| 1 | SITC/ITC for below mentioned items ( For ESD Bandipora and Kaloosa Only) |
| 2 | Supply, Erection , testing & commissioning of S.T Pole 11mtr. Long SP-56 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings) |
| 3 | Supply, Erection, testing & commissioning of S.T Pole 9mtr Long SP-33 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings) |
| 4 | Erection, testing & commissioning of S.T Pole 8/9/11mtr Long steel tubular pole including its carriage from Divisisonal Store to Site (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing)(Only ST Pole to be provided by KPDCL and has to be lifted from Store/Substores KPDCL and has to be lifted from stores bandipora) |
| 5 | Supply, Erection, testing & commissioning of S.T Pole 8mtr Long SP-15 with base plate & cap for LT. Strictly as per REC standards(The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing) |
| 6 | Supply, Laying, stringing, tensioning & binding etc of ACSR 100 mmsq (Dog) Conductor |
| 7 | Laying, stringing, tensioning & binding of ACSR 100mmsq (Dog) Conductor including its carriage from Divisisonal Store to Site |
| 8 | Supply, Laying, stringing, tensioning & binding etc of ACSR 50mmsq (Rabbit) Conductor |
| 9 | Laying, stringing, tensioning & binding of ACSR 50mmsq (Rabbit) Conductor including its carriage from Divisisonal Store to Site |
| 10 | Supply, Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor |
| 11 | Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor including its carriage from Divisisonal Store to Site |
| 12 | Providing & fixing of GI Channel/Angle/Flat/v-cross armof sizes including clamps, nuts and bolts |
| 13 | Fixing of GI Channel/Angle/Flat/ v-cross arm of sizes including clamps, nuts and bolts (material to be lifted from Stores/Sub-stores) |
| 14 | Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) or GI Wire 8 SWG for HT/LT pole, 1.2m away from the pole |
| 15 | Fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) for HT/LT pole, 1.2M away from the pole (material to be lifted from Stores/Sub-stores) |
| 16 | SITC of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch complete with GI, Clamps ,Nuts and Bolts etc(To be installed on existing DP Structure) |
| 17 | Installation of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with/without out Earth Switch complete with GI, Clamps Nuts and Bolts etc((To be installed on existing DP Structure)(material to be lifted from Stores/Sub-stores) |
| 18 | Supply,fixing, testing & commissioning of 11KV HG Fuse Set (polymer )as per IS Standards |
| 19 | Supply,fixing, testing & commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 20 | Supply,fixing, testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 21 | Supply,fixing, testing & commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete Set |
| 22 | Supply,fixing, testing & commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with pin, bolt, washer etc complete. |
| 23 | Fixing, testing & commissioning of 11KV Pin Insulators (polymer) 45 KN with GI pins complete. (material to be lifted from Stores/Sub-stores) |
| 24 | Carriage, Installation, testing & commisioing of 25/63/100 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora. |
| 25 | Carriage, Installation, testing & commisioing of 200/250/300 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora. |
| 26 | Providing, Fixing of GI nuts and bolts, . |
| 27 | Fixing of nuts and bolts for fixing of x-arms,v cross arms, and other accessories. (material to be lifted from Stores/Sub-stores) |
| 28 | Painting of poles with one coat of red oxide and two coats of Alm paint. Complete job icluding the cost of paint and red oxide |
| 29 | Supply, Fixing, of LT Shackle insuators with GI Mukey-clamps(50x6mm) icnluding GI nuts and bolts. |
| 30 | SITC of LT Line Spacers(3p4W) |
| 31 | Fixing, of LT Shackle insuators with Mukhi-clamps nuts and bolts. (material to be lifted from Stores/Sub-stores) |
| 32 | Dismantling of ST 8Mtr Long Poles including its carriage to Divisional Stores Bandipora (complete job) |
| 33 | Dismantling of ST 9Mtr Long Poles including its carriage to Divisional Stores (complete job) |
| 34 | Dismantling of PCC Poles including its carraige and safe dumping (complete job) |
| 35 | Dismantling & Re-erection of ST 8Mtr. Long Poles(Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing) |
| 36 | Dismantling & Re-erection of ST 9/11Mtr. Long Poles (Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing) |
| 37 | Dismantling of ACSR 30mmsq including its carriage to Divisional Stores (complete job) |
| 38 | Dismantling of ACSR 50/100 mmsq including its carriage to Divisional Stores Bandipora (complete job) |
| 39 | Dismantling & Re-laying of ACSR 30mmsq at site |
