| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/ eaves board fixed with selp tapping screw complete all as specified and directed. |
| 3 | S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/eaves board fixed with selp tapping screw complete all as specified and directed. |
| 4 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 5 | M&L Brick work using Fly Ash bricks with sub class 'B' bricks curved on plan with mean radius not exc 6m with bricks roughly cut to radius or bricks with wedge shaped joints built in cement mortar 1:6 complete all as specified and directed. |
| 6 | M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan and any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed. |
| 7 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 8 | M&L for 15 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work mixed with water proofing compound in 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. (Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'). |
| 9 | Supply only Liquid water proofing compound all as specified and directed. |
| 10 | M&L 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats of cement based wall putty 1 mm each to wall surface complete all as specified and directed. |
| 12 | M & L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm).Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat long life 10 all as specified and directed. |
| 13 | M & L for preparing new Plastered surfaces of walls and applying two coat of cement base paint on surface of wal all as specified and directed. |
| 14 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and removal off the site. |
| 15 | Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for as directed. |
| 16 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 17 | M&L of coloured Non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floor etc set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match as in floor complete all as specified and as directed. |
| 18 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18Sqm but n. exc. 0.38 Sqm, vertical surfaces, in skirting etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match as in floor complete all as specified and directed. |
| 19 | M&L for 10mm thick rendering in CM (1:4) as backing layer in vertical surfaces of skirting dados repairs to steps complete all as specified and directed. |
| 20 | M&L for glazed coloured ceramic tiles (450x350x7mm thick) on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match over 15mm thick rendering in CM(1:4) all as specified and directed by Engr-in-charge. |
| 21 | M&L for 100 mm thick cement concrete type (1:4:8) D-2 (using 40mm graded crushed stone aggregate) as in sub base finished even and fair |
| 22 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified. |
| 23 | M&L for 75 mm thick cement concrete type (1:4:8) D-2 (using 40mm graded crushed stone aggregate) as in sub base finished even and fair |
| 24 | M & L prepolished coloured chequered cement concrete tiles 30cm x30 cm x25 mm thick confirming to IS - 13081, 1993 with grey cement and pigment set, jointed and pointed in neat cement slurry over and including 20mm thick screed bed in cement morter 1:6 complete all as specified. |
| 25 | M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in coping/ benching for man holes including necessary use and waste of formwork complete all as specified. |
| 26 | Dismantling wrought iron or mild steel work of any description complete all as specified and removal off the site. |
| 27 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified. |
| 28 | ditto all as per item No 32 above but beyond 1.5m or part thereof in depth beyond the first 1.50m complete all as specified. |
| 29 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified. |
| 30 | Removing excavated soils exceeding 250 M but not exceeding 500 M and depositing where directed. |
| 31 | Demolition of cement concrete (reinforced) reinforcement cut as required to facilitate demolition) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and removal off the site. |
| 32 | M&L for Precast cement concrete 1:1.5:3 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. |
| 33 | Demolition of Reinforced cement concrete of roofs,floors(other than ground floors), beams, staircase, landings, chajjas and similar suspended work |
| 34 | M&L for Providing, cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directedNote - (i) The rates include for use of formwork (straight or curved). (ii) Reinforcement shall be measured and paid separately. |
| 35 | S&F 20mm thick of Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 36 | M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Note :- (i) Rates include for grinding and polishing. |
| 37 | Demolition of Stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. |
| 38 | M & L for precast concrete type B0 1:2:4 (12.5 mm graded aggregate) louvers and jallies / jafri, 25 mm thick (measured solid) including all moulding complete all as specified and directed. |
| 39 | M&L for mild steel TMT bars 6mm to 8mm dia cut to length , bent to shape required, including cranking, bending and binding with MS wire, not less than 0.9 mm dia or securing with clip complete all as specified. |
| 40 | M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde -E-165) complete all as specified. |
| 41 | Cleaning of blocked sewage line 150mm bore by rodding with using sectional sewer rod / flexible sewer rod /steel rod or split bamboo stick throughly from both sides between adjacent manholes / inspection chamber to manholes of any depth and size including well flushing with water till clear flow of sewage line is observed including taking out sludge & other foreign particles from manhole & pipe lines and buried in earth pits and spreading of bleaching powder @ 1kg/sqm over the sludge before filling of earth in layer of 30 cm complete all as specified and to the entire satisfaction complete all as specified. |
| 42 | All as per ser item No 41 above but for sewage line of 100/110mm bore.Notes for Ser item No 42(i) Length of manhole to manholes shall be measured in these item.(ii) Cleaning of sewage line to be started from down stream side, in this operation some pipe line will be cleaned automatically and need not to be cleaned by rodding and the same shall not be measured for payment.(iii) The unit rate of the item shall be deemed to include the removal of sludge / waste water accumulated in manhole / inspection chamber due to cleaning of drain by rodding. (iv) Water required for cleaning the sewage line are the responsibility of the contractor and no extra payment will be made in this regard.(v) Cost of bleaching powder and lime shall deemed to be included in unit rate. |
| 43 | Cleaning of septic tank, soakage well of any size by removing of sludge from inside the septic tank and removing to a distance exc. 250m but not exc. 500m and buried the same in to earth pits including excavation of earth pits of required size & depth, depositing & spreading of sludge, returning in filling earth over sludge with bleaching powder @ 1 Kg/sqm and removal of surplus soil to a distance not exc. 50m all complete as specified.NOTE : Earth to be filled over the pit over bamboo matting after sufficient absorption of liquid for a period of 48 hours and spreading of bleaching powder over the sludge before earth filling as directed by the Engr-in-Charge. Cost of bamboo matting, spreading of bleaching powder and excavating the earth pit and filling earth etc shall be included in the unit rate as quoted and size of pit shall be made accordingly as directed by Engr-in-Charge. The measurement of sludge shall be taken as per size of earth pit with actual depth of sludge deposited in the earth pit after initial settlement of 48 hours. |
| 44 | Cleaning of blocked man holes upto 60cm depth by removing of sludge from inside and removing to a distance exc 200m but n. exc. 500m and burried the same into earth pits including excavation of earth pits of required size & depth, depositing & spreading of sludge, returning in filling earth over sludge and removal of surplus soil to a distance not exc. 50m all complete as specified. |
| 45 | All as per item No 45 above but exc 0.60 Metre but n.exc. 1.50 Metre in deep complete all as specified. |
| 46 | M&L for cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required, internal dia of pipe 100/110mm complete all as specified. |
| 47 | Taking down eaves gutter ,rain water pipes ,CI/PVC/AC soil pipe with fittings from wall, treches of any description including fittings. |
| 48 | S & F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls. |
| 49 | S&F 110mm dia PVC bends of any radius acess door. |
| 50 | S&F 110mm dia PVC (SWR) branch piece single (single 'Y'/T) equal or unequal with acess door. |
| 51 | S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls. |
| 52 | S & F 75 mm bore PVC (SWR) bends of any radius. |
| 53 | S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door. |
| 54 | S&F in repair CI Nahani trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1(diameter of outlet 100mm) complete all as specified. |
| 55 | Dismantling water tanks and removing to store of capacity exc 500 & n.exc 1000 ltrs. |
| 56 | S & F 1000 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed. |
| 57 | S&F in repair 20 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut. (Make : PRAYAG). |
| 58 | S&F 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed. (Make : ESSCO/Marc/Zoloto). |
| 59 | Taking up or down GI 15mm bore pipe and connection including cleaning for refixing or removal from site as directed. |
| 60 | Taking up or down GI 20mm steel tubing and connections incl cleaning for refixing or removal to store. |
| 61 | S&F 15mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed. |
| 62 | S&F 20mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed. |
| 63 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channels/drain including forming fair finished to drain channel complete all as specified. |
| 64 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified. |
| 65 | M&L for 75mm thick PCC (1:3:6) type C-2 with using 40mm graded stone aggregates as in plinth protection laid in panels and finished even and fair including necessary form work complete all as specified and as directed. |
| 66 | S & F Structural steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde -E-250 quality- A) Add to any of the foregoing items if structural steel is painted one shop coat of zincchromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication all as specified and directed. |
| 67 | S&F Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 68 | S& F in repair for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 69 | S& F in repair for 150 mm dia PVC (SWRPVC (SWR) gully trap 125/110 mm, setting and jointing with solventcement complete all as specified and as directed. |
| 70 | S&F in repair Vitreous china wash down water closet pan (pedesatal pattern) (EWC) white including plastic water closet seat cover closed pattern with flat bottom, and cover and mild steel chromium plated hinging divice etc complete.Make: Prayag model GLECY No 4022 for pan and 518 for seat cover or equivalent as in the list of makes. |
| 71 | S&F in repair Water Closet (squatt pattern) of vitruous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cirstern and flush pipe) including connection to trap and flushing pipe anti syphon pipe etc complete including trap set in and incl concrete complete all as specifiedMake: Prayag model No 4054 or equivalent as in the list of makes. |
| 72 | S&F in repairs of PVC low level flushing cistern, 10 ltr capacity, syphonic action type white body with inlet ball valve, float , handle, bracket, long flush pipe of PVC to suit flushing cistern ( long bend) etc complete & connecting to WC (Make : Sleek of Hindware, Slimline of Parryware or equivalent of Cera) |
| 73 | S&F in repar vitreous China Urinal, Half stall type, white (including flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.Make: Prayag model No 4998 or equivalent as in the list of makes. |
| 74 | S&F PVC connections 15 mm size with PTMT nuts of length 600 mm. |
| 75 | Supply and fix in repair CP Health Faucet of premium quality and PVC telephonic flexible tube fixed to 15mm bore pipe.Make : Jaquar Cat No. ALD-CHR-587 or techno commercially equivalent in Nycer/Cera/Kohler/Pearl/ROCA/Plumber/Essco |
| 76 | S&F in repair 15 mm bore two way bip taps CP with flage complete all as specified and direcrted. Make- ESSCO Cat part DLX-512ANKN or techno commercially equivalent in Cera/Nycer/ROCA/Plumber/Jaquar |
| 77 | S&F in repairs vitreous china wash basin, white, flat back, size 550x400m excluding taps, waste , including chain & plug & porcelain stopper ,brackets, cutting for pinning in ends of bracketes or erecting stand and fixing and supply and waste pipe complete all as specified and directed |
| 78 | S&F 15 mm fancy type swan neck pillar taps, cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore. (Make : ESSCO/Marc/Cera). |
| 79 | S&F in repairs angle valve, fancy type chromium plated, brass, 15mm bore complete all as specified and directed. Make- ESSCO Cat part MQT-526NKN or techno commercially equivalent in Cera/Nycer/ROCA/Plumber/Jaquar. Please Enable Macros to View BoQ information |