| 1 | Taking down carefully copper/aluminium point wiring including sunken M S Boxes (Light, Fan, socket or power) complete, (fitting such as switches, ceiling roses, call bell, pendants, regulators, socket etc by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc, complete all as specified and directed. |
| 2 | M&L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLSH unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including Non metalic PVC rigid conduit medium grade with ISI mark of size 20mm dia with all accessories concealed in wall/ceiling /floor/roof etc, including factory made galvanized steel pressed terminal boxes alongwith suitable modular cover plate with frame for fixing modular switches,sockets,fan regulators etc., of suitable modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following One light point controlled by one modular switch.NOTE: Modular switches will be mesured and paid seperately under relavant items. |
| 3 | All as per item No. 2 above but One light point controlled by two, 2 way modular switches. |
| 4 | All as per item No. 2 above but One ceiling fan/Exhaust fan point controlled by one modular switch. |
| 5 | All as per item No. 2 above but One bell point controlled by one modular bell push. |
| 6 | All as per item No. 2 above but One three pin modular socket 5/6 amps outlet on same board. |
| 7 | All as per item No. 2 above but One three pin modular socket 5/6 amps outlet on independent board. |
| 8 | All All as per item No. 2 above but for one socket point 15 Amp with 2.5 sqmm PVC unsheathed FRLS wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly. |
| 9 | All as per item No. 2 above but for one socket point 15 Amp with 4 sq mm PVC unsheathed FRLS wire along with 4 sq mm green colour wire as earth contuinity conductor connected to common earth dolly. |
| 10 | S&F modular switch 1 way 6A, 1 module, 230 Volts all as, complete all specified and directed. |
| 11 | S&F modular switch 2 way 6A, 1 module, 230 Volts, complete all specified and directed. |
| 12 | S&F modular bell push 6A, 1 module, 230 Volts, complete all specified and directed. |
| 13 | S&F modular switch 1 way 16A, 1 module, 230 Volts, complete all specified and directed. |
| 14 | S&F modular socket 6 A- 2/3 pin combined, 230 Volts, 2 modules with ISI mark, complete all specified and directed. |
| 15 | S&F modular socket 6/16 A- 2/3 pin combined, 230 Volts, 2 modules with ISI mark, complete all specified and directed. |
| 16 | M&L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLSH unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including PVC casing & caping with ISI mark of size 20mm dia with all accessories concealed in wall/ceiling /floor/roof etc, with cast iron/pressed steel terminal box of suitable sizes & 1.6 mm thick duly painted inner & outside by anti-corrosive paint, for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover with brass screw, cup washer complete all as specified and directed for the following One light point controlled by one switch. |
| 17 | All as per item No. 16 above but One Ceiling fan point controlled by one switch and regulator. |
| 18 | All as per item No. 16 above but One 5 Amps socket outlet point on same board controlled by one switch. |
| 19 | S/F Switch piano, flush type single pole, one way, 5 Amps, 240 volts, complete all as specified and directed. |
| 20 | S/F for socket outlet 2 in 1, 3 pin, 5A, complete all as specified and directed. |
| 21 | S&F ceiling rose surface bakelite 65 x 50mm with three terminals with ISI mark, complete all as specified and directed. |
| 22 | S&F Bell ding-dong 230 V, single pole, complete all as specified and directed. |
| 23 | S&F in repairs Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings and including white LED bulb, complete all as specified and directed. |
| 24 | Supply, installing, testing and commissioning Indoor type meter panel board of suitable size as per IS, wall mounted, transparent glass to view the meter in the panel,dust and vermin proof, Front openable type IP 54 protection made of 2 mm thick CRCA sheet duly painted internally and externally with powder coating paint and accessories and having proper locking arrangement in front suitable for 440 volts, 50 Hz, system and comprising with and including following accessories for accomodate 08 Nos single/three phase meter ( shock proof & weather proof) and necessary accessories for fixing in wall/floor complete including dismantling, connection of existing meter, including removal of meter and refixing the same in box, complete all as specified and directed. |
