| 1 | EXTERNAL WATER SUPPLYExcavating in trenches, n exc 1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil. |
| 2 | Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in soil all as specified and directed. |
| 3 | Removing surplus soil to a distance nexc. 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed. |
| 4 | Supply & Fix 100 mm bore GI water tubing medium grade with all fittings and accessories laid in tranches ISI marked incl taking down old one all as specified and directed. NOTE : Earth work will be paid separately under subsequent item of the Schedule. |
| 5 | Supply & Fix 80 mm bore GI water tubing medium grade with all fittings and accessories laid in tranches ISI marked incl taking down old one all as specified and directed. NOTE : Earth work will be paid separately under subsequent item of the Schedule. |
| 6 | Supply & Fix 50 mm bore GI water tubing medium grade with all fittings and accessories laid in tranches ISI marked incl taking down old one all as specified and directed. NOTE : Earth work will be paid separately under subsequent item of the Schedule. |
| 7 | Supply & Fix 25 mm bore GI water tubing medium grade with all fittings and accessories fixed to walls and ceilings or laid in floors ISI marked incl taking down old one all as specified and directed. |
| 8 | Supply & Fix 20 mm bore GI water tubing medium grade with all fittings and accessories fixed to walls and ceilings or laid in floors ISI marked incl taking down old one all as specified and directed. |
| 9 | M&L for construction of PCC block walling Valve Pit Chamber for 100mm Air Release Valve of size 1.2 mtr x 1.2 mtr x 1.2 mm (internal dimension) with precast cement concrete block of PCC 1:3:6 (PCC 1:3:6) type-C-1 using 20mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40 x 40 x 6 mm mild steel angle iron frame and 3 mm thick MS sheet cover with locking arrangement and 1 No 50 mm size 4 lever lock with key in duplicate , incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specifiled and shown on drawing and as directed by Engr-in-Charge |
| 10 | S&F in repairs of Cast Iron Sluice Valve class PN 1.6 of size 100 mm bore with gun metal spindle both end flanged with all fitting incl taking down old one all as specified and directed. |
| 11 | S&F in repairs of Cast Iron Sluice Valve class PN 1.6 of size 80 mm bore with gun metal spindle both end flanged with all fitting incl taking down old one all as specified and directed. |
| 12 | S&F in repairs of cast Iron Gate Valve of size 50 mm bore with gun metal spindle both end flanged with all fitting incl taking down old one all as specified and directed. |
| 13 | S&F in repairs of cast Iron Gate Valve of size 25 mm bore with gun metal spindle both end flanged with all fitting incl taking down old one all as specified and directed. |
| 14 | S&F in repairs of cast Iron Gate Valve of size 20 mm bore with gun metal spindle both end flanged with all fitting incl taking down old one all as specified and directed. |
| 15 | Supply and fix cast iron Air Release valve with two air outlet, 100mm dia bore all as specified incl taking down old one and as directed by Engineer-in-Charge. |
| 16 | Supply and fix cast iron Air Release valve with two air outlet, 80mm dia bore all as specified incl taking down old one and as directed by Engineer-in-Charge. |
| 17 | Supply and fix cast iron Air Release valve with two air outlet, 50mm dia bore all as specified incl taking down old one and as directed by Engineer-in-Charge. |
| 18 | EXTERNAL ELECTRIFICATIONM & L for Steel Tublar Swaged Poles 9 meter long, complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 incl taking down old unsv pole. Make : ISI marked |
| 19 | M & L for Installing, Testing & Commissioning of LT Panel Board weather proof, powder coated outdoor type double door shutter at front and rear side, made out of CRCA 3.15 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltemeter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etcThe bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron ) incl taking down old unsv panel. |
| 20 | (a) Aluminium bus bar capacity 300 Amps for Phase-R-Y-B-3 Nos & 300 Amps for neutral -1 No(b) MCCB FP 36 KA 200 Amps- 1 Nos (I/C) (c) MCCB FP 36 KA 160 Amps - 3 Nos (d) MCB FP 16KA 63 Amps - 4 Nos (e) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-300 Amps (f) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No 0-500 V (g) Complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder |
| 21 | Supply, install, testing and commissioning of LT Panel board of suitable size , CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door at front and rear side, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable taking down old unsv panel all as directed at site and comprising of the following: Note : Bottom portion of the panel should be at minimum height of .75 Mtr from the ground level. |
| 22 | (a) MCCB 4 pole 400 Amps 50 kA - 01 Nos I/C(b) MCCB 4 pole 160 Amps 25 kA - 02 Nos(c) MCCB 4 pole 100 Amps 25 kA - 01Nos (d) MCCB 4 pole 63 Amps 25 kA - 04Nos (e) MCB TP - 32 Amp -01 Nos(f) Digital timer switch -01 Nos (g) Multifunctional VAF meter, PF meter - 1 No (h) RYB Neon indicating lamp -1 set for each outgoing and incoming (j) MS work incl angle iron frame and PCC work(k) Space for mounting of additional MCB In future. |
| 23 | Supply, install, testing and commissioning of LT Panel board of suitable size the I/C and O/G MCCBs/MCBs Mtrs ,CPRI approved ,outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 250 Amps rating mounted on porcelain insulators .The panels shall be factory made, with double door openings at front and rear side, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable taking down old unsv panel all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of .75 Mtr from the ground level. |
| 24 | (a) MCCB 4 pole 160 Amps 25 kA - 01 Nos(b) MCCB 3 Pole 63 Amp 25 KA - 02(c) MCB 2 pole 25 Amps 10 kA - 6 Nos (d) Street light timer digital type with contctor 3 ph complete for street light(e) Multifunctional VAF meter, PF meter - 1 No (f) RYB Neon indicating lamp -1 set (g) MS work incl angle iron frame and PCC work(h) Space for mounting of additional MCB In future.(j) Internal wiring including copper lugs |
| 25 | Supply, install, testing and commissioning of Bus bar chamber of size .75x.75x.45 Mtrs , CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 100 Amps rating mounted on porcelain insulators having outgoin min 06 Nos .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable taking down old unsv panel all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of .75 Mtr from the ground level. |
| 26 | (a) MCCB 4 pole 63 Amps 16 kA - 01 Nos I/C(b) Aluminium bus bar with provision of 06 nos of outgoing separately for RYB and N (c) Multifunctional VAF meter, PF meter - 1 No (d) RYB Neon indicating lamp -1 set for each outgoing and incoming (e) MS work incl angle iron frame and PCC work(f) Space for mounting of additional MCB In future.(g) Internal wiring including copper lugs |
| 27 | Taking down unsv / damaged Aerial Bunch Cable (ABC) of any size and capacity complete with accessories from 9 mtr Steel Tublar pole all as spcified and directed by Engr-in-Charge at site. |
| 28 | Supply and fix LT overhead lines on 9 meter steel poles with XLPE insulated Aerial Bunch Cable 3-core X 120 sq mm X 1-core X 70 sq mm. |
| 29 | Supply and fix LT overhead lines on 9 meter steel poles with XLPE insulated Aerial Bunch Cable 3-core X 50 sq mm + 1 x 35 sq mm. |
| 30 | M & L for installing, Testing and comissioning of Servo Voltage stabilizer for automatic operation,three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 250 KVA taking down old unsv cable. |
| 31 | Taking down unsv / damaged Street lights of any size and capacity complete with accessories from 9 mtr Steel Tublar pole all as spcified and directed. |
| 32 | Supply and fix LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete taking down old unsv cable. |
| 33 | Supply and fixing LED Solar street light fitting 24 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete taking down old unsv cable. |
| 34 | Taking down unsv / damaged and Supply & fix Pole mounted junction box / cut-out box/fuse box for road/street lighting for LED based lighting system including MCB SP 6 amps 01 Nos , 02 Nos busbar aluminium mounted on pole by means of MS clamps etc . |
| 35 | M&L in repair of Earthing for panel and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 25 x 4mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009 taking down old unsv cable NOTE : If the desired earth resistence is not found , earthing shall be re-done by the Contractor at No Extra Cost paid by the Dept. |
| 36 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core taking down old unsv cable, |
| 37 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core taking down old unsv cable. |
| 38 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core taking down old unsv cable. |
| 39 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core taking down old unsv cable. |
| 40 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core taking down old unsv cable. |
| 41 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core taking down old unsv cable |
| 42 | S&F of Bus bar chamber with door type of size 400 x 380 x 190 mm made out of MS sheet 3mm thick with Copper bus bar three phase & neutral each 320 x 20 x 6 mm of size fixed on insulators and fixing on steel pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles, glands and making good the disturbed surfaces incl water proof PVC sticker like danger mark all as required at site taking down old unsv cable |
| 43 | M&L for High Galvanized Mast Light upto the height of 20 meter and suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike, suitable size of LT Panel ,and all its accessories including RCC foundationand its accessories with following techincal specification :- |
| 44 | (a) MAST STRUCTURE :- The high Mast shall be of continuously tapered, polygonal cross section polygon type (Minimum 16- Sides) of 16 Mtrs. in height presenting good visual appearance and shall be based on proven design to given assured performance, reliability and service. The Mast shall have an approximate top diameter of say 150 mm to 200 mm and bottom diameter of 350 mm to 450 mm, The weight of the Mast shall not exceed more than 1600 kgs, excluding weight of Luminaire, to maintain good elasticity of slender structure. |
| 45 | (b) MAST CONSTRUCTION :- The Mast shall be fabricated from special steel plates of BS EN 10025 grade, cut and folded to form polygonal section and shall be telescopically jointed and fillet welded. The welding shall be in accordance with BS: 5135. The procedural weld geometry and the workmanship shall be exhaustively tested by the radiography on the completed welded and certificates submitted. The Mast shall be delivered in only 2 sections without any circumferential welding at site, which shall be joined together by slip-stressed-fit method. The joining shall be with stressing equipment, thus forming the sleeve joint. No site welding or bolted the joint will be accepted. The overlap distance shall have full penetration of longitudinal welds. The base plate of the mast shall be at least 25 mm. thick. An adequate door opening min 1400mm x 300mm shall be provided at base of each mast such as to permit clear access to equipment like winches, cable pug and socket, etc. The opening shall be complete with a close fitting vandal resistant, weather-proof door provided with a heavy duty lock. For metal protection of the Mast, the entire fabricated Mast shall be hot dip galvanised internally and externally, having minimum average thickness of 65 microns. |
| 46 | (c) DYNAMIC LOADING :- The Mast structure shall be designed for an assumed maximum reaction arising from the maximum wind speed at Mendhar and measured at a height of 10 Mtrs. above ground level . The design life of the Mast shall be min. 25 years. Wind excited oscillation shall be damped by the method of construction and adequate allowance made for the related stresses. The offered High Mast shall be a tested design. |
| 47 | (d) FOUNDATION :- The tenderer shall see the site closely and minutely with regard to the nature of the soil, average depth of decomposed garbage and debris at proposed Mast locations and the other site conditions before working out the type of foundation and specifications for the proposed High Mast. The tenderer shall be responsible for the design of the foundation and safe erection and installation of the High Mast in mechanically and structurally safe working condition for the design life of the Mast as per manufacture design The load bearing (safe) capacity of the soil shall be indicted by purchaser to decide the type of foundation and its specifications. The holding down bolts shall be at least 20 nos. of high tensile strength and shall be supplied complete with anchor plate of 6 mm thick for casting into the foundation. The ensure correct vertically and horizontality of bolt alignment. ( Note : Cost of foundation as per specification of manufacturer shall be deemed to be included in the rate quoted by the contractor) |
| 48 | (e) LANTERN CARRIAGE :- The fabricated lantern carriages shall be provided for holding fittings and control gear provided on each High Mast. The lantern carriage shall be of special design and of durable steel tube construction designed to act as electric conduit with cable holes fully protected by grummets. The diameter of the lantern carriage shall be suitable so as to hold designed number of LED floodlight fittings of 150Watt , as specified in the tender design along with the control gear boxes and lantern. The lantern carriage shall be fabricated in three parts joined by bolted flanges with SS bolts with nuts to enable easy removal from the erected mast for replacement/ maintenance purpose. The carriage shall be supported/ suspended by three wire ropes for better stability. The lantern carriage Assembly shall not touch the lower surface of the Mast. The carriage design and fabrication shall be such that the lantern carriage will suit the lanterns and their control gear boxes to be used in the work. The Lantern Carriage shall be so installed that it does not cause any damage to the surface of the Mast and is provided with protective buffer arrangement. The complete Lantern carriage shall be hot dip galvanised after fabrication. The weather - proof cast aluminum junction boxes (IP-66) shall be provided on the Lantern carriage assembly from which the inter- connections will be made to the designed number of floodlight fittings and lanterns on the carriage. |
| 49 | (f) MECHANICAL ARRANGEMENT :- For installation and maintenance purpose, it will become necessary to raise or lower the lantern carriage assembly. To enable this, a suitable winch arrangement shall be provided in the base of the Mast, complete with top pulley, winch stainless steel wire ropes and winch driving power tool. (i) WINCH :- The winch shall be of completely self-sustaining type. the winches shall be of self- sustaining type by means of an oil bath and the lubrication shall be of recommended quality. Termination of the ropes of the winch shall be in such a way, that it does not involve distortion or twisting of the rope configuration. At least 6 turns of rope shall remain in tension on the drum even when the lantern carriage is fully lowered. the winch shall be designed to be installed or removed form the door opening at the base of the mast. The winch drums shall be grooved to ensure mechanically strong, stable and tidy rope lay with no chances of rope slippage or skippage. The winch shall be capable of operation by hand or by means of external power tool. Integrated power tool with worm is not acceptable. A test certificate shall be supplied along with each winch in support of the maximum load operated by the winch and for the safety of operation at the full load rotation. A handle shall also be provided for hand operation of the winches. |
| 50 | (ii) TOP PULLEY ASSEMBLY :- The top pulleys shall be of a diameter, appropriately large enough to accommodate the steel wire ropes and the multicore electric cable. The material of construction of the pulley blocks shall be non- corrosive and made of dia cast (LM-6) aluminum alloy. The pulley assembly shall be complete with self lubricating bearing and stainless steel spindle. (iii) STAINLESS STEEL WIRE ROPES :- Stainless steel wire shall be AISC 316 grade 7/ 19 construction 2 Nos ropes for winch and 3 Nos for lantern carriage, 6 mm dia having a breaking load capacity of 2350 kg complete with stainless steel thimbles. The end for connection to the winch drum shall be fitted with thimbles and the thimbles shall be secured by copper compression splices. |
| 51 | (g) CABLE AND CABLE CONNECTIONS :- The connections shall be made with flat core flexible round sheath power cables of appropriate rating as per the schedule. The base compartment of the High Mast shall have one terminal box for terminating the incomer cable. The maintenance cables equal to that within the Mast and fitted with travelling cable 5 core 4 sqmm flexible having plug socket shall be provided to energize lanterns while in lowering position by hooking up at the base compartment socket supply. Similarly, the provision shall be made for electric supply at the base compartment to enable operation of the external power tool for lowering or rising of the lantern carriage assembly. The trailing cables of the lantern carriage rings shall be terminated by means of metal cased plug and socket provided in the base compartment to enable flexibility. |
| 52 | (h) WINCH DRIVING POWER TOOL :- The electric driven tool shall be single speed, (1.2 Mt/min) reversible three phase & hand operated motor. The power tool shall be complete with very robust remote control switch such that the tool can be operated from safe distance of 5 Mtrs. There shall be and arrangement for self alignment off power tool which can be self supported during operation. Manual handle shall be provided for hand operation of the winches. The capacity rating and speed of the electric motor used in the power tool shall be specified by the tenderers. |
| 53 | (j) LIGHTNING FINIAL & AVIATION OBSTRUCTION LIGHTS :- One number heavy duty hot dip galvanised lighting finial shall be provided for each mast. Suitable aviation obstruction lights of reliable design and reputed manufacturer shall be provided on top of each mast. |
| 54 | (k) LT OUTDOOR PANEL :- Fabricate, supply, install, test and commissioning of LT out door total enclosed Lt panel board of size 0.75 x 0.50 x 0.30 metre approx totally enclosed made out of 3mm thick CRCA sheet, dust and vermin proof with front opening 440V,3 Phase, 4 wire having 200 Amps capacity aluminium bus bar insulated with sleeves, incoming MCCB TPN 32 Amps 440 Volts,16 KA 01 No and copper wiring with multistranded cable including timer switch electronic type 01 No with necessary MCBs SP 6 Amps 06 Nos. contractors etc, cable glands, lugs and two coats of synthetic enamel paint over a coat of red oxide primer and making necessary pedestal 300mm height from floor level with PCC work complete all as specified. |
| 55 | Supply and fixing of LED flood light 170 watt and making arrangement for fixing of High mast list 16 mtr hight complete all as specified and directed |
| 56 | Note Tenderers may note that amount of credit Rs 1050065.00 will be deducted from the total amount arrived at the time of accceptance of contract Please Enable Macros to View BoQ information |