| 1 | Taking down cement plaster of any description on brick/ Stone Walls or from Concrete Surfaces incl raking out joints, hacking for key, scrubbing down with water etc all as specified and removing unserviceable material outside premises complete all as specified and as directed. |
| 2 | Material and labour for applying one coat of epoxy resin (FAIR BOND EP) on old Concrete/Brick/Stone surfaces @ 0.30Kg/Sqm including preparation of surfaces as per manufacturer's instruction and applying 25 mm thick (average thickness) of cement and sand (fine grith) in ratio mixed with chloride free spray concrete plasticizer (spray crete) as per manufacturer's instruction with guniting machine of pressure capacity not less than 5 kg per Sqm and finished the surface even and smooth in CM 1:4 complete all as specified and directed for UG Sump P-16 Picket Hill. |
| 3 | M &L for Grouting in Brick/RCC Wall/StoneWall/floor/roof through PVC nipples at a spacing of 45 to 60 C/C including drilling injection points to a depth of 75-100mm, providing 10 mm dia PVC nipples and pressure grouting using with and including cement mixed with plasticizer admixture like FOSROC (model CEBEX 100) or PIDILITE (MODEL 207 PIDICRET 8 AM) @225/GMS?50KGS oc cement to fill up all Capillaries/voids/honevombing, nozzles to be sealed with sealing with pressure of 2 to 4 Kg/sQM cm and continued till refusal. After instruction complete all as specified and directed |
| 4 | GI wire netting 0.90 mm dia and 12 mm mesh lathing to wood or metal studding, joints etc . In walls ceiling, stacing, beams etc including all laps, cutting and waste |
| 5 | M&L for 15mm thick rendering in two coats on stone/ brick/ concrete surfaces finished even and smooth without using extra cement etc. 1st coat 10 mm thick in CM 1:6 and 2nd coat 5mm thick in CM 1:4 mix with water proofing compound as per manufacturer instructions complete all as specified and as directed. Note : WPC shall measured and paid Seprately |
| 6 | M&L for applying two coats of Epoxy water proffing paint including priming coat of water proof based primer applied @ 0.90 liters/10 sqm over new surfaces as per manufacturer's instruction complete all as specified and directed |
| 7 | Supply only Integral water proofing Compound |
| 8 | M&L cutting out cracks to 'V' Section in existing roof or terracing, cleaning out, wetting and filling solidly a hot mixture of bitumen and dry sand in proporation of 1:1 by weight complete allas specified and directed |
| 9 | Demolition of PCC in any description and in any position etc complete etc complete all as specified and dirceted |
| 10 | M&L for 100mm thick plain cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as in floor |
| 11 | M&L for 20mm thick rendering in two coats on stone/ brick/ concrete surfaces (external) finished even and smooth without using extra cement etc. 1st coat 15 mm thick in CM 1:6 and 2nd coat 5mm thick in CM 1:4 mix with water proofing compound as per manufacturer instructions complete all as specified and as directed. Note : WPC shall measured and paid Seprately |
| 12 | M&l for PCC 1:2:4 type B-O using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and direcetd |
| 13 | M&L Rendering 10mm rendering in cement mortar 1:4 on concrete surfaces when concrete is still green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and directed Note : WPC shall measured and paid Seprately |
| 14 | M&L preparation of walls newly plastered surfaces & applying three coat of white wash complete all as specified and directed |
| 15 | Demolition of reinforced Cement Concrete of any description and in any position disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer in charge . ( Reinforcement shall be cut as required to facilitate demolition ) complete all as specified and directed |
| 16 | M&L for precast reinforced cement concrete (1:2;4), type B-1 (using 20 mm graded stone aggregate ) as in cover slab (for manhole etc) and similar articles with plain faces and set in cement mortar (1:4) complete all as specified and directed |
| 17 | M&L for mild steel TMT bars 10mm dia, and over cut to length to shape required ,including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia , or securing with clips complete allas specified and directed. |
| 18 | Demoltion of brickwork or stone/ boulder masonry, built incement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 19 | M&L for Brick work with fly ash bricks straight or curved on plan exc 6m in radius but built in 1:6 cement mortar complete all as specified and as directed. |
| 20 | M&L RCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregates) in .Walls, retaining walls, basement walls, ballast walls and the like;any thickness; above top offootings; including attached plaster and buttresse. (reinforcement to be measured separately) |
| 21 | M&L Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter Please Enable Macros to View BoQ information |