| 25 | Supply, install & testing exhaust fan sturdy Engineering plastic 300 mm sweep heavy duty 1400 RPM complete fixed to wall with suitable size bolts, grouted to wall and connecting up including provision of cable from connector to fan with three core flexible cable of size 24/0.2mm with copper conductor from ceiling rose to exhaust fan and taking down old exhaust any type and make, complete all as specified and directed. |
| 26 | Supply, install & testing exhaust fan sturdy Engineering plastic 250 mm sweep heavy duty 1400 RPM complete fixed to wall with suitable size bolts, grouted to wall and connecting up including provision of cable from connector to fan with three core flexible cable of size 24/0.3mm with copper conductor from ceiling rose to exhaust fan and taking down old exhaust any type and make, complete all as specified and directed. |
| 27 | S&F in repair factory made sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 20/25 Amps, complete all as specified and directed. |
| 28 | S&F in repair 20W (1x4') wall/roof mounted LED batten, (warm/cool) as per demand extruded aluminium housing provided for efficient heat dissipation, with necessary wiring, including all required accessories for light fitting with fixing arrangement, complete all as specified and directed. |
| 29 | S&F in repair 10W (1x2') wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation, with necessary wiring, including all required accessories for light fitting with fixing arrangement, complete all as specified and directed. |
| 30 | S&F in repair decorative wall light fixture made of polycarbonate suitable to fix LED bulb of 15W with B-22 base with necessary wiring complete with all fixing arangement, complete all as specified and directed. |
| 31 | S&F in repair 35W Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 rotection and Impact resistance of IK07 with 10KV Built-in Surge Protection Devicecomplete with all fixing arrangement suitable for operating voltage 100 to 270 Volts, complete all as specified and directed. |
| 32 | Taking down serviceable / unserviceable switch fuse unit/MCB DB with MCB etc for necessary repair/replacement and reuse, complete all as specified and directed by Engineer in Charge. |
| 33 | S&F MCB DB TPN 4 way having degree of protection as per IP 43-IK09 with metal door (double door) 415 Volts complete copper bus bar with neutral link with provision for MCB TPN as incomer and MCB TP, SP MCBs as outgoing with blanking plates etc, complete all as specified and directed. |
| 34 | S&F MCB DB SPN 8 way having degree of protection as per IP 43-IK09 with metal door (double door) 230 Volts complete copper bus bar with neutral link with provision for MCB SPN as incomer and MCB SP MCBs as outgoing with blanking plates etc, complete all as specified and directed. |
| 35 | S&F MCB DB SPN 4 way having degree of protection as per IP 43-IK09 with metal door (double door) 230 Volts complete copper bus bar with neutral link with provision for MCB SPN as incomer and MCB SP MCBs as outgoing with blanking plates etc, complete all as specified and directed. |
| 36 | S&F DB VTPN 4 way having degree of protection as per IP 43-IK09 with metal door (double door) 415 Volts complete copper bus bar with neutral link with provision for MCCB TPN as incomer and MCB TP, SP MCBs as outgoing with blanking plates etc, complete all as specified and directed. |
| 37 | S&F MCCB, 4 pole, 63 to 100 Amp with ultimate breaking capacty Icu-16kA at 415 Volts and fixed thermal magnetic release, complete all as specified and directed. |
| 38 | S&F MCB, 3 pole, 32 Amp C curve with ultimate breaking capacty Icu-16kA at 415 Volts, complete all as specified and directed. |
| 39 | S&F MCB, 4 pole, 32 Amp C curve with ultimate breaking capacty Icu-16kA at 415 Volts, complete all as specified and directed. |
| 40 | S&F MCB SPN 6 to 32 Amps 230 Volt, 10 KA, 'C' series, complete all as specified and directed. |
| 41 | S&F MCB SP 6 to 32 Amps 230 Volt, 10 KA, 'C' series, complete all as specified and directed. |
| 42 | Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement, complete all as specified and directed. |
