| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out in any type of soil and disposal of excavated earth lead up to 50 m and lift up to 1.5m, complete all as specified and directed. |
| 2 | All as per Sl NO. 01 above but exc 1.5m deep and n exc 3.0 m deep complete all as specified and directed. |
| 3 | All as per Sl NO. 01 above but exc 3.0 m deep and n exc 4.5 m deep complete all as specified and directed. |
| 4 | Excavation in trenches, n. exc 1.5m wide and n. exc 1.5m deep, for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc etc n.exc 10 Sqm on plan and not exc 1.5 m depth and getting out in any type of soil complete all as specified and directed. |
| 5 | Removing excavated material n. exc 50 mtr and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and directed |
| 7 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, drain in soft/loose soil an getting out complete all as specified and directed. |
| 8 | M&L Brickwork with sub class 'B' (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified and directed. |
| 9 | M&L for rendering 10 mm thick in CM 1:4 with on bricks masonry or concrete surfaces on fair faces of brick masonry, finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 11 | M & L TMT bars 5mm dia and over upto and including 10mm dia as in stirrups cut to length bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with and incl mild steel wiere (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 12 | M&L precast Reinforced cement concrete 1:2:4 Type B1 fixed in cm 1:4 in landings, cover slabs (for man holes etc,) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 13 | M&L for loose filling with aggregate of broken bricks of gauge 80 to 150mm in soakage its soakage wells etc complete all as specified and directed. |
| 14 | M&L for loose filling with gravel of broken stone or boulder gauge 40 mm to 80 mm in each layers n exc 15cm thick spreaded, levelled and rammed incl watering complete all as specified and directed. |
| 15 | M&L for loose filling with Moorum/bajri filling in floors or paving, laid in layers n exc 15 cm thick, spread and levelled , complete all as specified and directed. |
| 16 | M&L for Sand filling under floors or in foundations including watering and consolidation in floors or pavings, complete all as specified and directed. |
| 17 | Mild steel framed work such as grill, gratings etc. with ends of bars shouldered and/or rivetted or forged into spikes, framed guard bars,barred iron doors ladders,framed balusters,walk ways,railings,framework of water tanks and similar works conforming to Fe-290 (Gde E-165)complete all as specified and directed. |
| 18 | S&F mild rolled section in joist, channel, angle, or tee section fixed independently without connecting plate etc cut to ordinary length it means within 20 mm of length indicated , complete all as specified and directed. (Gde FE-290 (Gde-E-165) |
| 19 | Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer, complete all as specified and directed. |
| 20 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165,complete all as specified and directed.. |
| 21 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding/ ridges/ gutter to wall, fixed with self tapping screws complete all as specified and directed. |
| 22 | Dismantling posts or struts (wood, Steel, or RCC) any section, including taking out embedded portion, embedded in concrete, brickwork, masonry, etc and making good disturbed ground complete all as specified and directed. |
| 23 | Dismantling timber scantling 40 sq cm and over in section framed work, in any position, complete all as specified and directed. |
| 24 | Dismantling timber scantling 40 sq cm and over in section unframed work, in any position, complete all as specified and directed. |
| 25 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gentries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade Fe-410-W (Gde E- 250,quality-A), complete all as specified and directed. |
| 26 | S & F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates Fe 410-W (Gde- E- 250,quality A), complete all as specified and directed. |
| 27 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc, built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe 410-W (Gde- E- 250) quality- A complete all as specified and directed |
| 28 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 29 | S&F Mild steel screw bolts, dia of neck 16 to 20 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both end to be fitted with washers and one hexagonal or square nut exc 15 cm but n exc 22.5 cm embed in concrete surface, complete all as specified and directed |
| 30 | Dismantling of plain or corrugated steel sheeting,any gauge,thickness,including nanital or similar pattern roof covering and M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 31 | Dismantling of plain or corrugated steel sheeting,any gauge,thickness,including nanital or similar pattern roof covering and M & L for Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 32 | Demolition of brick work or stone /boulder masonry, built in CM, incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed. |
| 33 | M&L for Brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6) complete all as specified and directed. |
| 34 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and smooth without using extra cement complete all as specified and directed.. |
| 35 | M&L Distempering with 1st quality acrylic distemper (ready mixed ) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacturers specification two or more coats over 2mm wall care putty on new surface of wall including preparation of surfaces with complete all as specified and directed. |