| 40 | Dismantling & Re-laying of ACSR 50mmsq at site |
| 41 | Re-Stringing of loose/fallen Conductor (50mmsq) |
| 42 | Re-Stringing of loose/fallen Conductor (30mmsq) |
| 43 | Branch cutting of trees for route clearance for minimising frquency of faults. |
| 44 | Unloading of 16kVA/25KVA distribution transformer |
| 45 | Loading of 16kVA/25KVA distribution transformer |
| 46 | Unloading of 63kVA/100KVA distribution transformer |
| 47 | Loading of 63kVA/100KVA distribution transformer |
| 48 | Unloading of 200kVA/250kVA/300KVA distribution transformer |
| 49 | Loading of 200kVA/250kVA/300KVA distribution transformer |
| 50 | Mounting/Unmounting of Distribution transformer 63/100/250KVA using Hydraulic Crane where lifting/installation in not possible manually. |
| 51 | Unloading of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc |
| 52 | Loading/Shifting of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc |
| 53 | Supply and fixing of Earthing of sub station-Excavation of earth pit of dia 650 mm & depth 3000mm,installation of earthing pipe of 40mm Nominal bore and 4mm wall thickness and length 2.5 mtr long as per IS 1239 GI strip for neutral earthing of size25x3mm for connection of transformer body,GO set and lighting arrestor as per IS 2629/85,GI nuts and Bolts,refilled with earth enhancement material and earth chamber made of brick masonary with RCC slab cover. |
| 54 | Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 70 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 55 | Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 120 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 56 | Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 300 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 57 | Providing, Installation, testing & commisioning of 3-Phase 4-wire Prodigy Meter (40 -200A), including suitable stand/clamps using channels and Canopy to protect the same from Adverse Weather Conditions (Complete) |
| 58 | Supply, laying, testing & commissiong of 120mmsq AB (HT Cable) (3x120+1x95mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any. |
| 59 | Supply, laying, testing & commissiong of 50mmsq AB (HT Cable) (3x50+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any. |
| 60 | Supply, laying, testing & commissiong of 35mmsq AB (HT Cable) (3x35+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any. |
| 61 | Laying, testing & commissiong of 120/50/35mmsq AB (HT Cable) (material to be lifted from Stores/Sub-stores) |
| 62 | Supply, fixing, testing & commissiong of Mid Span Straight through Jointing kit for 11kV AB Cable suitable for AB Cable of standard make and size conforming to the latest IS Standards |
| 63 | Supply, fixing, testing & commissiong of 11kV Heat Shrinkable Out Door Cable termination Kit for 11kV AB Cable of standard make and size conforming to the latest IS Standards |
| 64 | Supply, Fixing of ' Suspension Clamps with eye Hook (Complete)' of standard make for AB Cable including strips for fixing on poles of required sizes |
| 65 | SITC of 120 mm² AB Cable (3x120+1x25+1x95) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL) |
| 66 | SITC of 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL) |
| 67 | SITC of 70 mm² AB Cable (3x70+1x16+1x50) mm² XLPE (1.1kV, 3+1 C, Al) (Reputed make approved with KPDCL) |
| 68 | SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6)mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 69 | SITC of Insulating Piercing Connectors |
| 70 | SITC of Straight Through Cable Jointing Kit for LT Cables of various sizes |
| 71 | SITC of Pole Mount Service connection box for LT ab cable(SMDB) |
| 72 | Erection/Fixing/Installation of 120/75/50/35 mm² LT AB Cable (material to be lifted from Stores/Sub-stores) |
| 73 | Erection/Fixing/Installation of Galvanised Stay Set (material to be lifted from Stores/Sub-stores) |
| 74 | SITC Streight Throught Joint for Single Core HT Cable of various Sizes |
| 75 | SITC of Outdoor type termination Kit for Single Core HT Cable of various sizes. |
| 76 | SITC Streight Throught Joint for Three Core HT Cable of various Sizes |
| 77 | SITC of Outdoor type termination Kit for Three Core HT Cable of various sizes. |
| 78 | SITC of 11 kV/11 kV THREE CORE,95 mm2 ALUMINIUMCONDUCTOR, XLPE INSULATED, ARMOURED CABLE to be laid in HDPE pipe of appropriate size 1000mm below ground(Cost inclusive of HDPE Pipe to be quoted) |
| 79 | SITC of 1.1 kV TWO CORE, 50 sqmm ALUMINIUM CONDUCTOR, XLPE INSULATED, ARMOURED CABLES to be laid on ground/on existing poles etc as per site requirement |
| 80 | Replacement of Filter Papers Rods of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine |
| 81 | Servicing of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine |
| 82 | Servicing of 2.4/3.5kVA DG Set Kirloskar Make |
| 83 | Supply, Installation ,Testing and Commissioning and operation at sites within the jurisdiction of ED Bandipora (by utilizing skilled mechanics) of 2.8KVA Portable Gensets on hire basis(rate per day, fuel to be provided by KPDCL) |
| 84 | Loading,Carriage to and fro ,Installation ,Testing and Commissioning (by utilizing skilled mechanics) of Portable Gensets (to be provided by the department) from Divisional Stores upto sites within the jurisdiction of ED Bandipora(Rate per day) |
| 85 | Operation and Maintainence (by utilizing skilled mechanics) of 5/25/62.5/100 KVA Portable Gensets (rate per day) |
| 86 | Installation, Testing & commisioing of 10/30/40 watt LED lights including bracket , clamps , nuts & bolts of standard make |
| 87 | Supply, Installation, Testing & commisioing of 20 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make |
| 88 | Supply, Installation, Testing & commisioing of 40 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make |
| 89 | Supply, Installation, Testing & commisioing of 100 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make |
| 90 | Providing, laying of 16mmsq twin core Cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 91 | Providing, laying of 10mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 92 | Providing, laying of 6mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 93 | Providing, laying of 1mmsq PVC single core Cu flexible wire coil (90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 94 | Providing, laying of 1.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 95 | Providing, laying of 2.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 96 | Providing, laying of 4 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 97 | Providing, laying of 6 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 98 | Supply, Installation, Testing & commisioing of 5Amp Switch Socket Combine |
| 99 | Supply,Installation, Testing & commisioing of 32 Amp with DP Switch Socket Combine |
| 100 | Supply, Installation, Testing & commisioing of LED Bulbs 10W with pendent holders |
| 101 | Supply, installation, testing & commissioing of LT Fuse set on 8 No 10kV Post Insulators with direct link of 8x5mm Al flat for Neutral along with clamps and thimbles, nuts and bolts etc as per approved drawings of KPDCL |
| 102 | Supply, Installation, Testing and Commissioning of 0.5 Sq.mm 2 Core Flexible Twisted Wire Red and Black (90 m) |
| 103 | Supply and Installation of 4Pole 100Amp, 415v, 50Hz, Off load Change over switch conforming to latest IS standards of reputed brands like havells, L&T etc. |
| 104 | Supply and Installation of MS Kiosk for Housing of Changeover Switches |
| 105 | Unloading of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores |
| 106 | Loading/shifting of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores |
| 107 | Providing and Laying in position cement concrete ( PCC)(M10 Grade) including centering, shuttering, carriage of material, curing etc |
| 108 | Providing and Laying in position reignforced cement concrete ( RCC)(M20 Grade) including centering, shuttering, carriage of material, curing etc as per drawing(Rebar reignforcement to be provided by the department) |
| 109 | Providing and applying cement plaster (1:4 mix) 12mm thick on walls including surface preparation, scaffolding, curing, and all necessary tools and materials complete as per specifications. |
| 110 | Relaying/Restringing of loose /fallen / low hanging LT/HT AB Cable |
| 111 | Installation of Consumer Metres (Complete Job including connection etc ) (material to be lifted from Stores/Sub-stores) |
| 112 | Shifting of Metres from bare conductor to AB Cable or new line (Complete Job including connection etc ) |
| 113 | SITC/ITC for below mentioned items( for ESD Gurez Only) |
| 114 | Supply, Erection , testing & commissioning of S.T Pole 11mtr. Long SP-56 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings) |
| 115 | Supply, Erection, testing & commissioning of S.T Pole 9mtr Long SP-33 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings) |
| 116 | Erection, testing & commissioning of S.T Pole 8/9/11mtr Long steel tubular pole including its carriage from Divisisonal Store to Site (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing)(Only ST Pole to be provided by KPDCL and has to be lifted from Store/Substores KPDCL and has to be lifted from stores bandipora) |
| 117 | Supply, Erection, testing & commissioning of S.T Pole 8mtr Long SP-15 with base plate & cap for LT. Strictly as per REC standards(The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing) |
