Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 2 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 3 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 4 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 5 | Providing and fixing, in position concealed G.l. section for wall paneling using board of required thickness fixed on the 'W profile (0.55 mm thick) having a knurled web of 51.55 and two flanges of 26mm each with lips of 10.55mm placed @610mm c/c mm with thickness of 0.55 mm and web in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the W profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 8 mm thick cement bonded wood particle board as per IS:14276. |
| 6 | 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 7 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 8 | Supply, Fitting and Fixing football changing dressing area, 19mm plywood, 1mm thickness laminated, botom seating bench with cushion, open hanging section for jersey (seating area diamention size - 84x40x24mm). as per direction of E/I |
| 9 | Godrej NX Pro Digital (15L) Ebony Home Locker |
| 10 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. (Group C) |
| 11 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 12 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 13 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 14 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 15 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 16 | 5/6 amps, one way switch |
| 17 | 5/6 amps, 3 pin socket outlet |
| 18 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 19 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 20 | ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required. |
| 21 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. |
| 22 | 6/32, single pole, \\"B\\" series |
| 23 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 24 | 40 amp |
| 25 | 63 amp |
| 26 | S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22 W LED Tube light |
| 27 | 15/16Watt LED Bulb |
| 28 | 1200mm (48\\") Ceiling Fan |
| 29 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 30 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 31 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. (600MM X 1200MM) |
| 32 | Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes |
| 34 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 35 | Coupler - 110mm |
| 36 | Bend - 110mm |
| 37 | Shoe - 110 |
| 38 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete |
| 39 | 110 mm |
| 40 | 110mm |
| 41 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 42 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 43 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 44 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. Frame size 50 x 125 mm |
| 45 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 46 | Sand lead = 10 km |
| 47 | \\"Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.\\" |
| 48 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 49 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 50 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 51 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 52 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 53 | 5/6 amps, one way switch |
| 54 | 5/6 amps, 3 pin socket outlet |
| 55 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 56 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 57 | ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required. |
| 58 | ITC exhaust fan upto 450 mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 59 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. |
| 60 | 6/32, single pole, \\"B\\" series |
| 61 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 62 | 40 amp |
| 63 | 63 amp |
| 64 | Cable Laying of 1.1 KV & 11 KV :- |
| 65 | S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22 W LED Tube light |
| 66 | 15/16Watt LED Bulb |
| 67 | Supply fitting fixing and testing of 12\\" (300mm) metal exhaust fan : Make as per approved by E/I. |
| 68 | 1200mm (48\\") Ceiling Fan |
| 69 | Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I. |
| 70 | 25 mm dia |
| 71 | 32 mm dia |
| 72 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. |
| 73 | 125 mm thick wall |
| 74 | 250 mm thick wall |
| 75 | Jaquar - Swivel Mirror 630mm x 445mm |
| 76 | Jaquar - WC Area - Concealed Cistern with frame & required fittings (jaguar) |
| 77 | Jaquar - Table mounted wash hand basin with required fittings (jaguar) |
| 78 | Jaquar - Urinal Area - (Sensor Battery Operated) |
| 79 | Jaquar - Bib Cock with wall flange |
| 80 | Jaquar - Concealed stop cock for 15mm pipeline with exposed top part |
| 81 | Jaquar - shower with towel rail |
| 82 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 83 | Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I.150mm dia |
| 84 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 85 | 75 mm diameter |
| 86 | 110 mm diameter |
| 87 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 88 | Single tee without door - 75x75x75 mm |
