| 1 | Dismantling and taking up or down old Unserviceable service cable amd LT UG cable of any size complete all as specified and directed |
| 2 | Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional area :-10 Sqmm 2 Core |
| 3 | 25 Sqmm 3.5 Core |
| 4 | 35 Sqmm 3.5 Core |
| 5 | 50 Sqmm 3.5 Core |
| 6 | 70 Sqmm 3.5 Core |
| 7 | 95 Sqmm 3.5 core |
| 8 | 120 Sqmm 3.5 core |
| 9 | Excavation in trenches, n exc 1.5m wide and n. exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for hard/dense soil. |
| 10 | Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for hard/dense soil. |
| 11 | Removing excavated material n exc. 50 m and depositing where directed at a layers not exc 25 cm. for hard/dense soil. |
| 12 | S&F Double walled corrugated (DWC) Pipe conforming to IS 14930(Part-II) Pipes of Outer dia 63 mm and innder dia 50mm including taking out old unserviceable pipeall as specified and as directed. |
| 13 | S&F Double walled corrugated (DWC) Pipe conforming to IS 14930(Part-II) Pipes of Outer dia 90 mm and innder dia 76mm including taking out old unserviceable pipeall as specified and as directed. |
| 14 | Supply and fixing in replacement MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 36 KA complete with all accessories all as specified and directed. |
| 15 | Supply and fixing in replacement MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA complete with all accessories all as specified and directed. |
| 16 | Supply and fixing in replacement MCCB 4 Pole, 415 V, 125 Amps with breaking capacity 16 KA complete with all accessories including taking out old unserviceable MCCB all as specified and directed. |
| 17 | Supply and fixing in replacement MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 16 KA complete with all accessories including taking out old unserviceable MCCB all as specified and directed. |
| 18 | Supply and fixing in replacement MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 16 KA complete with all accessories including taking out old unserviceable all as specified and directed. |
| 19 | M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion including dismantling of old unserviceable earthing all as specified and directed.. |
| 20 | M&L for pruning of tree branches which is touches on LT/HT over head conductor. |
| 21 | M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable including taking out old unserviceable pipe complete all as specified. |
| 22 | M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable including taking out old unserviceable pipe complete all as specified. |
| 23 | M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 80 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable including taking out old unserviceable Pipecomplete all as specified. |
| 24 | M&L for locating of electrical fault in Feeder pillar/ LT electric panel/MCB DB/Busbar Chamber/Changeover Switch of any size and repair by using of suitable size of cable lugs/Nut & bolts and make the good disturbed surfaces all as specified and directed by Engr-in-charge. |
| 25 | M & L for Painting of Steel tubler pole up to 9 mtr long by using Two coats of aluminium paint with one coat of red oxide primer.all as directed by Engr - in - charge |
| 26 | Supply and fix LT cable jointing kit for 1100 Volt grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 6 to 16 sqmm 3.5/ 4 Core,Outdoor type all as directed and as specified. |
| 27 | Supply and fix LTcable jointing kit for 1100 Volt grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 25 to 50 sqmm 3.5/ 4 Core,Outdoor type Outdoor type all as directed and as specified. |
| 28 | Supply and fix LT cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 70 to 95 sqmm 3.5/ 4 Core,Outdoor type Outdoor type all as directed and as specified. |
| 29 | Supply and fix LT cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 120 to 185 sqmm 3.5/ 4 Core,Outdoor type Outdoor type all as directed and as specified. |
| 30 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking out old unserviceable street light complete . Make Havells/CG/Bajaj/Phillips |
| 31 | Supply and fix ON Load changeover switch side handle in sheet enclosure 415 V AC 50 Hz of Capacity 63 Amp 4 pole including taking out old unserviceable changeover switch all as directed by Engr- in- charge Make : Havells ,L&T,Legrand and its equivalent |
| 32 | Supply and fix ON Load changeover switch side handle in sheet enclosure 415 V AC 50 Hz of Capacity 100 Amp 4 pole including taking out old unserviceable changeover switch all as directed by Engr- in- charge Make : Havells ,L&T,Legrand and its equivalent |
| 33 | Supply and fix ON Load changeover switch side handle in sheet enclosure 415 V AC 50 Hz of Capacity 160 Amp 4 pole including taking out old unserviceable changeover switch all as directed by Engr- in- charge Make : Havells ,L&T,Legrand and its equivalent |
| 34 | Supply and fix ON Load changeover switch side handle in sheet enclosure 415 V AC 50 Hz of Capacity 250 Amp 4 pole including taking out old unserviceable changeover switch all as directed by Engr- in- charge Make : Havells ,L&T,Legrand and its equivalent |
| 35 | S&F of aluminium lugs of following sizes:- a)10 sq mm |
| 36 | b)16 sq mm |
| 37 | c)25 sq mm |
| 38 | d)35 sq mm |
| 39 | e)50 sq mm |
| 40 | f)70 sq mm |
| 41 | g)95 sq mm |
| 42 | h)120 sq mm Please Enable Macros to View BoQ information |