| 1 | Clearance of sewer lines and manholes by way of removing silt, slush, solid, garbage, organic, inorganic material, dewatering and disposal with all carriages involved at site to dumping site as directed by Engineer-In-Charge (Complete Job) with all leads and lifts Shrinkage shall be deducted @10% per cum. |
| 2 | Clearance of sump wells, silt chambers, etc by way of removing silt, slush, solid, garbage, organic, inorganic material, dewatering and disposal with all carriages involved at site to dumping site as directed by Engineer-In-Charge (Complete Job) with all leads and lifts Shrinkage shall be deducted @ 10% per cum. |
| 3 | Providing & Laying to level & slope, with proper grade pipes of Class NP3/NP4 of following internal dia & grouting the pipe joints with cement slurry 1: 2 mix (1 cement: 2 fine sand) and also sealing the pipe joints with fixing of Rubber Gaskets incl. Cost of cement, sand, Rubber gaskets and RCC pipes incl. Testing of joints & all carriages of pipes upto site of work (Complete job). |
| 4 | 200mm dia (NP3) |
| 5 | 250mm dia (NP3) |
| 6 | 300mm dia (NP3) |
| 7 | 350mm dia (NP3) |
| 8 | 400mm dia (NP3) |
| 9 | 450mm dia (NP4) |
| 10 | 500mm dia (NP4) |
| 11 | 600mm dia (NP4) |
| 12 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed (All kinds of soil). |
| 13 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres (All kinds of soil). |
| 14 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material |
| 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 16 | Supply & laying of stone soling in horizontal on level including all leads, lifts and carriages upto the site of work complete Job. |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, All work up to plinth level. |
| 18 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone agg. 40mm nominal size) (crushed) |
| 19 | 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone agg. 20mm nominal size) (crushed) |
| 20 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 21 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level |
| 22 | 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 23 | Centering and shuttering incl. Strutting, propping etc and removal of form work for:- |
| 24 | Foundations, footings, bases for columns |
| 25 | Walls (any thickness) including attached pilasters buttresses, plinth and string course etc |
| 26 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
| 27 | Suspended floors, roofs, landings, balconies and access platforms. |
| 28 | Edges of slabs and breaks in floors and walls (Under 20 cm wide) |
| 29 | Above 20 cm wide |
| 30 | Reinforcement for RCC work incl. Straightening cutting, bending, placing in position and binding all complete (Thermo Mechanically Treated Bars). |
| 31 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in (Cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 32 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 33 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately) Second kail wood 35MM. |
| 34 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick (4 mm thick glass pane (weighing not less than 10 kg/sqm). |
| 35 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge (Second class Kail wood 35mm). |
| 36 | Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges with Stainless Steel screws etc. complete (75x47x1.80 mm). |
| 37 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete (100x10 mm). |
| 38 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete (100 mm). |
| 39 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete (Welded). |
| 40 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (Hot finished welded type tubes ). |
| 41 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required ( In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete). |
| 42 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required (In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.). |
| 43 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 44 | 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 45 | 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 46 | 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 fine sand). |
| 47 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm). |
| 48 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete (1 mm thick). |
| 49 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 51 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge (1:3:6 or richer mix (i/c equivalent design mix) |
| 52 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge (1:4:8 or leaner mix (i/c equivalent design mix). |
| 53 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 54 | Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional areas of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 55 | Providing & Fixing of Polycrate Manholes covers & frame including all safe carriages upto site of work (Complete Job). |
| 56 | Providing & laying House connections with the following PVC accessories of ISI make (Prince-B Type) incl. all carriages (Complete Job). |
| 57 | 100mm dia PVC Pipe |
| 58 | 150mm dia PVC Pipe |
| 59 | 100 dia PVC accessories |
| 60 | 150mm dia PVC accessories |
| 61 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete. |
| 62 | Providing, Laying and Spreading of granular Sub Base in trenches in uniform layers including dressing, watering, ramming etc and carriage by tippers to site of work with all leads and lifts (Complete Job). |
| 63 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work |
| 64 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge (In cement mortar). |
| 65 | Dismantling manually/ mechanically including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge (Water bound macadam road). |
| 66 | Dismantling manually/ mechanically including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge (Bituminous road). |
| 67 | Supply of labour (Beldar) for various purposes |
| 68 | Supplying and stacking at site Graded crushed stone aggregate of size (63 mm to 45 mm). |
| 69 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 70 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete |
| 71 | For pipes 100 to 250 mm diameter |
| 72 | For pipes 250 to 300 mm diameter |
| 73 | For pipes 350 to 450 mm diameter Please Enable Macros to View BoQ information |