| 89 | Single tee without door - 110x110x110 mm |
| 90 | 75 mm bend |
| 91 | 110 mm bend |
| 92 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 93 | 25 mm nominal outer dia Pipes |
| 94 | 32 mm nominal outer dia Pipes |
| 95 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 96 | 15 mm nominal outer dia Pipes |
| 97 | 20 mm nominal outer dia Pipes |
| 98 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 99 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. |
| 100 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 101 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, |
| 102 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 103 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 104 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 105 | Providing designation 75 A brick work in C.M. (1: 4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 106 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 107 | Regarding of VIP chairs, Providing and fixing of F11002 HDPE Floor mount Seat with hand rest. as per specification and color mention 70% blue and 30% Grey. Double-wall hollow blow mold bucket type seat having minimum dimensions as 500 mm side length x 460 mm front width x 420 mm rear height in one piece of HDPE having minimum shell thickness of 2.5-3 mm on each wall. Minimum seat density of 0.95 gram/cm3, weight of plastic chair should not be less than 2.6 kg. Chair should withstand in high temperature not less than 70°C with ultraviolet stabilizer and colour fastness, having ergonomic design, seat to be fixed on Aluminium floor mount frame by the process of grouting with bolt. The chair should be fixed with Metal Inserts moulded inside seat to connect seat with Galvanized pipes 32mm OD tube and 2 mm thickness running under the chairs. The pipes are resting above Aluminium bracket at c/c distance from 1.0 to 1.5 mtr and all open ends of all pipes are to be closed by PVC cap. Water should not accumulate on chair. Chair should have a warranty of 2 years against significant colour fading and 3 year against breakage due to manufacturing. The seat pass BSEN 12520: 2015 & EN 12727: 2016 Test. Chair Plastic Part should have been tested with xenon -Arc exposure Test as per ISO 4892-2:2013. test report. As per Direction of Encharge. |
| 108 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required (Group C) |
| 109 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 110 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 111 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 112 | 2 x 4.0 sq.mm. + 1 x 4.0 sq.mm. earth wire |
| 113 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 114 | 5/6 amps, one way switch |
| 115 | 5/6 amps, 3 pin socket outlet |
| 116 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 117 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 118 | ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required. |
| 119 | ITC exhaust fan upto 450 mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 120 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. |
| 121 | 6/32, single pole, \\"B\\" series |
| 122 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 123 | 40 amp |
| 124 | 63 amp |
| 125 | Cable Laying of 1.1 KV & 11 KV :- |
| 126 | S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22 W LED Tube light |
| 127 | 15/16Watt LED Bulb |
| 128 | Supply fitting fixing and testing of 12\\" (300mm) metal exhaust fan : Make as per approved by E/I. |
| 129 | 1200mm (48\\") Ceiling Fan |
| 130 | 100 W COB LED HIGHBAY LIGHT |
| 131 | 15/16 amps, one way switch |
| 132 | 15/16 amps, 6 pin socket outlet |
| 133 | CASSET A.C. |
| 134 | CASSET A.C. VVIP & VIP AREA (6000 SFT) |
| 135 | CASSET A.C. Equipments (for 12 AC) |
| 136 | 6 pin 15/16 amps, socket outlet |
| 137 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. |
| 138 | 15 mm dia |
| 139 | Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I. |
| 140 | 25 mm dia |
| 141 | 32 mm dia |
| 142 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. |
| 143 | 125 mm thick wall |
| 144 | 250 mm thick wall |
| 145 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. |
| 146 | Mirror (300 x 450mm) |
| 147 | Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580mm long - With 12.5 lit. low level PVC cistern |
| 148 | In Each W.C. |
| 149 | Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I.With 'P' trap - 12.5 lit low level PVC Cistern |
| 150 | In Each W.C. |
| 151 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 152 | Supplying, fitting and fixlng flat back or angular, lipped front vitreous white glazed earthen ware urinal of 'Hindustan 'Parry\\" or any other approved l.S.S make wifi 5 liters capacity C.l. automatic fulsing cistern of reliance for any other l.S.S. approved make with all fittings with C,l.or R.S. brackets, standard size G.l. flush pipe with fitting clamps.lSmm C.1. bodv brase splndle stoo cock of aoDroved oualitv |
| 153 | (a) Flat back or standing corner (600mmx350mm) |