| 118 | Supply, Laying, stringing, tensioning & binding etc of ACSR 100 mmsq (Dog) Conductor |
| 119 | Laying, stringing, tensioning & binding of ACSR 100mmsq (Dog) Conductor including its carriage from Divisisonal Store to Site |
| 120 | Supply, Laying, stringing, tensioning & binding etc of ACSR 50mmsq (Rabbit) Conductor |
| 121 | Laying, stringing, tensioning & binding of ACSR 50mmsq (Rabbit) Conductor including its carriage from Divisisonal Store to Site |
| 122 | Supply, Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor |
| 123 | Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor including its carriage from Divisisonal Store to Site |
| 124 | Providing & fixing of GI Channel/Angle/Flat/v-cross armof sizes including clamps, nuts and bolts |
| 125 | Fixing of GI Channel/Angle/Flat/ v-cross arm of sizes including clamps, nuts and bolts (material to be lifted from Stores/Sub-stores) |
| 126 | Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) or GI Wire 8 SWG for HT/LT pole, 1.2m away from the pole |
| 127 | Fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) for HT/LT pole, 1.2M away from the pole (material to be lifted from Stores/Sub-stores) |
| 128 | SITC of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch complete with GI, Clamps ,Nuts and Bolts etc(To be installed on existing DP Structure) |
| 129 | Installation of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with/without out Earth Switch complete with GI, Clamps Nuts and Bolts etc((To be installed on existing DP Structure)(material to be lifted from Stores/Sub-stores) |
| 130 | Supply,fixing, testing & commissioning of 11KV HG Fuse Set (polymer )as per IS Standards |
| 131 | Supply,fixing, testing & commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 132 | Supply,fixing, testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 133 | Supply,fixing, testing & commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete Set |
| 134 | Supply,fixing, testing & commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with pin, bolt, washer etc complete. |
| 135 | Fixing, testing & commissioning of 11KV Pin Insulators (polymer) 45 KN with GI pins complete. (material to be lifted from Stores/Sub-stores) |
| 136 | Carriage, Installation, testing & commisioing of 25/63/100 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora. |
| 137 | Carriage, Installation, testing & commisioing of 200/250/300 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora. |
| 138 | Providing, Fixing of GI nuts and bolts, . |
| 139 | Fixing of nuts and bolts for fixing of x-arms,v cross arms, and other accessories. (material to be lifted from Stores/Sub-stores) |
| 140 | Painting of poles with one coat of red oxide and two coats of Alm paint. Complete job icluding the cost of paint and red oxide |
| 141 | Supply, Fixing, of LT Shackle insuators with GI Mukey-clamps(50x6mm) icnluding GI nuts and bolts. |
| 142 | SITC of LT Line Spacers(3p4W) |
| 143 | Fixing, of LT Shackle insuators with Mukhi-clamps nuts and bolts. (material to be lifted from Stores/Sub-stores) |
| 144 | Dismantling of ST 8Mtr Long Poles including its carriage to Divisional Stores Bandipora (complete job) |
| 145 | Dismantling of ST 9Mtr Long Poles including its carriage to Divisional Stores (complete job) |
| 146 | Dismantling of PCC Poles including its carraige and safe dumping (complete job) |
| 147 | Dismantling & Re-erection of ST 8Mtr. Long Poles(Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing) |
| 148 | Dismantling & Re-erection of ST 9/11Mtr. Long Poles (Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing) |
| 149 | Dismantling of ACSR 30mmsq including its carriage to Divisional Stores (complete job) |
| 150 | Dismantling of ACSR 50/100 mmsq including its carriage to Divisional Stores Bandipora (complete job) |
| 151 | Dismantling & Re-laying of ACSR 30mmsq at site |
| 152 | Dismantling & Re-laying of ACSR 50mmsq at site |
| 153 | Re-Stringing of loose/fallen Conductor (50mmsq) |
| 154 | Re-Stringing of loose/fallen Conductor (30mmsq) |
| 155 | Branch cutting of trees for route clearance for minimising frquency of faults. |
| 156 | Unloading of 16kVA/25KVA distribution transformer |
| 157 | Loading of 16kVA/25KVA distribution transformer |
| 158 | Unloading of 63kVA/100KVA distribution transformer |
| 159 | Loading of 63kVA/100KVA distribution transformer |
| 160 | Unloading of 200kVA/250kVA/300KVA distribution transformer |
| 161 | Loading of 200kVA/250kVA/300KVA distribution transformer |
| 162 | Mounting/Unmounting of Distribution transformer 63/100/250KVA using Hydraulic Crane where lifting/installation in not possible manually. |
| 163 | Unloading of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc |
| 164 | Loading/Shifting of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc |
| 165 | Supply and fixing of Earthing of sub station-Excavation of earth pit of dia 650 mm & depth 3000mm,installation of earthing pipe of 40mm Nominal bore and 4mm wall thickness and length 2.5 mtr long as per IS 1239 GI strip for neutral earthing of size25x3mm for connection of transformer body,GO set and lighting arrestor as per IS 2629/85,GI nuts and Bolts,refilled with earth enhancement material and earth chamber made of brick masonary with RCC slab cover. |
| 166 | Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 70 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 167 | Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 120 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 168 | Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 300 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 169 | Providing, Installation, testing & commisioning of 3-Phase 4-wire Prodigy Meter (40 -200A), including suitable stand/clamps using channels and Canopy to protect the same from Adverse Weather Conditions (Complete) |
| 170 | Supply, laying, testing & commissiong of 120mmsq AB (HT Cable) (3x120+1x95mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any. |
| 171 | Supply, laying, testing & commissiong of 50mmsq AB (HT Cable) (3x50+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any. |
| 172 | Supply, laying, testing & commissiong of 35mmsq AB (HT Cable) (3x35+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any. |
| 173 | Laying, testing & commissiong of 120/50/35mmsq AB (HT Cable) (material to be lifted from Stores/Sub-stores) |
| 174 | Supply, fixing, testing & commissiong of Mid Span Straight through Jointing kit for 11kV AB Cable suitable for AB Cable of standard make and size conforming to the latest IS Standards |
| 175 | Supply, fixing, testing & commissiong of 11kV Heat Shrinkable Out Door Cable termination Kit for 11kV AB Cable of standard make and size conforming to the latest IS Standards |
| 176 | Supply, Fixing of ' Suspension Clamps with eye Hook (Complete)' of standard make for AB Cable including strips for fixing on poles of required sizes |
| 177 | SITC of 120 mm² AB Cable (3x120+1x25+1x95) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL) |
| 178 | SITC of 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL) |
| 179 | SITC of 70 mm² AB Cable (3x70+1x16+1x50) mm² XLPE (1.1kV, 3+1 C, Al) (Reputed make approved with KPDCL) |
| 180 | SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6)mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 181 | SITC of Insulating Piercing Connectors |
| 182 | SITC of Straight Through Cable Jointing Kit for LT Cables of various sizes |
| 183 | SITC of Pole Mount Service connection box for LT ab cable(SMDB) |
| 184 | Erection/Fixing/Installation of 120/75/50/35 mm² LT AB Cable (material to be lifted from Stores/Sub-stores) |
| 185 | Erection/Fixing/Installation of Galvanised Stay Set (material to be lifted from Stores/Sub-stores) |
| 186 | SITC Streight Throught Joint for Single Core HT Cable of various Sizes |
| 187 | SITC of Outdoor type termination Kit for Single Core HT Cable of various sizes. |
| 188 | SITC Streight Throught Joint for Three Core HT Cable of various Sizes |
| 189 | SITC of Outdoor type termination Kit for Three Core HT Cable of various sizes. |
| 190 | SITC of 11 kV/11 kV THREE CORE,95 mm2 ALUMINIUMCONDUCTOR, XLPE INSULATED, ARMOURED CABLE to be laid in HDPE pipe of appropriate size 1000mm below ground(Cost inclusive of HDPE Pipe to be quoted) |
| 191 | SITC of 1.1 kV TWO CORE, 50 sqmm ALUMINIUM CONDUCTOR, XLPE INSULATED, ARMOURED CABLES to be laid on ground/on existing poles etc as per site requirement |
| 192 | Replacement of Filter Papers Rods of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine |
| 193 | Servicing of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine |
| 194 | Servicing of 2.4/3.5kVA DG Set Kirloskar Make |
| 195 | Supply, Installation ,Testing and Commissioning and operation at sites within the jurisdiction of ED Bandipora (by utilizing skilled mechanics) of 2.8KVA Portable Gensets on hire basis(rate per day, fuel to be provided by KPDCL) |
| 196 | Loading,Carriage to and fro ,Installation ,Testing and Commissioning (by utilizing skilled mechanics) of Portable Gensets (to be provided by the department) from Divisional Stores upto sites within the jurisdiction of ED Bandipora(Rate per day) |
| 197 | Operation and Maintainence (by utilizing skilled mechanics) of 5/25/62.5/100 KVA Portable Gensets (rate per day) |
| 198 | Installation, Testing & commisioing of 10/30/40 watt LED lights including bracket , clamps , nuts & bolts of standard make |