| 43 | M&L for submain wiring complete all as specified with Six runs of 1100 Volts grade 10 sqmm PVC insulated FRLSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking (Phases R-Y-B, Neutral and Earth) in and including non metalic rigid PVC conduit medium grade with ISI mark of suitable size with all accessories as per IS code concealed in wall/ceiling /floor/roof etc,. the earth wire to be connected to common earth dolly complete all as specified and directed by Engineer-in-Charge NOTE:- Six runs of 10 sqmm copper wire and one run of 25mm PVC conduit will be measured as one run. |
| 44 | M&L for submain wiring complete all as specified with three runs of 1100 Volts grade 6 sqmm PVC insulated FRLSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking (Phase, Neutral and Earth) in and including non metalic rigid PVC conduit medium grade with ISI mark of suitable size with all accessories as per IS code concealed in wall/ceiling /floor/roof etc,. the earth wire to be connected to common earth dolly complete all as specified and directed by Engineer-in-Charge NOTE:- Three runs of 6 sqmm copper wire and one run of 25mm PVC conduit will be measured as one run. |
| 45 | M&L for submain wiring complete all as specified with three runs of 1100 Volts grade 4 sqmm PVC insulated FRLSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking (Phase, Neutral and Earth) in and including non metalic rigid PVC conduit medium grade with ISI mark of suitable size with all accessories as per IS code concealed in wall/ceiling /floor/roof etc,. the earth wire to be connected to common earth dolly complete all as specified and directed by Engineer-in-Charge NOTE:- Three runs of 4 sqmm copper wire and one run of 25mm PVC conduit will be measured as one run. |
| 46 | Supply and fixing in repair of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr including 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers, complete all as specified and directed. |
| 47 | S&F in repairs heating element 1.5 KW capacity of appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed.Make:- As per sample. |
| 48 | S&F in repairs heating element 2.0 KW capacity of appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed.Make:- As per sample. |
| 49 | S&F in repairs heating element 3.0 KW capacity of appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed.Make:- As per sample. |
| 50 | S&F in repairs repair thermostat of capacity and rating ISI marked suitable for 15 Ltr/25 Ltr/35 Ltr/50 Ltr capacity storage type water heater (Geyser), complete all as specified and directed. Suitable for Model Calena 25/2018 or other similar models. |
| 51 | S&F in repairs repair Bajaj auto cut thermostat of capacity and rating ISI marked suitable for 15 Ltr/25 Ltr/35 Ltr/50 Ltr capacity storage type water heater (Geyser), complete all as specified and directed. Make: As per sample |
| 52 | S&F in repairs repair Bajaj manual cut thermostat of capacity and rating ISI marked suitable for 15 Ltr/25 Ltr/35 Ltr/50 Ltr capacity storage type water heater (Geyser), complete all as specified and directed. Make: As per sample |
| 53 | S&F in repairs Inner tank made out of copper provided with safety copper valve suitable for 25 Ltr capacity storage type water heater (Geyser), complete all as specified and directed. Suitable for any make/ model. Calena 25/2018 or other similar models. |
| 54 | S&F in repairs Outer made out of mild steel and of appropriate shape/size suitable for 25 Ltr capacity geyser, complete all as specified and directed. Suitable for any Bajaj Calenta 25l / 2018 or other model. |
| 55 | S&F in repairs Inner tank made out of copper provided with safety copper valve suitable for 50 Ltr capacity storage type water heater (Geyser), complete all as specified and directed. Suitable for any make/ model. Calena 25/2018 or other similar models. |
| 56 | S&F in repairs GI fitting Barrel Pieace 1/2\\" pipe 15 mm size appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed. |
| 57 | S&F in repairs GI fitting Barrel Pieace 1/2\\" pipe 25 mm size appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed. |
| 58 | S&F in repairs GI fitting Barrel Pieace 1/2\\" pipe 50 mm size appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed. |
| 59 | S&F in repairs GI pipe 15mm size suitable for storage type water heater (Geyser), complete all as specified and directed. |