| 154 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 155 | Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I.150mm dia |
| 156 | Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges -Special type of C.P. Bath room fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark) |
| 157 | (ii) Pillar Cock (Long neck) (lSl Marked) |
| 158 | (iii) Bib Cock (Long Thread) (lSl Marked) |
| 159 | (a) 12.5 Litres lowdown C.l. Cistem (lSl Marked) |
| 160 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 161 | 75 mm diameter |
| 162 | 110 mm diameter |
| 163 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 164 | Single tee without door - 75x75x75 mm |
| 165 | Single tee without door - 110x110x110 mm |
| 166 | 75 mm bend |
| 167 | 110 mm bend |
| 168 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 169 | 25 mm nominal outer dia Pipes |
| 170 | 32 mm nominal outer dia Pipes |
| 171 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 172 | 15 mm nominal outer dia Pipes |
| 173 | 20 mm nominal outer dia Pipes |
| 174 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 175 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. |
| 176 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 177 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 178 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 179 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. |
| 180 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 181 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 182 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 183 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 184 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 185 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 186 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio). |
| 187 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 188 | Bricks Lead = 1 k+7 P(8km) |
| 189 | SAND av. lead -10 K.M |
| 190 | Stone metal lead = 22 km |
| 191 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.(Group C) |
| 192 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 193 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 194 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire (for Single Separate 5A from nearest switch board and wall fans) |
| 195 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 196 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 197 | 5/6 amps, one way switch |
| 198 | 5/6 amps, 3 pin socket outlet |
| 199 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required |
| 200 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 201 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 202 | ITC exhaust fan upto 450mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required. |
| 203 | Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 204 | 8 way, single door |
| 205 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. |
| 206 | 6/32, single pole, \\"B\\" series |
| 207 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 208 | 40 amp |
| 209 | Supplying and fixing of 9/10 Watt LED Bulb |
| 210 | Supplying and fixing LED Batten (20/22W) |
| 211 | Supply of 12\\" (300mm) metal exhaust fan |
| 212 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. |
| 213 | 15 mm dia |
| 214 | Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I. |
| 215 | 25 mm dia |
| 216 | 32 mm dia |
| 217 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. |
| 218 | 125 mm thick wall |
| 219 | 250 mm thick wall |
| 220 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. |
| 221 | Mirror (300 x 450mm) |
| 222 | C.P. brass tower rail |
| 223 | C.P. brass soap container medium quality with screw and hinges etc. |
| 224 | Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580mm long - With 12.5 lit. low level PVC cistern |
| 225 | In Each W.C. |
| 226 | Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I.With 'P' trap - 12.5 lit low level PVC Cistern |
| 227 | In Each W.C. |
| 228 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of 'Hindustan \\"Parry\\" or any other approved I.S.S. make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S., brackets, standard size G.I. flush pipe with fitting clamps, 15mm, C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting coat of red oxide cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. |
| 229 | (a)Flat back or Standing Cornar |
| 230 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 231 | Supplying, fitting and fixing vitreous white glazed earthen ware indian squating type 600x350mm urinal plate of parry, Hindustan or any other l.S.S. approved make with internal flushing rim, 100mm white glazed earthen ware channelabout 1m. long 5litre capacity C.l. automatic flushing cistern of reliance or any other approved make with fittings R.S. or C.l. brackets 1Smm and 45 cm long PVC / Alkathene pipe standard G.l: flush pipe for backand front with spreader fittings and brass coupling etc. 15 mm C.l. Body'brass spindle stop cock weight not less than 450 grams. all complete including painting of exposed parts with 2 coats of approved paint over a coat of red oxide primer and cutting the wall and floor and making good the same as oer soecification and direction of E/|. |
