Phase Digital Type Ampere Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 accuracy, CT-Input-5A, Aux. Volt-220V,AC e) Ampere Selector Switch (1No.) Rating : 6Af) Single Phase Digital Type Volt Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 Accuracy, Range:- 0-500 V, Aux. Volt : 220V, A.C g) Voltage Selector Switch (1No.) Rating : 6A h) Current transformer 600/5A, Single Ratio, Single Core, 1Ø (3 Nos.) , Tape wound, CL-1.0 & 15VA i) LED type indication Lamps ON/OFF (2 set) Aux. Supply: 220V A.C j) Auto/ Manual selector switch (2 Nos.), Rating : 6A k) Phase Sequence correction relay (1 Nos.) Aux Volt :220V, A.C l) Audio indication for Phase sequence Reversal (1 Nos.) Hooter : 220V A.C. m) On Delay Timer (1 Nos.) Aux Volt :220V, A.C |
| 30 | Aluminium Conductor LT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE Aluminium Conductor armoured Cable of 650V/1100 KV grade as per IS:7098 with up to date amendment on surface including connection making, taping etc. complete as required. (Make:- National/ Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)a) 4C x 185 sqmm |
| 31 | Supplying & fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth busbar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)a) 6 way, Double door |
| 32 | b) 8way, Double door |
| 33 | Supplying and fixing metal box of 100mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 34 | Supplying, installation, testing & commissioning of 100 watt new generation energy saving & environmental friendly, long life, High-pressure die-cast aluminium housing Flood Light with toughened Glass cover i/c connections complete as required. (Make:- Bajaj/Philips/Crompton/Halonix) |
| 35 | Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required.a) 5/6 amps switch |
| 36 | b) 15/16 amp switch |
| 37 | c) 3 pin 5/6 amp socket outlet |
| 38 | d) 6 pin15/16 amp socket outlet |
| 39 | Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. |
| 40 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 'C' curve, , miniature circuit breaker suitable for inductive load of folloeing poles in the existing MCB DB complete with connections, testing and commissioning etc. as requireda) Single pole |
| 41 | b) Single pole and neutral |
| 42 | Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVS insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular plate, sitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) |
| 43 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.a) 2 x 2.5 sq.mm |
| 44 | b) 2 x 4 sq. mm |
| 45 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make:- Bajaj/ Usha/ Khaitan/ Havells/ orient ) |
| 46 | Supplying, installation, testing & commissioning of prewired Indoor decorative 18/20 watt LED batten extruded aluminum housing & opal diffuser. IP20 complete with all accessories including connection making etc. as required. (Make:- Bajaj/ Halonix/ Havell’s/ Crompton/ Phillips) |
| 47 | Supplying and fixing of following size P.V.C. insulated sheathed /XLPE Aluminum conductor cable of 1.1 KV Grade armoured as per IS:7098 on surface as required. (National, Grandlay, Glouster, Poly-Cab, Phinolex or as approved by Engineer-in-charge). (Size- 2 x 10 sq.mm) |
| 48 | Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 49 | Providing and fixing 25 x 5 mm G.I.strip on surface or in recess including connection etc. as required. |
| 50 | Providing and laying 6 SWG G.I wire on surface or in recess for loop earthing along with existing surface/recessed/conduit/submain wiring/cable etc. as required. |
| 51 | M.S GateFabrication, Erection and Commissioning of M.S. Gate of size 2.50mtr x 1.50mtr with M.S. sheet of thickness 6mm, End Plate(6mm), ISMC 150, ISA (75x75x8mm), Flat Patti (40x6mm), M.S. Square pipe (50x50x4mm) & Fastner etc. or as required at site as per specification and direction of Engineer-in-charge. |
| 52 | Providing & fixing of seal beam of size 150mm (2.5 mtr. long-1 No.) & side channels of size 150mm (1.5mtr Long – 2Nos.) with the help of M.S Clamps, Fastners & Cement Concrete i/c cutting grooves etc. complete as required at site. |
| 53 | Supplying & Fixing of Flat Rubber Seal of size 150mm x 10mm thickness with M.S. Clamp Plate 40mm x 6mm with galvnized Nut/Bolt/Washer in four side of M.S. Flap etc. complete in all respect as required at site. |
| 54 | Providing & fixing of upper channels ISMC 150 of size (2.50 mtr -2 Nos.) with the help of M.S Clamps, Fastners, Cement Concrete etc. complete as required at site. |
| 55 | Manufacturing, supplying & fixing of threaded spindle (EN8) of size 1.50 mtr. long and 40 mm dia i/c providing, fixing, testing & commissioning of gear box system to operate manually by fixing on channel with the help of M.S foundation, Nut & Bolts and spindle wheel etc. complete as required at site. |
| 56 | Construction, maintenance and subsequent removal of earthen bundies including cost of excavation earth filling of E.C. bags with earth, stitching and placing in position for care and diversion of all kinds of water entering or flowing in the drain and pumping out surface as well as under groung seepage water to keep the construction area completely dry for execution of entire work including its execution of work in or under water and or liquid mud wherever required with round the clock watch & ward/maintenance of earthen bundies to keep the working area/site dry complete as per specification & direction of Engineer-in-charge. (Bundies Size- 2.5mtr (L) x 1.5mtr (H) x 0.50mtr (W) x 2 Sides) |
| 57 | Scraping, Cleaning and painting of Complete M.S. Flap Gate with Red oxide primer & CA 50 Black Epoxy paint etc. complete in all respect and as per the direction of Engineer-in-charge. Please Enable Macros to View BoQ information |