| 1 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in Man holes, roof slabs, chajjas, beams , fascias, fins and similar works complete all as specified and directed. |
| 3 | Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed. |
| 4 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed. |
| 5 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of diameter 75 to 110mm taking out of trenches and taking down from walls, if required complete all as specified and directed. |
| 6 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 150 mm taking out of trenches and taking down from walls, if required complete all as specified and directed. |
| 7 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 200mm taking out of trenches and taking down from walls, if required complete all as specified and directed. |
| 8 | Taking down cement plaster of any description on brick walls or concrete or stone and ceilings including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 9 | Cutting holes in brick walls built in cement mortar for taking out existing drains pipes and inserting old or new drain pipes of CI/RCC/SGSW/PVC/AC etc and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required complete all as specified and directed. |
| 10 | Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for internal pipe of dia 150mm complete all as specified and directed. |
| 11 | Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for internal pipe of dia 200mm complete all as specified and directed. |
| 12 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete, in foul conditions all as specified and as directed. |
| 13 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete, in foul conditions all as specified and as directed. |
| 14 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil, in foul conditions, complete all as specified and as directed. |
| 15 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point , in foul conditions, complete all as specified and as directed. . |
| 16 | M&L for Lean Cement Concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete and filling in Sunken portion complete all as specified and directed. |
| 17 | M&L for Lean Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete etc in sunken portion complete all as specified and directed. |
| 18 | M&L for Lean Cement Concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in surface channels and drains complete all as specified and directed. |
| 19 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.as in manhole pipe line portion only complete all as specified and directed. |
| 20 | M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 21 | M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after demolition of brick work. |
| 22 | M&L for brick work in half brick thick wall built in cement mortar (1:4) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 23 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roofkerbs or mud stops, rounded or chamfered on edges including form work complete all as specified and directed. |
| 24 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including form work complete all as specified and directed. |
| 25 | S&F 10mm dia and over mild steel TMT bars , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 26 | M&L for Providing precast cement concrete with reinforced cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles, with plain fair faces, including chamfers, weatherings, throat ing etc. and setting set in cement mortar (1:4) including necessary form work etc, complete all as specified and directed. (Note : Reinforcement shall be measured and paid for separately ) |
| 27 | M&L for 75mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed. |
| 28 | M&L for 75mm thick Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in sub floors, sub base of flooring, pavings surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed. |
| 29 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver blocks of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 30 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade (EXCEPT PAVER BLOCKS) with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. Note:- Old serviceable Paver Blocks shall be re-used under this item after proper cleaning etc. |
| 31 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on other than fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 32 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | M&L for preparing new plastered surfaces of walls and applying three coats of lime white wash complete all as specified and directed. |
| 34 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 35 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 36 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 37 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 38 | S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 39 | S&F 75mm dia PVC (SWR) bends any radius with oval type access door complete all as specified and directed. |
| 40 | S&F 110mm dia PVC (SWR) bends any radius with oval type access door complete all as specified and directed. |
| 41 | S&F 110mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal complete all as specified and directed. |
| 42 | S&F 110mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal provided with access door complete all as specified and directed. |
| 43 | S&F 75mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal complete all as specified and directed. |
| 44 | S&F 75mm dia PVC (SWR)Junction single (single or double \\"T\\") equal or unequal complete all as specified and directed. |
| 45 | S&F 110mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 46 | S&F in repairs 110mm dia PVC (SWR) \\"P\\" traps for Water Closets (IWC/EWC) complete all as specified and directed. |
| 47 | S&F in repairs110mm dia PVC (SWR) \\"S\\" traps for Water Closets (IWC/EWC) complete all as specified and directed. |
| 48 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 49 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 50 | S&F Stack clamps for 110mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 51 | S&F Stack clamps for 75mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 52 | S&F in repairs Vitreous China Squatting Pan, \\"Orissa pattern\\", size 580x440mm white/ coloured with integral foot rests (excluding flushing cistern, flush pipe and waste pipe), including trap and connection to trap, and to flushing pipe, anti-syphonage pipe, etc.complete including all joints and making good to floors complete all as specified and directed. |