| 199 | Supply, Installation, Testing & commisioing of 20 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make |
| 200 | Supply, Installation, Testing & commisioing of 40 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make |
| 201 | Supply, Installation, Testing & commisioing of 100 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make |
| 202 | Providing, laying of 16mmsq twin core Cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 203 | Providing, laying of 10mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 204 | Providing, laying of 6mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 205 | Providing, laying of 1mmsq PVC single core Cu flexible wire coil (90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 206 | Providing, laying of 1.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 207 | Providing, laying of 2.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 208 | Providing, laying of 4 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 209 | Providing, laying of 6 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA |
| 210 | Supply, Installation, Testing & commisioing of 5Amp Switch Socket Combine |
| 211 | Supply,Installation, Testing & commisioing of 32 Amp with DP Switch Socket Combine |
| 212 | Supply, Installation, Testing & commisioing of LED Bulbs 10W with pendent holders |
| 213 | Supply, installation, testing & commissioing of LT Fuse set on 8 No 10kV Post Insulators with direct link of 8x5mm Al flat for Neutral along with clamps and thimbles, nuts and bolts etc as per approved drawings of KPDCL |
| 214 | Supply, Installation, Testing and Commissioning of 0.5 Sq.mm 2 Core Flexible Twisted Wire Red and Black (90 m) |
| 215 | Supply and Installation of 4Pole 100Amp, 415v, 50Hz, Off load Change over switch conforming to latest IS standards of reputed brands like havells, L&T etc. |
| 216 | Supply and Installation of MS Kiosk for Housing of Changeover Switches |
| 217 | Unloading of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores |
| 218 | Loading/shifting of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores |
| 219 | Providing and Laying in position cement concrete ( PCC)(M10 Grade) including centering, shuttering, carriage of material, curing etc |
| 220 | Providing and Laying in position reignforced cement concrete ( RCC)(M20 Grade) including centering, shuttering, carriage of material, curing etc as per drawing(Rebar reignforcement to be provided by the department) |
| 221 | Providing and applying cement plaster (1:4 mix) 12mm thick on walls including surface preparation, scaffolding, curing, and all necessary tools and materials complete as per specifications. |
| 222 | Relaying/Restringing of loose /fallen / low hanging LT/HT AB Cable |
| 223 | Installation of Consumer Metres (Complete Job including connection etc ) (material to be lifted from Stores/Sub-stores) |
| 224 | Shifting of Metres from bare conductor to AB Cable or new line (Complete Job including connection etc ) |
| 225 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(As per Drawing to be provided by KPDCL) |
| 226 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 227 | Hire Charges for mentioned items (ESD Bandipora Kaloosa and Gurez) |
| 228 | Hire, operation and maintenance charges for Installation, decorating and operation for 5 days of fancy decoration mala Lights (12m long) (Orange+White+Green) at various places within the jurisdiction of ED Bandipora like Minisectt, Town hall, SP Office, Kangri Chowk , Gurez Bridge, Gurez Mini Sectt. etc |
| 229 | Hire, operation and maintenance charges for for Installation and commissioning of copper cable 2.5mm sq for 5 days, for providing connection to equipment/lights/buildings etc |
| 230 | Hire, operation and maintenance charges for for Installation and commissioning of copper cable 1mm sq for 5 days, for providing connection equipment/lights/buildings etc |
| 231 | Hire, operation and maintenance charges for for 5 days for Standing fan/Ceiling fan 1200mm Sweep with Allied wiring and switches including the Installation and Operation for different events like Independence day etc within the jurisdiction of ED Bandipora |
| 232 | Hire charges per day for providing of Pick up Truck along with driver including toll taxes, repair and maintenance for transporation of men and material ( as and when required ).(Fuel will be provided by the department as per milage fixed by JKSMGD) |
| 233 | Charges per day for Operation and Maintainence (by utilizing skilled mechanics) of Portable Gensets of various capacities |
| 234 | Providing of labours to do non technical manual work (7 Hours per day) Please Enable Macros to View BoQ information |