| 60 | S&F in repairs GI pipe 20mm size suitable for storage type water heater (Geyser), complete all as specified and directed. |
| 61 | Transportation and fixing/ reconnecting Geyser at new location as decided by Emgr- in- charge, complete all as specified and directed. |
| 62 | M&L for disconnecting and taking down the defective storage type water heater (Geyser) of 15 Ltr/25 Ltr/35 Ltr/50 Ltr capacity and refxing in same position after necessary repairs, complete all as specified and directed. Note :- The repairs and renewal will be measured & paid separately under the respective item of this schedule. |
| 63 | S&F in repairs clamps for fixing/ hanging Geyser appropriate shape suitable for storage type water heater (Geyser) complete all as specified and directed.Make:- As per sample. |
| 64 | S&F in repairs geyser stop valve appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed.Make:- As per sample. |
| 65 | S&F in repairs angle cock appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed.Make:- As per sample. |
| 66 | S&F in repair anchor fastner stud bolt with nut and washer and pin (heavy duty) suitable for fixing of geyser to wall/ angle iron of length upto length 150mm, complete all as specified and directed. |
| 67 | S&F in repairs Geysers 6 ltrs, complete all as specified and directed. |
| 68 | M&L for preparing painting old geyser of 25/35/50 Llitres capacity of any make by removing all dust, dirt, scale, scrapping out old patchy paint and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 69 | S&F in repairs NRV valve 15 mm for geyser of any cap/size, complete all as specified and directed. |
| 70 | S&F in repairs safety valve for geyser of any cap/size, complete all as specified and directed. |
| 71 | S&F in repair electric plug top 20 Amps 240 Volt, complete all as specified and directed. |
| 72 | M & L and fixed in repairs for copper wire connection 1 Sqmm twin core with suitable size Al lugs for Geyser Element. Make: As per sample, complete all as specified and directed. |
| 73 | S&F in repairs/ lay cable in repair insulated screened white PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 4 Sqmm 3 core, complete all as specified and directed. |
| 74 | S&F in repairs Outer made out of mild steel and of appropriate shape/size suitable for 50 Ltr capacity geyser, complete all as specified and directed. Suitable for any make and model. |
| 75 | S&F in repairs glass wool of superior and approved quality, suitable for 25 ltr and 50 ltr capacity storage type water heater (Geyser), complete all as specified and directed. |
| 76 | S&F in repairs indicators with flexible cable cord, pin top by providing new indicator (Green/ Red) assembly with 3 core flexible cord of stranded copper conductor 2.5 Sqmm PVC insulated & over all PVC sheathed 1100 volts grade 2.5 m long duly connected to geyser with and including 3 pin top 15 Amp AC 230 V ISI marked suitable for 25 Ltr/35 Ltr/50 Ltr capacity Geyser, complete all as specified and directed. |
| 77 | S&F in repairs flexible hot water and cold water connection pipe with SS nuts heavy duty ISI marked internally metal coated suitable for fixing from outlet of water pipe to inlet of geyser and from geyser to inlet of hot water pipe and carrying hot water upto 70 degree centrigrate of length 300mm, complete all as specified and directed. |
| 78 | S&F in repairs flexible hot water and cold water connection pipe with SS nuts heavy duty ISI marked internally metal coated suitable for fixing from outlet of water pipe to inlet of geyser and from geyser to inlet of hot water pipe and carrying hot water upto 70 degree centrigrate of length 600mm, complete all as specified and directed. |
| 79 | S&F in repairs flexible hot water and cold water connection pipe with SS nuts heavy duty ISI marked internally metal coated suitable for fixing from outlet of water pipe to inlet of geyser and from geyser to inlet of hot water pipe and carrying hot water upto 70 degree centrigrate of length 900mm, complete all as specified and directed. |
| 80 | S&F in repair anchor fastner stud bolt with nut and washer and pin (heavy duty) suitable for fixing of geyser to wall/ angle iron of length upto length 100mm, complete all as specified and directed. Please Enable Macros to View BoQ information |