| 53 | S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed. |
| 54 | M&L for cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in concrete bed for 150mm bore reinforced cement concrete pipes including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 55 | M&L for cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in concrete bed for 200mm bore reinforced cement concrete pipes including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 56 | S&F 150mm bore Reinforced concrete pipes, class NP-2, laid and jointed complete with collars laid in trenches and jointed complete all as specified and directed. Note:- Excavation, Earth work and Concrete bed shall be measured and paid separately) |
| 57 | S&F 200mm bore Reinforced concrete pipes, class NP-2, laid and jointed complete with collars laid in trenches and jointed complete all as specified and directed. Note:- Excavation, Earth work and Concrete bed shall be measured and paid separately) |
| 58 | M&L for cleaning of existing sewage line 100/110mm internal dia (bore) of pipes (SGSW/RCC/CI/PVC/AC) at any depth including manholes by removing the manholes covers of any type/ size and cleaning by means of dewatering sewage effluent with Honey Sucker Machine Tractor mounted followed by mechine/ vibration rodding followed by hydraulic jet pressure machine etc as required at site and well flushing the manholes with water after cleaning including getting out sludge/liquid materials if any in sewer line and removing the solids/ semi-solids and sludge and re instating the manhole covers in its original position as directed by Engineer-in-Charge . Note:- (i) The contractor will issue hand gloves to the Safaiwala before starting rodding/ sucking by means of mechanical sucker / bouser mounted tractor / lorry etc. (ii) Cleaning of existing sewage pipe line / manholes by suitable honey sucker followed by mechanical rodding followed by hydraulic jet pressure and disposing effluent, sludge, solid -semi-solid materials etc out side the MoD defence land in closed sewage tanker (iii) The labour employed by the contractor shall have firm name uniform, (iv) The Manhole cover to be re-installed. (v) Sludge shall also be removed in closed container outside MoD defence land and bleaching powder to be spread over waste sludge and covered with a layer of soil to maintain hygenic conditions (vi) Safety measures and Insurance of the Workmen shall be ensured by the contractor.(v) Distance from centre to centre of manholes shall be reckoned for purpose measurement and payment. (vi) All contractors to note also the Schedule \\"A\\" Notes to BOQ/ Schedule \\"A\\" and tender documents before qouting rates. |
| 59 | All as per Item No 58 here-in-before but 150mm internal dia (bore) of pipes (SGSW/RCC/CI/PVC/AC) at any depth |
| 60 | All as per Item No 58 here-in-before but 200mm internal dia (bore) of pipes (SGSW/RCC/CI/PVC/AC) at any depth |
| 61 | All as per Item No 58 here-in-before but 250mm internal dia (bore) of pipes (SGSW/RCC/CI/PVC/AC) at any depth |
| 62 | All as per Item No 58 here-in-before but 300mm internal dia (bore) of pipes (SGSW/RCC/CI/PVC/AC) at any depth |
| 63 | All as per Item No 58 here-in-before but 400mm internal dia (bore) of pipes (SGSW/RCC/CI/PVC/AC) at any depth |
| 64 | M&L for removing and cleaning the blockage of IWCs / EWC, bathroom/kitchen by cleaning the Nahani traps / Gully traps and CI / PVC pipe line upto the 1st manhole, removing all the sewage / sullage/ mud / sludge / kitchen waste / plants/ sand/ silt / foreign materials/ excreta etc and roots of shrubs and tress etc to be cut / removed and getting out by washing throughly traps, CI waste pipe by opening the cleaning eyes lids properly. The sludge/ waste received during cleaning process to be removed at a distance in a pit of suitable size at a distance not exceeding 100m from the bldg and bleaching powder to be spread over waste and burred under the soil / Earth, Earth work shall be included in the unit rate. Note:- (i) The Sweeper / safaiwala employed by the contractor shall be in possession of agency / firm dress, (ii) The sweeper / safaiwala shall be in possession of PVC / wooden pump of appropriate size with long handle / 5-6 mm dia MS plain rod. (iii) Cleaning blockage of IWCs / EWC, bathroom/kitchen by cleaning the Nahani traps / Gully traps and CI / PVC pipe line upto the 1st manhole, shall be considered as each job whether work is executed as a whole or in parts for a Dwelling Unit, for measurement and payment purpose. (v) All contractors to note also the Schedule \\"A\\" Notes to BOQ/ Schedule \\"A\\" and tender documents before qouting rates. Please Enable Macros to View BoQ information |
| 65 | M&L for removing and cleaning the blockage of IWCs / EWC, bathroom/kitchen by cleaning the Nahani traps / Gully traps and CI / PVC pipe line upto the 1st manhole, removing all the sewage / sullage/ mud / sludge / kitchen waste / plants/ sand/ silt / foreign materials/ excreta etc and roots of shrubs and tress etc to be cut / removed and getting out by washing throughly traps, CI waste pipe by opening the cleaning eyes lids properly. The sludge/ waste received during cleaning process to be removed at a distance in a pit of suitable size at a distance not exceeding 100m from the bldg and bleaching powder to be spread over waste and burred under the soil / Earth, Earth work shall be included in the unit rate. Note:- (i) The Sweeper / safaiwala employed by the contractor shall be in possession of agency / firm dress, (ii) The sweeper / safaiwala shall be in possession of PVC / wooden pump of appropriate size with long handle / 5-6 mm dia MS plain rod. (iii) Cleaning blockage of IWCs / EWC, bathroom/kitchen by cleaning the Nahani traps / Gully traps and CI / PVC pipe line upto the 1st manhole, shall be considered as each job whether work is executed as a whole or in parts for a Dwelling Unit, for measurement and payment purpose. (v) All contractors to note also the Schedule \\"A\\" Notes to BOQ/ Schedule \\"A\\" and tender documents before qouting rates. Please Enable Macros to View BoQ information |