| 232 | (b) 450 mm x 350 mm size (small) |
| 233 | Providing and fixing N.P/ C.P. Brass/ P.V.C. Porcelain shower rose of 15mm inlet etc. All complete as per specification and direction of E/I. |
| 234 | (C) 150mm dia P.V.C. Shower |
| 235 | Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges -Special type of C.P. Bath room fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark) |
| 236 | Pillar cock |
| 237 | bib cock |
| 238 | Angular Stopcock /2 way bib cock |
| 239 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 240 | 75 mm diameter |
| 241 | 110 mm diameter |
| 242 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 243 | Single tee without door - 75x75x75 mm |
| 244 | Single tee without door - 110x110x110 mm |
| 245 | 75 mm bend |
| 246 | 110 mm bend |
| 247 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 248 | 25 mm nominal outer dia Pipes |
| 249 | 32 mm nominal outer dia Pipes |
| 250 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 251 | 15 mm nominal outer dia Pipes |
| 252 | 20 mm nominal outer dia Pipes |
| 253 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 254 | Providing and applying Thermoflex P-111 /Sika Coolcoat or any other Equivalent compound on Roofs of Slab as per following procedure- |
| 255 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 256 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 257 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 258 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 259 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required(Group C) |
| 260 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 261 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 262 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 263 | 2 x 4.0 sq.mm. + 1 x 4.0 sq.mm. earth wire |
| 264 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 265 | 5/6 amps, one way switch |
| 266 | 5/6 amps, 3 pin socket outlet |
| 267 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 268 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 269 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. |
| 270 | 6/32, single pole, \\"B\\" series |
| 271 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 272 | 40 amp |
| 273 | 63 amp |
| 274 | Cable Laying of 1.1 KV & 11 KV :- |
| 275 | S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22 W LED Tube light |
| 276 | 15/16Watt LED Bulb |
| 277 | 100 W COB LED HIGHBAY LIGHT |
| 278 | Removal of All the concrete and earth upto mother surface demarcated for expansion joint |
| 279 | Sealing the expansion joint in mother surface with the gap of 25mmx50mm with polysulphide sealent after the insertion of thermocol to make the define depth and width as mentioned. |
| 280 | Anchoring steel of 8mm at the gap of 150mm upto height 300 on both sides of Expansion joint with Barfix ( Resin grout on either side of the expansion joint. |
| 281 | Pouring of Micro concrete of 75mm with MC 40 With shuttering support of 6mm ply on either side of expansion joint to make the elevated expansion joint upto the height of the excavated earth and concrete . |
| 282 | Providing and Fixing Baker Rod material:Providing ,Fixing and Inserting incompressible shalitex board /Kaizen Foam as back material into existing groove from both roof ( terrace and ceiling ) |
| 283 | Providing and Applying: Providing and applying labond E FLEX adhesive along the both sides of expansion joint on the prepared substrate with notch trowel or spatula.Fixing /pasting Fixing/pasting the Expansion joint tape of 2mm thickness 200mm width covering both egde of expansion joint up to minimum 50 mm each side. Further coat of Labond E FLEX Adhesive on expansion Joint TPE |
| 284 | Prepare Coving at the junction of micro wall of 75mmx75 mm with Polymer modified mortor admixed with SBR Latex |
| 285 | Waterproofing Coarse : Apply two coats of two Component Cementitious Coating of Fibreflex Extra on entire exposed mother surface After applying Brushseal Primer |
| 286 | Protection of Expansion joint tape :Providing and Fixing of 2mm alumunium sheet of 200 mm width over the expansion joint tape by drilling SS screw on one side and other side fixed by SS screw duly slotted for easy movement during expansion and contraction . |
| 287 | Fixing Nozzles |
| 288 | Providing & fixing 6mm dia PVC nozzle(PU Grouting ) @ 200 mm c/c along the Construction joint or at other locations with with quick setting compound ,Terraplug . (All required staging,scaffolding,& the removal of scaffolding after work is over- all in client scope) PU INJECTION |
| 289 | Covering of treated surface with PCC :- Providing 50 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm TAKE 16% |
| 290 | Providing and supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) confirming to lS 49841 14151 I12786 I 13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread / insert joint /quick release coupler joint / compression fitting joint or flanged joints excluding coupler / specials and taxes).Note :- The Rates are F.O.R at worksite in Jharkhand including Royalty, inspection Charges and other taxes but excluding GST & C.P. HDPE pipe of materials qrade PE80-PN06 (dia in mm) 200 mm dia |
| 291 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 292 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. |
| 293 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 294 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 295 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 296 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 297 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 298 | Bricks Lead = 1 k+7 P(8km) |
| 299 | SAND av. lead -10 K.M |
| 300 | Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I. |
| 301 | 25 mm dia |
| 302 | 32 mm dia |
| 303 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. |
| 304 | 125 mm thick wall |
| 305 | 250 mm thick wall |
| 306 | Jaquar - Swivel Mirror 630mm x 445mm |
| 307 | Jaquar - WC Area - Concealed Cistern with frame & required fittings (jaguar) |
| 308 | Jaquar - Table mounted wash hand basin with required fittings (jaguar) |
| 309 | Jaquar - Urinal Area - (Sensor Battery Operated) |
| 310 | Jaquar - Bib Cock with wall flange |
| 311 | Jaquar - Concealed stop cock for 15mm pipeline with exposed top part |
| 312 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 313 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 314 | 75 mm diameter |
| 315 | 110 mm diameter |
| 316 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 317 | Single tee without door - 75x75x75 mm |
| 318 | Single tee without door - 110x110x110 mm |
| 319 | 75 mm bend |
| 320 | 110 mm bend |
| 321 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 322 | 25 mm nominal outer dia Pipes |
| 323 | 32 mm nominal outer dia Pipes |
| 324 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 325 | 15 mm nominal outer dia Pipes |
| 326 | 20 mm nominal outer dia Pipes |
| 327 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.(Group C_ |
| 328 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 329 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 330 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire (for Single Separate 5A from nearest switch board and wall fans) |
| 331 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 332 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 333 | 5/6 amps, one way switch |
| 334 | 5/6 amps, 3 pin socket outlet |
| 335 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required |
| 336 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 337 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 338 | ITC exhaust fan upto 450mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required. |
| 339 | Supplying and fixing of 9/10 Watt LED Bulb |
| 340 | Supplying and fixing LED Batten (20/22W) |
| 341 | Supply of 12\\" (300mm) metal exhaust fan |
| 342 | 100 W COB LED HIGHWAY LIGHT |
| 343 | Football Goal post movable in ground type made of 4” dia Heavy MS pipe size 24’ x 8’with 1.5” back support and Co Polymer wheels. Special net lock made of PVC for easily hanging the net. Made according to FIFA approved design and specifications. Fully welded corner joints provide superior strength and added safety for players. Use of branded MRF Epoxy paint. |
| 344 | Football Net for Fixed Goal Post – Garware Tournament |
| 345 | 12 seater Dugout top made of 2” x 2” square pipe and base made of 100mm x 50mm square heavy MS pipe with non-marking wheels for synthetic surfaces. 2.5mm polycarbonate sheet made by 100% virgin LEXAN material UV stabilized. Length: 20’, Height: 7’ |
| 346 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 347 | Camera platform (35kg/sqm) |
| 348 | SlTC of 63 mm tire hydrant landing valve |
| 349 | SITC o(hose cabinet double door tvoe |
| 350 | SITC of short branch nozzle type |
| 351 | SITCof RRL hose I5 mtr. Capacity |
| 352 | SlTC of hose reel drum set30 mtr. Capacity |
| 353 | Refilling. of A..B.C. tvne fire extinguishers 9 kg |
| 354 | Refilling of A.B.C. tvoe fire extinguishers 6 kn |
| 355 | Refilling ofC01gas type fire extinguishers 4.5 kg |
| 356 | Testing checking. of Diesel engine fire pump |
| 357 | Testing checking of Centrifuge electrical fire pump |
| 358 | Testing checking of electrical jockey stand by punp |
| 359 | testing checking of fire alarm system |
| 360 | testing checking of main electrical control panel for all electrical fire pumps |
| 361 | SITC of I00 mm MS Pipe for ring line |
| 362 | Pressure gauge for fire pumps |
| 363 | fitting accessories and installation & painting |
| 364 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 365 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 366 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 367 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 368 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. |
