| 1 | Line Material parts |
| 2 | RS Joist pole 150x150(13 Mtr long) |
| 3 | 11 KV Vcross arm |
| 4 | Top bracket (100x50x6)mm GI channel |
| 5 | Conductor 55 Sq.mm ACSR Rabbit PVC Insulated |
| 6 | PG Clamp for 55 sq.mm AAA Conductor |
| 7 | 11 KV Pin insulator Polymer |
| 8 | HW Fittings(B&S) 70 KN,3 bolt |
| 9 | Disc Insulator(B&S) 70 KN Polymer |
| 10 | Spike (GI) (using 50x6mm flat) |
| 11 | Back clamp For GI F/11KV Vcross arm |
| 12 | Earthing of Support( Coil type) |
| 13 | Top Channel 100x50x6 mm,9.56 Kg/Mtr |
| 14 | Fish plate 50x6mm,2.36 kg/mtr |
| 15 | Double pole GI belting channel 75x40x4.8mm |
| 16 | GI Bracing angle 50x50x6mm 4.5kg/mtr |
| 17 | Danger Plate |
| 18 | Back clamp for danger plate 25x3 mm |
| 19 | HT Stay set(Complete) |
| 20 | HT Stay Insulator Type-C(2 Nos) |
| 21 | HT Stay Clamp,50x8 mm Flat,3.14 Kg/Mtr |
| 22 | 7/10 SWG Stay wire 15 Kg/Stay |
| 23 | GI pipe earthing 40mm 3mtr long |
| 24 | 50x6mm GI flat for earthing,2.36kg/mtr |
| 25 | GI nut,bolt & washer of different sizes |
| 26 | Black Paint |
| 27 | Yellow colour paint for Background |
| 28 | Civil work for Line Part |
| 29 | Fixing of complete 11 KV line complete set |
| 30 | Concreting of 11 KV Pole ratio(1:1.5:3)(500mmx500mmx1800 mm)-7 Nos |
| 31 | Concreting of earth pit ratio( 1:1.5:3)(500x500x450mm)-7 Nos |
| 32 | Concreting of stay ratio(1:1.5:3)(500x500x1500mm)-5 Nos |
| 33 | Sub-Station Part |
| 34 | RS Joist pole 150x150(11 Mtr long) |
| 35 | Top Channel 100x50x6 mm,9.56 Kg/Mtr |
| 36 | Fish plate 50x6mm,2.36 kg/mtr |
| 37 | GI channel 75x40x4.8mm (3000mm long) |
| 38 | GI angle 50x50x6mm (1282mm long) |
| 39 | GI flat for earthing(50x6) 2.36kg/mtr. |
| 40 | 25 KVA,11/0.4 KV (AL) Transformer BIS Level-ll |
| 41 | LT Distribution box with MCCB ,Aluminium Busbar 2 bay |
| 42 | 55 Sq.mm insulated AAAC |
| 43 | AB Swtich(11kv,200A,3pole ,50Hz) |
| 44 | HG fuse(11kv,200A,3pole) |
| 45 | PG Clamp for 55 sq.mm AAA Conductor |
| 46 | Disc Insulator(B&S) 70 KN Polymer |
| 47 | HW Fittings(B&S) 70 KN,3 bolted |
| 48 | Lightning Arrester (12kv,10KA)Station Class |
| 49 | 11 KV Pin insulator Polymer |
| 50 | HT Stay set(Complete) |
| 51 | HT Stay Clamp |
| 52 | HT Stay Insulator Type-C |
| 53 | 7/10 SWG Stay wire,Grade-2( 15 Kg/Stay) |
| 54 | 40mm Nominal bore GI pipe(medium gauge) |
| 55 | GI nut,bolt & washer of different sizes |
| 56 | GI barbed wire/Anticlimbing device |
| 57 | Back clamp for Anticlimbing Device(25x3 mm) |
| 58 | Danger Plate 11KV |
| 59 | Name plate |
| 60 | Yellow colour paint for Background |
| 61 | Black colour paint for numbering |
| 62 | Back clamp For Danger plate (25x3mm ) |
| 63 | CIVIL WORK |
| 64 | Concreting of 11 KV Pole ratio(1:1.5:3)(500mmx500mmx1800 mm)-7 Nos |
| 65 | Concreting of earth pit ratio( 1:1.5:3)(500x500x450mm)-5 Nos |
| 66 | Concreting of stay ratio(1:1.5:3)(500x500x1500mm)-2 Nos |
| 67 | Fixing of Stay set |
| 68 | Construction Earthing chamber |
| 69 | Supply and Erection of GI fencing with gate |
| 70 | Plinth for LT Distribution box Please Enable Macros to View BoQ information |