| 1 | Supply, installation, commissioning and testing of window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.5 TR capacity having ISEER minimum 3.5 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification complete all as specified & directed. |
| 2 | Supply, installation, commissioning and testing of wall mounted air cooled split units indoor/outdoor complete with cordless remote control unit electric drive single phase of capacity 2 Ton, 5 star rated and EER 3.2 of capacity as shown with in built air ioniser and Plasma filter for better indoor air quality of capacity 2 TR complete with all accessories including making all arrangement for fixing indoor & outdoor units with stand, making necessary hole with bracket in wall to pass tubing and cables and grounting bolt in wall, connecting suction & discharge of copper tubing and cables, copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length as per site including insulating piping & Gas Charging complete all as specified & directed. |
| 3 | Supply, installation, commissioning and testing of wall mounted air cooled split units indoor/outdoor complete with cordless remote control unit electric drive single phase of capacity 1.5 Ton, 5 star rated and EER 3.2 of capacity as shown with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 TR complete with all accessories including making all arrange ment for fixing indoor & outdoor units with stand, making necessary hole with bracket in wall to pass tubing and cables and grounting bolt in wall, connecting suction & discharge of copper tubing and cables, copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length as per site including insulating piping & Gas Charging complete all as specified & directed. |
| 4 | Supply, installation, commissioning and testing of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 150 ltrs & storage capacity of 150 ltrs water cooler 5 star rated complete all as specified and directed. |
| 5 | Supply, installation, commissioning and testing of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 60 ltrs & storage capacity of 120 ltrs water cooler 5 star rated complete all as specified and directed. |
| 6 | Supply, installation, commissioning and testing of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40 ltrs & storage capacity of 80 ltrs water cooler 5 star rated complete all as specified and directed. |
| 7 | Supply, installation, commissioning and testing of refrigerator electric driven (single phase) capacity 310 ltr, double door, 230 volts and cool lock technology including tempered glass tray, pocket handle, great bottle storage space & bigger vegetable basket R-600 A compressor, inbuild voltage stablizer, 5 star rated inverter type complete all as specified and directed. |
| 8 | Supply, installation, commissioning and testing of refrigerator electric driven (single phase) capacity 195 ltr, 230 volts and cool lock technology including tempered glass tray, pocket handle, great bottle storage space & bigger vegetable basket inbuild stablizer, 5 star rated inverter type complete all as specified and directed. |
| 9 | Supply, installation,commissioning and testing of Glass Top Deep Freezer single phase 240 volt, 50 Hz 320 Ltr capacity, 5 star rated complete all as specified and directed. |
| 10 | Supply,installation, commissioning and testing of desert cooler (evaporative air cooler) duct type having normal cooling capacity of 120 cu.m per minute, 230/250V, 50Hz with 17\\" exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dBA at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed etallic parts, shall be provided with proper earthling complete all as specified and directed. |
| 11 | M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete including dummy switches wherever required all as specified and making good disturbed surfaces applying putty /distemper/whitewashiungetc for one 3 pin 5 amp socket outlet point on the independent board controlled by one, one way switch. Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 12 | All as per item Sl No 11 above here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point. |
| 13 | All as per item Sl No 11 above here in before but wiring with 4.0 sqmm multi stranded cable and earth wire with copper conductor of size 4.0 sqmm for 15 amps power point. |
| 14 | M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the following sizes :- 2x2.5 Sqmm with earth wire of 1x2.5 Sqmm. Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same make. |
| 15 | As per item No 14 above but 2x1.50 Sqmm with earth wire of 1x1.5 Sqmm. |
| 16 | As per item No 14 above but 2x4.0 Sqmm with earth wire of 1x4.0 Sqmm. |
| 17 | Supply and fix Modular switch one way 6A, 1 module complete all as specified and directed |
| 18 | Supply and fix Modular switch one way 16A, 1 module complete all as specified and directed |
| 19 | Supply and fix Modular Socket 6A 2/3 pin combined 2 module complete all as specified and directed |
| 20 | Supply & Fix Modular Socket 6A/ 16A 2/3 pin combined 2 module complete all as specified and directed |
| 21 | Supply & Fix modular 20 Amp Heavy Duty MCB COMBO Box, 4 module with MCB SP of capacity 20 Amp, for AC complete all as specified and directed. |
| 22 | Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundations, laying of pipes/cables/poles etc and getting out in soft/loose soil complete all as specified and directed. |
| 23 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick each layers as in soil complete all as specified and directed. |
| 24 | Removing excavated material/soil to a distacne not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specefied and as directed. |
| 25 | Supply & fixing in repair Ball valves for pipe size 15mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25-455gms) and fixed ISI Marked approved quality complete all as specified and directed. |
| 26 | Supply and fix GI tubing and fitting, 15 mm bore medium grade from wall/ trenches and disconnecting from main distribution lines including taking up or down and necessary cutting of existing pipe line complete all as specified and as directed. |
| 27 | Supply & fixing in repair 15 mm bore gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe, jointing and testing ISI Marked approved quality, complete all as specified and directed. |
| 28 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type for window AC & designed for input variation between 90 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA |
| 29 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type split AC & designed for input variation between 90 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA |
| 30 | Supply and fix Stand for Outdoor Unit of Split Air Condioner of any capacity and any size, complete all as specified and directed |
| 31 | Supply & replacement of copper tubing including cutting brazing, flaring and testing of size 1x1/2”x 22 SWG in required length including insulating piping with taflon tape complete all as specified and directed. |
| 32 | Supply & replacement of copper tubing including cutting brazing, flaring and testing of size 1x3/8”x 22 SWG in required length including insulating piping with taflon tape complete all as specified and directed. |
| 33 | Supply & fixing , Rigid non-metallic PVC conduit of size 20mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends andfixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed. |
| 34 | Material and labour for PCC Type D2 ,1:3:6 by using ( 40 mm aggregatestone aggregate) upto 60 cm in height, cfor base of water cooler etc, complete all as specified and directed. |
| 35 | Supply and fix Flame Retardant (FR) PVC casing caping of Size 3\\" (75 mm), Ivory/white Colour, Unplasticised formulation for prolong storage or usage, double lock, ISI Marked as per IS 14927, Highly durability, Resistance to oil and grease, complete all as specified and directed. |
| 36 | M&L for framed work such as stand for AC, cooler, grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed including painting with two coats of synthetic enamel paint/ lead free black bituminous paint as directed over a coat of zinc chrome primer. Complete all as specified and directed |
| 37 | Supply only heavy duty adjustable stand for refrigerator/deepfreezer upto 310 Ltrs capacity, ISI marked complete all as specified and as directed. |
| 38 | Supply only heavy duty adjustable stand for refrigerator/deepfreezer above 310 Ltrs capacity, ISI marked complete all as specified and as directed. Please Enable Macros to View BoQ information |