| 369 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 370 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 371 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin-Charge. |
| 372 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 373 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 374 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. |
| 375 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5 M all complete as per building specification direction of E/I. (Mode of measurement compacted volume) |
| 376 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 377 | Providing designation 75B work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 378 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 379 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 380 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 381 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 382 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 383 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge. |
| 384 | Supplying and stacking at site dump manure from approved source, including carriage up to 1km (manure measured in stacks will be reduced by 8% for payment) |
| 385 | Same as good earth |
| 386 | Fine dressing of the ground |
| 387 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and/or good earth to be paid seprately |
| 388 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 389 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 390 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 391 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 392 | Bricks - 8km |
| 393 | SAND av.LEAD 10 K.M |
| 394 | Stone Metal lead - 22km |
| 395 | Local Sand - 3 km |
| 396 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. |
| 397 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 398 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 399 | Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 400 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 401 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 402 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 403 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 404 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 405 | Providing TMT steel reinforcement above 16mm to 36mm dia bars as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. |
| 406 | 10mm dia |
| 407 | 12mm dia |
| 408 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 409 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 410 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 411 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 412 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 413 | Bricks - 8km |
| 414 | SAND av.LEAD 10 K.M |
| 415 | Stone chips lead 22km |
| 416 | Local Sand - 3 km |
| 417 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 418 | 75 mm diameter |
| 419 | 110 mm diameter |
| 420 | 75 mm bend |
| 421 | 110 mm bend |
| 422 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 423 | 25 mm nominal outer dia Pipes |
| 424 | 32 mm nominal outer dia Pipes |
| 425 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 426 | 15 mm nominal outer dia Pipes |
| 427 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 428 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages5 HP |
| 429 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I. |
| 430 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 431 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge. |
| 432 | 50 mm nominal outer dia Pipes |
| 433 | 2.0Tr. 5 Star Split A.C (lnverter Type) IS 1391-part-I |
| 434 | Copper Tube of size 1/2\\" for split ac unit 1/1.5/2/3 tr capacity including nitride rubber insulation |
| 435 | Drain Pipe for A |
| 436 | Outdoor stand for 2.0Tr Split AC |
| 437 | 4 KVA wall mounted automadc voltage stablizer from range 140V to 280V |
| 438 | 6 pin 15/16 amps, socket outlet |
| 439 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 440 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 441 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 442 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 443 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 444 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 445 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 446 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 447 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 448 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 449 | Providing Toe steel reinforcement of 8mm dia to 32mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (TMT coil Fe 500) {Only Valid for TATA (TISCON) SAIL, JSPL, Electrosteel Steels ltd. Bokraro & Vizag(RINL)} |
| 450 | 8# dia@ 60% |
| 451 | 12# dia@ 40% |
| 452 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I. |
| 453 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 454 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I. |
| 455 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. |
| 456 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes |
| 457 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 458 | Coupler - 110mm |
| 459 | Bend - 110mm |
| 460 | Bricks Lead = 1 k+7 P(8km) |
| 461 | Sand lead = 10 km |
| 462 | Stone chips lead = 22 km |
| 463 | Stone metal lead = 22 km |
| 464 | Local Sand lead = 3km |
| 465 | Supplying and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 grms) with extra socket all complete as per specification and direction of E/I. |
| 466 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. |
| 467 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I. |
| 468 | Making holes in walls for laying H.C.I. Pipes and restoring the same after pipe laying as per specification and direction of E/I/ |
| 469 | Providing and supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) 25mm to 500mm dia confirming to lS 4984 I 14151 I 12786 I 13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread / insert joint / quick release coupler joint / compressionfitting joint or flanged joints excluding coupler / specials and taxes. Note :- The Rates are F.O.R at worksite in Jharkhand including Royatty, inspection Charges and other taxes but lexcluding cST & C.P.. |
| 470 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of |
| 471 | 15 mm nominal outer dia |
| 472 | 25 mm nominal outer dia |
| 473 | Polythene water storage tank of ISI mark (eg Sintex /Sinter /himgiri/gangotri etc with cover & locking system |
| 474 | SWIMMING POOL LOUNGE CHAIR:- Supply and Providing Specification:- Crafted with an outer frame of white-finished resin wicker wrapped around an inner MS frame, each chaise is weather-, water-, and UV-resistant, making them perfect for living on your patio or deck. Plus, each one features five reclining positions (including fully flat) to help you get comfortable. Best of all, they arrive fully assembled with included cushions, you can stretch out and lounge as soon as it arrives. Water Resistant, UV light Resistant, Colourfast, Handwoven with Synthetic rattan. Dimension(in):- 78L/31D/38H. |
| 475 | SWIMMING POOL SIDE CHAIR:- Supply and Providing Specification:- Crafted with an outer frame of white-finished resin wicker wrapped around an inner MS frame, each chaise is weather-, water-, and UV-resistant, making them perfect for living on your patio or deck. Plus, each one features five reclining positions (including fully flat) to help you get comfortable. Best of all, they arrive fully assembled with included cushions, you can stretch out and lounge as soon as it arrives. Water Resistant, UV light Resistant, Colourfast, Handwoven with Synthetic rattan. Dimension(in):- 32L/17D/18H. |
| 476 | INDOOR WICKER PLANTERS:- Supply and Providing Specification:- These flower pots are a great way to spruce up your patio. Made with top-quality wicker and a metal frame these are both simple and elegant. Put any plant you want to show off in them or use them to start a small herb garden. However you decide to use them, these flower pots are a must-have. Water Resistant, UV light Resistant, Color Fast, Material Color: Grey, Item Weight: 20 Kg, Finish: Handwoven With Synthetic Rattan, Dimension(in):-31'' H X 11'' W X 11'' D |
| 477 | ARTIFICIAL PLANT FOR INDOOR:- Supply and Providing Specification:- The height of the bamboo pole, Tree Leaf etc is 4.5ft, and after inserting the top bamboo leaf, the height is 5ft. Like Apperrance :If you don't like the green film, you can peel it off to reveal the actual bamboo poles underneath. You don't need to worry about taking care of your artificial tree anymore. Our artificial tree does not need daily watering and pruning, just a simple rinse or wipe off the dust will keep it green. |
| 478 | COB LIGHT:-Supply and Providing Specification:- High quality Bridgelux COB LED light source, CRI>90Ra and 90Ra for option, soft light with high lumen. The lamp body is made of thickened aluminum material, and the surface is anodized, polished, frosted, etc., and the lamp body is not easy to rust. 20Watt Full Spectrum Warm/White Led COB Chip Grow Light Growth Lamp Garden Hydroponic Plant. |
| 479 | WATER SOFTENERS:- Supply and Providing Specification:- Water quality is a fundamental aspect of daily living, yet millions of households struggle with hard water issues. Hard water contains high concentrations of minerals, primarily calcium (Ca²⁺) and magnesium (Mg²⁺) ions, which can lead to various problems, from limescale buildup in plumbing systems to dull laundry and dry skin. To mitigate these issues, many households turn to ion exchange water softeners. Removes organic matter from water, Pre-treatments for RO plant boiler feed and coling tower for chlorine removal from water, Flow Rate(max)- 40, resin- 2400litre, resin type- 440na, vessel 42*72, salt regenration- 176, output capacity fot recharge hardness- 308, |
| 480 | PDB CUM MCC PANEL |
| 481 | GST(18%) |
| 482 | Labour Cess (1%) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail