| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR/REPLACEMENT OF EXTERNAL LIGHTING SYSTEM INCLUDING SECURITY LIGHT, FLOOD LIGHTS, TIMER CONTROLLER PANELS AND ALLIED MISCELLANEOUS WORKS AT NAA INCLUDING HOLESWAR AREA UNDER GE(N)TEZPUR. Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8280/E8) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Supply & Fixing in replacement PVC insulated weather proof sheated alluminium cable 1.5 Sqmm 3 core complete all as specified and directed. |
| 3 | Supply and Fixing in replacement energy saving & environmental friendly long life pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source with secondary optics & exclusively designed polycarbonate cover alongwith electronic driver suitable for 32/40 mm dia bracket size of capacity 45 W LED complete all as specified and directed |
| 4 | Supply and Fixing in replacement energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source with secondary optics & exclusively designed polycarbonate cover alongwith electronic driver suitable for 32/40 mm dia bracket size of rating 60 W LED complete all as specified and directed. |
| 5 | Supply and Fixing in replacement energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 flood luminaire with high power LEDs as light source with secondary optics & exclusively designed polycarbonate cover along with electronic driver of rating 100W LED Flood light complete all as specified and directed. |
| 6 | Supply and Fixing in replacement energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 flood luminaire with high power LEDs as light source with secondary optics & exclusively designed polycarbonate cover along with electronic driver of rating 150W LED Flood light complete all as specified and directed. |
| 7 | Supply and fixing in replacement of LED Post Top Lantern of ,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source of 15 Watt LED including fixing on 40mm dia grouted in post complete with and including angle iron cage as per existing shape and size of piller to protect the any damage by monkeys complete all as specified and directed. |
| 8 | Supply & fixing in replacemet Erecting Steel tubular Swaged Pole Type 410-SP-31 (9.0 mtrs long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous paint from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Paint over a coat of Primer (Externally from Top of Coping), including necessary earth work, excavation, PCC 1:3:6 using 40mm graded sone aggregate for foundation and coping with PCC 1:2:4 using 20mm stone aggregate and smooth finish complete all as specified and as directed. |
| 9 | M & L in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long icluding necessary fixing arrangement using MS clamps,nuts & bolts complete all as specified and directed. |
| 10 | S & F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed |
| 11 | M & L Alluminium strip 25 x 3.15 mm with procelain saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 12 | S & F in repairs Galvanised iron strip 32 x 6mm buried in ground or fixed to Roof, Walls by using appropriate insulating Boxes with screws complete all as specified and directed. |
| 13 | S&F in repair Tri colour LED Column light 50 W capacity of 4m height with die-cast aluminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage & IP65 protection with Tricolor and tratic white output switch fixed on PCC block 1:4:8 type D2 40mm grade. Make Bajaj model No BLSLC 50W LED TRI 4M or of equivalent make all complete as specified and directed. Note: PCC shall be measured and paid seperately under relevent item. |
| 14 | S&F in repair LED light column 40 W capacity of 1.5m height 3000K with die-cast aluminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage & IP65 protection with Tricolor and tratic white output switch fixed on PCC block 1:4:8 type D2 40mm grade.Make Bajaj model No Bajaj Kolux 40W 30K 1.5M 165 BN or of equivalent make all complete as specified and directed. Note: PCC shall be measured and paid seperately under relevent item. |
| 15 | Material and Labour for path light LED bollard 10W in cylindrical shape with opal acrylic diffuser and IP 65 & IK-10 protection with silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landscape enironment fixed on PCC block 1:4:8 type D2 40mm grade all as specified and directed.Note: PCC shall be measured and paid seperately under relevent item. |
| 16 | M&L in replacement street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape , fixing for LT steel poles with flat iron clamps 40mm x 6 mm – 02 sets including nuts, bolts and washers including one coat of aluminium pait over acoat of red oxide primer including taking down of old unserviceable complete all as specified. |
| 17 | M&L in replacement street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape , fixing for RCC LT poles with flat iron clamps 40mm x 6 mm – 02 sets including nuts, bolts and washers including one coat of aluminium pait over acoat of red oxide primer including taking down of old unserviceable complete all as specified. |
| 18 | Material and labour for replacement of junction boxes with new Thermoplastic Cable Junction Boxes IP66/67 \\"weather proof\\" , for outdoor installation with knockouts for cable entry with terminals suitable for 10-16sqmm cable off Size 155 X 210 X 92 mm incl busbar fixed in repairs and including Necessary civil works and connecting all incoming and outgoing wires with AL lugs of appropiate sizes and complete all as specified and directed by Engr-in-Charge. |
| 19 | Material & Labour for fabrication of Sheet metal enclosure, powder coated of Timelite Distribution Boards for automatic Switching of street lights internally pre wired by using suitable copper lugs including fixing with MS Clamp 40X5 mm to steel/RCC poles incl connection consisting of the following: (i) Digital control Astronomical type time switch 24 hrs operation 230 Volts (ii)3 pole contactor 40Amps (iii) MCB FP 32 Amps |
| 20 | Supply and fixing as in replacement of Time Switch, Digital control,Astronomical type suitable for daily operation in 230 volts AC supply complete all as specified and directed. |
| 21 | Supply and fixing as in replacement of three pole power contactor with control relay with AC Coil suitable for operation in 415 volts AC supplywith 230 volt relay coil and current rating 40Amps complete all as specified and directed. . |
| 22 | Supply and fixing as in replacement of MCB FP 32A 'C' Type for operation in 230/415 volts AC supply complete all as specified and directed. . |
| 23 | M&L for earthing complete with galvanised perforated steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge of the pipe not less than 1.25 metres below ground level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 2 of SSR Part I connected to earth test point all as specified or indicated and connected earth work, in soft/loose soil, removing soil upto 50m, refilling agricultural soil if sandy soil, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI light grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways and with handle made out of 20mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt at 2.5Mtr depth and testing on completion, complete all as specified and directed. |
| 24 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 25 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 26 | Supply & fixing in replacement of PVC conduite medium grade not less than 19/20mm dia fixed with RCC/steel tubular pole clamp or by any other means complete all as specified and directed. |
| 27 | M&L for 40 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed. |
| 28 | M &L for Elastomer sheathed flat twin core cable of size 10sqmm all complete as specified and directed. |
| 29 | M&L for PVC self illuminating adhesive strips of different colours (red/yellow) for street light pole all complete as specified and directed. |
| 30 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations etc, or for shafts, wells, cesspits, man holes, pier holes etc not exc 10 sq m on plan and getting out in soft / loose soil complete all as specified and directed. |
| 31 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed. |
| 32 | Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 33 | Material and labour for sand cushioning for cable protection using clean dry sand complete all as specified and directed. |
| 34 | Supply and laying in trenches brick common burnt clay building brick, sub class 'B' designated- 75 with width equal to length of brick for cable protection including demolition of unserviceable existing complete all as specified and directed. |
| 35 | M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 mm bore complete all as specified and directed. |
| 36 | M&L for PCC (1:4:8) type D2 using 40 mm graded aggregate as in foundations of Poles and filling of mass concrete including demolition of unserviceable existing pcc work complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |