| 1 | Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 2 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 3 | Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed. |
| 4 | M & L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. |
| 5 | S & F Sub-Class ‘B’ Brick, well burnt, laid breadthwise along the length of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. |
| 6 | Supply & laying LT XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured electric power cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, laid in trenches/ surface of Wall/in GI Pipe along with Pole for connection to OH Lines including cable glands/ mild steel flat iron clamps/lugs for termination etc as required and testing for following sizes, complete all as specified and as directed.Note : Earthworks, Sand Cushioning, Bricks, etc. will be measured and paid under appropriate Items. |
| 7 | 2 Core x 10 Sqmm |
| 8 | 4 core x 10 Sqmm |
| 9 | 4 core x 16 Sqmm |
| 10 | 3.5 core x 25 sqmm |
| 11 | 3.5 core x 50 sqmm |
| 12 | 3.5 core x 70 sqmm |
| 13 | Relaying of serviceable LT cable retrieved from taking down in trenches or fixing with walls/poles, passing through Pipes etc complete all as specified and directed by Engr-In-Charge |
| 14 | Relaying of serviceable Bricks retrieved from taking down in trenches for cable protection over sand cushioning complete all as specified and directed by Engr-In-Charge |
| 15 | Taking down/out unserviceable LT Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laid in trenches or fixing with Walls/Poles, segreating serviceable Pipes, Cables etc and keep serviceable cable and Bricks in safe custody for reuse, complete all as specified and as directed.Note : Earthwork will be measured and paid under appropriate Items. |
| 16 | S & F LED street light 60W made up off pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with electronic driver suitable for 60 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements ncluding taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge.Note :- Housing of street light fitting shall be suitable for 40 to 50 mm dia of bracket. |
| 17 | S & F LED street light 50W made up of pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with electronic driver suitable for 50 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements ncluding taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge.Note :- Housing of street light fitting shall be suitable for 40 to 50 mm dia of bracket. |
| 18 | S & F LED flood light 100W made up of pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with electronic driver suitable for 100 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge. |
| 19 | S & F LED flood light 150W made up of pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with electronic driver suitable for 150 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge. |
| 20 | S & F LED flood light 200W made up of pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with electronic driver suitable for 200 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge. |
| 21 | All as per item No 14 above but of 300W Complete all as specified and as directed by Engr-In-Charge. |
| 22 | S & F in replacement of LED flood light 50W made up of pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with battery backup, electronic Charger, adaptor, carrying handle and stand suitable for 50 watts light fitting lumen efficacy of light fitting shall be not less than 100 lm/W. complete all as specified and directed by Engr-in-charge. |
| 23 | M & L street light fittings bracket made out from GI pipe 32/40 mm bore, light grade 1.00 meter long bent to required shape and fixing to poles walls etc including supply and fixing of MS clamp nuts, bolts as required duly painted with two coat of aluminum paint over a coat of red oxide primer including taking out old one complete all as specified and directed by Engr-In-Charge. (Note : The cost of painting shall be deemed to be included in the unit rate quoted against this item) |
| 24 | S & F post top lantern LED 18W made up of pressure die cast aluminium housing and LEDs as a light source prewired with electronic holder B22 with suitable lamp for 18 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge. |
| 25 | S & F LED Land Scape minimum 9W made up of pressure die cast aluminium housing and LEDs as a light source prewired with electronic holder B22 suitable for minimum of capacity 9 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with pole of height upto 1 mtr including mounting arrangements on floor/ Earth using PCC of appropriate ration as required including 9 watt lamp coloure as decided at site including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge. |
| 26 | S & F Junction Box for Street Lights of size minimum 205x255x112 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected , door pasted with rubber gasket, water tight IP 65 protection with teriminal box for three phase 4 wire system of rating min 32 Amps suitable to terminate LT Cable of size upto 25 sqmm.with option to mount one no MCB SP 06 amps including cable glands at both incoming and outgoing side mounted on security light pole with suitable bracket nuts, bolts including removal of exiting unsv all as specified and directed. Junction Box. |
| 27 | Taking down unservicable high mast light fittings of any height/watt/make, repair of gear box, pulley and rope mechanism including greasing, replacement of the unsv parts unsv/burnt cable, terminals etc as required at site, after repairing fixing at same position complete all as specified and directed.Note:- (a) Spare part wherever required will be measured and paid under appropriate Item(s) as 'supply only'.(b) Labour and T&P required for replacement of unserviceable Parts, general servicing, greasing and minor items like clamps, lugs, terminals etc are deemed to be included in the quoted unit rate. Please Enable Macros to View BoQ information |
| 28 | Taking down unservicable high mast light fittings of any height/watt/make, repair of gear box, pulley and rope mechanism including greasing, replacement of the unsv parts unsv/burnt cable, terminals etc as required at site, after repairing fixing at same position complete all as specified and directed.Note:- (a) Spare part wherever required will be measured and paid under appropriate Item(s) as 'supply only'.(b) Labour and T&P required for replacement of unserviceable Parts, general servicing, greasing and minor items like clamps, lugs, terminals etc are deemed to be included in the quoted unit rate. Please Enable Macros to View BoQ information |