| 1 | BOQ FOR COMPLETE OVERHAULING /MAINTENANCE WORK OF 33 KV AND 11 KV VCB’S (PANELS BREAKERS COMPLETE UNIT) OF DIFFERENT MAKE INSTALLED AT VARIOUS S/S UNDER EDD, JWALAPUR, HARIDWAR IN O&M HEAD AGAINST E-TENDER NO- 26/EDC(H)/2026-27 Bidder's Name & Address S.N. Work Unit Qty. Rate Amount (In Rs.) |
| 2 | OVERHAULING/MAINTENANCE WORK OF 11 KV VCB AT 33/11 KV S/S JWALAPUR-II A Decentrlized Material |
| 3 | VACCUME INTERPTER FOR 11 KV VCB |
| 4 | MULTISTRAND PVC COPPER WIRE 2.5 SQMM |
| 5 | INDICATOR 110V DC |
| 6 | TRIPPING COIL 110V DC 11 KV |
| 7 | CLOSING COIL 110V DC 11 KV |
| 8 | IDMT RELAY Total (A) 0.0 B LABOUR |
| 9 | REPLACEMENT OF FEMALE CONTACT |
| 10 | COMPREHENSIVE TEST & CHECK OF WIRING |
| 11 | REPAIRING OF FEMALE CONTACT |
| 12 | REPAIRING OF MALE CONTACT |
| 13 | OVERHAULING OF 11 KV VCB'S MAIN PARTS |
| 14 | OVERHAULING MAINT. & ALIGN OF TROLLY ETC |
| 15 | REPAIRING OF TRIPPING SYSTEM ASSEMBLING |
| 16 | REPAIR OF GEARSET CHARGING OF MECHANISM |
| 17 | REPLACEMENT OF TULIP CONTACT |
| 18 | MAINTENANCE OF SPOUT |
| 19 | MAINTENANCE OF BUSBAR |
| 20 | REPLACEMENT OF INTERRUPTER HOUSING |
| 21 | REPAIRING OF GEAR ASSEMBLY |
| 22 | REPAIRING OF BUSHING Total (B) 0.0 |
| 23 | OVERHAULING/MAINTENANCE WORK OF DAMAGED 33 KV VCB'S AT 33/11 KV S/S JWALAPUR-II C Decentrlized Material |
| 24 | 33 KV BREAKER SPRING CHARGING MOTOR 220 V |
| 25 | MULTISTRAND PVC COPPER WIRE 2.5 SQMM |
| 26 | INDICATOR 110V DC |
| 27 | TRIPPING COIL 110V DC 11 KV |
| 28 | CLOSING COIL 110V DC 11 KV |
| 29 | IDMT RELAY Total (C) 0.0 D LABOUR |
| 30 | REPAIRING OF CONTROL PANEL 33 KV VCB |
| 31 | FILLING OF SF6 GAS IN 33 KV VCB |
| 32 | REPAIRING OF TRIPPING ASSEMBLY 33 KV VCB |
| 33 | REPLACEMENT OF CHARGING MOTOR 33 KV VCB |
| 34 | COMPREHENSIVE TEST & CHECK OF WIRING |
| 35 | COMPLETE TESTING WIRING |
| 36 | REPLACEMENT OF 33 KV RELAY FOR CTR PANEL |
| 37 | REPAIRING OF CONTROL PANEL ALINGMENT |
| 38 | REPAIR OF GEARSET CHARGING OF MECHANISM |
| 39 | REPAIRING OF GEAR ASSEMBLY |
| 40 | 33 KV BREAKER OVERHAULING & SETTING |
| 41 | PANNEL CLEAING AND PAINTING Total (D) 0.0 |
| 42 | OVERHAULING/MAINTENANCE WORK OF DAMAGED 11 KV VCB'S & PANELS AT 33/11 KV S/S SHADEVPUR E Decentrlized Material |
| 43 | VACCUME INTERPTER FOR 11 KV VCB |
| 44 | INDICATOR 110V DC |
| 45 | TRIPPING COIL 110V DC 11 KV |
| 46 | CLOSING COIL 110V DC 11 KV |
| 47 | COPPER WIRE 2.5 SQMM FR |
| 48 | IDMT RELAY Total (E) 0.0 F LABOUR |
| 49 | REPLACMENT SPOUT & VACCUME INTERRPUTER |
| 50 | REPLACEMENT OF FEMALE CONTACT |
| 51 | REPAIRING OF MALE CONTACT |
| 52 | COMPREHENSIVE TEST & CHECK OF WIRING |
| 53 | REPAIRING OF FEMALE CONTACT |
| 54 | REPAIRING OF MALE CONTACT |
| 55 | OVERHAULING OF 11 KV VCB'S MAIN PARTS |
| 56 | OVERHAULING MAINT. & ALIGN OF TROLLY ETC |
| 57 | REPAIRING OF TRIPPING SYSTEM ASSEMBLING |
| 58 | REPAIR OF GEARSET CHARGING OF MECHANISM |
| 59 | REPLACEMENT OF TULIP CONTACT |
| 60 | MAINTENANCE OF SPOUT |
| 61 | MAINTENANCE OF BUSBAR |
| 62 | REPLACEMENT OF INTERRUPTER HOUSING |
| 63 | REPAIRING OF GEAR ASSEMBLY |
| 64 | REPAIRING OF BUSHING Total (F) 0.0 |
| 65 | OVERHAULING/MAINTENANCE WORK OF 33 KV VCB'S & PANELS AT 33/11 KV S/S SHADEVPUR G Decentrlized Material |
| 66 | 33 KV BREAKER SPRING CHARGING MOTOR 220 V |
| 67 | VACCUME INTERPTER FOR BOTTLE FOR 33 KV VCB |
| 68 | INDICATOR 110V DC |
| 69 | TRIPPING COIL 110V DC 11 KV |
| 70 | CLOSING COIL 110V DC 11 KV |
| 71 | IDMT RELAY Total (G) 0.0 H LABOUR |
| 72 | REPAIRING OF CONTROL PANEL 33 KV VCB |
| 73 | REPAIRING OF TRIPPING ASSEMBLY 33 KV VCB |
| 74 | REPLACEMENT OF CHARGING MOTOR 33 KV VCB |
| 75 | COMPLETE TESTING WIRING |
| 76 | REPLACEMENT OF 33 KV RELAY FOR CTR PANEL |
| 77 | REPAIRING OF CONTROL PANEL ALINGMENT |
| 78 | REPAIR OF GEARSET CHARGING OF MECHANISM |
| 79 | REPAIRING OF GEAR ASSEMBLY |
| 80 | 33 KV BREAKER OVERHAULING & SETTING Total (H) 0.0 |
| 81 | COMPLETE OVERHAULING/MAINTENANCE WORK OF 11 KV VCB'S & PANELS AT 33/11 KV S/S TP NAGAR I Decentrlized Material |
| 82 | VACCUME INTERPTER FOR 11 KV VCB |
| 83 | INDICATOR 110V DC |
| 84 | TRIPPING COIL 110V DC 11 KV |
| 85 | CLOSING COIL 110V DC 11 KV |
| 86 | COPPER WIRE 2.5 SQMM FR |
| 87 | IDMT RELAY Total (I) 0.0 J LABOUR |
| 88 | REPLACMENT SPOUT & VACCUME INTERRPUTER |
| 89 | REPLACEMENT OF FEMALE CONTACT |
| 90 | REPAIRING OF MALE CONTACT |
| 91 | COMPREHENSIVE TEST & CHECK OF WIRING |
| 92 | REPAIRING OF FEMALE CONTACT |
| 93 | OVERHAULING OF 11 KV VCB'S MAIN PARTS |
| 94 | OVERHAULING MAINT. & ALIGN OF TROLLY ETC |
| 95 | REPAIRING OF TRIPPING SYSTEM ASSEMBLING |
| 96 | REPAIR OF GEARSET CHARGING OF MECHANISM |
| 97 | REPLACEMENT OF TULIP CONTACT |
| 98 | MAINTENANCE OF SPOUT |
| 99 | MAINTENANCE OF BUSBAR |
| 100 | REPLACEMENT OF INTERRUPTER HOUSING |
| 101 | REPAIRING OF GEAR ASSEMBLY |
| 102 | REPAIRING OF BUSHING Total (J) 0.0 Total (A+B+C+D+E+F+G+H+I+J) 0.0 Note :- GST will be paid extra as actuals. Company/Firm Name Name Designation Date |