| 36 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams flat for fair finished surfaces of concrete,complete all as specified and directed. |
| 37 | M&L for reinforced cement concrete of grade M-20 ,1:1.5:3 nominal mix type A-1 (20 mm graded coarse aggregate size) in beams, cantilevers, bressummers, lintels over 1.5 m span, complete all as specified and directed. |
| 38 | Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including fillets complete all as specified and directed. |
| 39 | S&F Providing and fixing tiled false ceiling of size 595 x 595mm in true horizontal level suspended on interlocking gypric metal grid of hot dipped galvanised steel section (galvanized @ 120 gsm/sqm, both side inclusive) consisting of 3600mm long main 'T' runner size 24x38mm and 0.30mm thick, 1200mm long cross 'T' of size 24 x 25mm and 0.30mm thick, 600mm secondary cross 'T' of size 24 x 25mm and 0.30mm thick, bottom exposed capping of width 24mm of all T-sections shall be of 0.25mm thick PPGl. wall angle is fixed along the perimeters of the ceiling to walls, partitions or columns with rawl plugs and wooden screws at 300mm centers Main 'T' runners are then suspended from ceiling using GI slotted cleats of size 27x37x25x1.6m fixed to ceiling with 8mm dia and 45mm long dashfasteners, 4mm Gl adjustable rods with galvanised butterfly level clips of size 85x30x0.8mm spaced at max 1200mm centre to centre along main 'T' and not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall, then 1200mm long cross 'T' is interlocked between the main 'T' at 600mm center to center to form a grid of 1200x600mm and then secondary cross 'T' of length 600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross tees at the ends having length more than 600mm are to be supported independently. Finally white coloured Gyproc 8mm thick Dew Drop/Granular tiles of size 595x595mm having foil on backside & PVC paper on front side wrapped around edges to be placedin grid complete all as specified and directed. |
| 40 | M&L for Concrete bed to drain pipes 150mm bore including packing under, and haunching against the sides of pipes complete surrounding after they are laid and tested, in cement concrete 1:4:8 type D2 complete all as specified and directed. |
| 41 | S&F , for 150 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 42 | S&F , for 150 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, Fixed to wall, complete all as specified and directed |
| 43 | S & F 150 mm bore PVC Bends (SWR) complete all as specified and directed. |
| 44 | Drilling & development of borewell of size 300 mm dia by direct rotary method generally in accordance to IS 2800-1979 (revised & amended) in all kind of soil strata including electric logging keeping sufficient space for pea gravel packing including disposal of surplus soil within 100 mtr. well ramming & stabilization of materials & transportation of drilling rig & other T &P to site complete all specified & directed upto 12 m depth suitable for EWR pipes of dia as catered in this work complete all as specified and directed. |
| 45 | Supply , assembly incl jointing, lowering and fixing PVC pipe 200 mm dia including fittings and fixtures complete all as specified and directed. |
| 46 | Supply , assembly incl jointing, lowering and fling slotted PVC pipe casing 200 mm dia incl fittings and fixtures complete all as specified and directed. |
| 47 | Providing and fixing nylon filter mesh around slotted PVC casing/strainer pipe including binding with GI/SS wire complete all as specified and directed. |
| 48 | S&F of PVC well cap of 200 mm dia of pipe at the top of casing pipe of bore well with locking arrangement complete all as specified and directed. |
| 49 | S&F of PVC bail plug of 200 mm dia of pipe at the top of casing pipe of bore well with fixing arrangement complete all as specified and directed. |
| 50 | Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc, wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 51 | Supply only for chainlink fencing of MS galvanised wire any type or size complete all as specified and directed. |
| 52 | Fixing only chainlink fencing including line wires, any mesh, size and type to any type of standards, rails,straining bolts,etc including provision of binding wire complete all as specified and directed. |
| 53 | M&L, Cement concrete type C-2 1:3:6 using 40 mm graded crushed stone aggregate in surface channels and drains etc including necessary formwork. complete all as specified and directed. |
| 54 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends complete all as specified and directed. |
| 55 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft/loose Soil complete all as specified and directed. |
| 56 | Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 57 | M&L 75 mm thick plain cement concrete type B-2 1:4:8 (using 40 mm graded aggregate) as in floor, complete all as specified and directed. |
| 58 | Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 Grade, complete all as specified and directed. |
| 59 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in roof padding, lintels upto 1.5 m span, coping fillets, bed plates, plinth courses, seismic bands and the like finished fair and even including necessary formwork complete all as specified and directed. |
| 60 | Demolition of cement concrete (Unreinforced) in ground floor and pavings n exc 15cm thick ness (below or above ground level) complete all as specified and directed. |
| 61 | M&L 75 mm thick, PCC 1:3:6 (Nominal Mix), type C-2 (using 20mm graded crushed stone aggregates) as in plinth protection finished even and smooth without using extra cement, complete all as specified and directed Please Enable Macros to View BoQ information |