| 1 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep for taking out/ laying of pipe and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread any type of soil complete all as specified and directed by Engr-in-Charge. |
| 3 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 4 | Taking up or down old GI/MS/CI/DI/PPR tubing of 80/90 mm bore dia and connections including cleaning for refixng (serviceable) or removal to store complete all as specified and directed. (Excavation and earthwork measured and paid separately). |
| 5 | All as per ser item No 04 (here-in- before) above but bore of Pipe 50/63 mm dia pipe |
| 6 | All as per ser item No 04 (here-in- before) above but bore of Pipe 40 mm dia pipe |
| 7 | All as per ser item No 04 (here-in- before) above but bore of Pipe 32/25 mm dia pipe |
| 8 | Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-16) including PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 90 mm including all fittings complete all as specified and directed by Engr-in-Charge. |
| 9 | All as per ser item No 08 (here-in-before) but size of PPR Pipe 63 mm |
| 10 | All as per ser item No 08 (here-in-before) but size of PPR Pipe 50 mm |
| 11 | All as per ser item No 08 (here-in-before) but size of PPR Pipe 40 mm |
| 12 | All as per ser item No 08 (here-in-before) but size of PPR Pipe 32 mm |
| 13 | All as per ser item No 08 (here-in-before) but size of PPR Pipe 25 mm |
| 14 | M&L for 50 mm bore gate valve cast bronze alloy screwed down high pressure with clutch handle screwed both ends for iron pipe including taking out of old gate valve complete all as specified and directed. |
| 15 | All as per ser item No 14 (here-in- before) above but size 25 mm bore |
| 16 | Supply & fixed in repairs PP-R Gate valves (brass insert) 63 mm outer dia of pipe complete all as specified and directed. |
| 17 | All as per ser item No 16 (here-in-before) but size of PPR gate valve 50 mm |
| 18 | All as per ser item No 16 (here-in-before) but size of PPR gate valve 40 mm |
| 19 | All as per ser item No 16 (here-in-before) but size of PPR gate valve 32 mm |
| 20 | All as per ser item No 16 (here-in-before) but size of PPR gate valve 25 mm |
| 21 | M&L for cutting of all burned winding of motor upto 7.5-10 HP, cleaning of all parts and rewinding with new super enameled winding wire copper of suitable /existing gauge including all insulating materials such as PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and applying insulating varnish and heating in heat chamber at appropriate temperature complete all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fixing in repair fully automatic star delta starter for submersible pump set of rating upto 10 HP, 415 volts, 50 Hz having with sheet metal encloser and relay range 3 phase, 15 to 23 Amps rating alongwith single phase preventer, contactor, panel mounting type complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for run lead joint for CI pipes or specials suitable for 100 mm bore pipes incl spun yarn or any other consumable required at site including cleaning of old complete all as specified and directed by Engr-in-Charge. |
| 24 | All as per ser item No 23 (here-in- before) but size of pipe 80 pipe mm bore |
| 25 | Material & labour for repairing of 80 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing comeplete all as specified and directed by Engr-in-Charge. |
| 26 | Material & labour for repairing of 100 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing comeplete all as specified and directed by Engr-in-Charge. |
| 27 | Material and labour for repairing of leakage of GI tube size from 20 mm bore to 25 mm bore dia at any location and any position by cutting /threading /jointing and including earth work etc incl GI fittings such as tee /socket/ elbow/reducer /nipple or as site requirement complete all as specified and directed. |
| 28 | Material and labour for repairing of leakage of GI tube size from 32 mm bore to 50 mm bore dia at any location and any position by cutting /threading /jointing and including earth work etc incl GI fittings such as tee /socket/ elbow/reducer /nipple or as site requirement complete all as specified and directed. |
| 29 | Material and labour for construction of valve pit chamber of internal dimension 90 x 90 x 90 cm with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8), type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 5 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/ loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete including dismantling of old all as specified and and directed. |
| 30 | All as per ser item No 29 here-in-before but of size of valve chamber 60 x 60 x 60 cm complete all as specified and directed at site by Engr-in-Charge. |
| 31 | Supply only Calcium Hypo Chlorine (55-65%) Chlorine content calcium based granular disinfectant (45 kg sealed drum ) for water treatment, much more stable than Chorine Gas, and stronger than bleaching powder & sodium hypochoride complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for cleaning of internal surface of 10000 Gallons capacity Steel PS OH tank installed at height of 40' to 50' by scraping with brush, rubbing down scales, dirt, sludge etc and washing with clear using bleaching powder/caustic soda and taking all rubbish from the tank and removing the same to a distance not exc 50 mtr and applying filling compound to fill joint gap internally including the writing of date of cleaning complete all as specified and directed. Please Enable Macros to View BoQ information |
| 33 | M&L for cleaning of internal surface of 10000 Gallons capacity Steel PS OH tank installed at height of 40' to 50' by scraping with brush, rubbing down scales, dirt, sludge etc and washing with clear using bleaching powder/caustic soda and taking all rubbish from the tank and removing the same to a distance not exc 50 mtr and applying filling compound to fill joint gap internally including the writing of date of cleaning complete all as specified and directed. Please Enable Macros to View BoQ information |