| 1 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc complete all as specified and directed. |
| 2 | M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 3 | M&L for brickwork with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed. |
| 4 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and any other treatment like tarfelt etc., complete all as specified and directed. |
| 5 | M&L for rendering 15mm thick in cement mortar in 1:4 on external wall surfaces of brick work or concrete surfaces even and fair without using extra cement complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick in cement mortar 1:6 on internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 7 | M&L for rendering 10mm thick in cement mortar 1:3 on ceiling and finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for preparation of new plastered wall surface and finishing wall with two coats of Acrylic smooth exterior paint of required shade : (applied @ 1.67 ltr / sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm complete all as specified and as directed. |
| 9 | M&L for complete removal of existing treatment on old plastered wall surface and finishing wall with two coats of Acrylic smooth exterior paint of required shade : (applied @ 1.67 ltr / sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm complete all as specified and as directed. |
| 10 | M&L for preparation of new plastered Internal wall surface and applying two coats of distempering with Ist quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ltr, of approved manufacturer of required shade and colour complete as per manufacturer specification. |
| 11 | M&L for complete removal of existing treatment on old plastered wall surface and applying two coats of distempering with Ist quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ltr, of approved manufacturer of required shade and colour complete as per manufacturer specification. |
| 12 | M&L for preparing newly plastered or concrete surface of ceiling by sand papering or by the other mean and after preparing the surfaces and applying three coats of white wash with (paint brush/with roller) complete all as specified and directed. |
| 13 | M&L for preparing old plastered or concrete surface of ceiling by sand papering or by the other mean and after preparing the surfaces and applying two coats of white wash with (paint brush/with roller) complete all as specified and directed. |
| 14 | M&L for 2mm thick wall care putty on wall surfaces to make the surface smooth complete all as specified and as directed. |
| 15 | Cleaning all existing reinforcement bars in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturer’s instructions, complete all as specified and directed.Note :- Mode of measurement : per sqm of breaking area of concrete only. |
| 16 | Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturer's instructions but min 0.4 kg/Sqm approx) in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and directed.Note :- Mode of measurement: per sqm of application area of concrete. |
| 17 | Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed. |
| 18 | Rebuilding the section of structural damaged RCC/PCC elements of Roof, Ceiling, Chajja, Fascia, Fins, Drops repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79 complete all as specified and directed. |
| 19 | Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for, complete all as specified and as directed. |
| 20 | Supply & fixing for Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 21 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coasts of synthetic enamel paint (for steel surfaces) complete all as specified and directed. |
| 22 | M&L for preparation old previously treated surface of steel and iron work any description over 10 cm width or girth and applying one coat of synthetic enamel paint on old steel surfaces, complete all as specified and directed. |
| 23 | M&L for preparing old previously treated surface of wood and wood based surfaces exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint on old decorated wooden surfaces, complete all as specified and directed. |
| 24 | S&F 110 mm bore of pipe PVC (SWR) pipes single socket in any length with rubber ring joint fixed to walls with projected galvanised MS clamps as specified, and also repair to blow holes/spouts and mouth of pipe for leak proof purpose including taking down old AC eaves gutter and rain water pipes (any size and pattern) including all fittings complete all as specified and directed. |
| 25 | S&F in repair 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes complete all as specified and directed. |
| 26 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above gound level) complete all as specified and directed. |
| 27 | M&L for 75mm thick Cement Concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in plinth protection complete all as specified and directed. Please Enable Macros to View BoQ information |