| 1 | Providing all services for pumping arrangement to lift the water at jack well, Nandurbar including providing pump operator & Helper for operation of installed pumps , electrical panels of motors with its all accessories, minor repairs related to electric motor such as replacement of lugs etc. communicating with MSEDCL authorities in case of major failures to re-instate supply at the earliest etc. for 1 shifts daily including all labour etc. complete, at Jackwell (1 operator and 1 helper) Rate Excluding GST. |
| 2 | Providing all services for pumping arrangement to lift the water at WTP, Nandurbar including providing pump operator & Helper for operation of installed pumps , electrical panels of motors with its all accessories, minor repairs related to electric motor such as replacement of lugs etc. communicating with MSEDCL authorities in case of major failures to re-instate supply at the earliest etc. for 1 shifts daily including all labour etc. complete, at WTP (1 operator & 1 Helper) Rate Excluding GST |
| 3 | Providing all services for Maintenance works on Raw Water Rising Main and Pure water and distribution line system in the area, The petroling line work and the lines to check & stop the leakages also with all Including all related materials i.e welding machine ,pipeline cutter machine and man powers etc. complete. As and when Required. (2 Helpers & 1 Fitter) Rate Excluding GST. |
| 4 | Providing JCB for excavation during repairs of pipeline , leakage work as and when required. Providing JCB for excavation during repairs of pipeline. |
| 5 | Welding machine (Electric Transformer) Use for M.S. pipeline and other pipeline leakage works. |
| 6 | Electrician for electrical panels of motors with its all accessories, minor repairs related to electric motor such as replacement of lugs etc. communicating with MSEDCL authorities in case of major failures to re-instate supply at the earliest etc. |
| 7 | Providing and supplying I.S.I. mark rubber gasket suitable for C.I. or D. I. pipe of all class for tyton joints including inspection charges, transportation upto departmental stores excluding GST levied by GOI & GOM in all respect etc. complete. S.B.R. Gaskets for C. I. / D.I. Pipes 2) 100 mm |
| 8 | 3) 150 mm |
| 9 | 4) 200 mm |
| 10 | 6) 300 mm |
| 11 | 8) 400 mm |
| 12 | Supply of C. I . Mechanical Compression Collar Coupling suitable for C. I. Spun Pipes ( as per - IS - 1536 /2001) and complete with sealing rubber gasket of SBR,.C.I. follower Glands and M.S. nut Bolts. The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS:1538 /1993. 100 mm dia |
| 13 | 150 mm dia |
| 14 | 200 mm dia |
| 15 | 300 mm dia |
| 16 | 400 mm dia |
| 17 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valve - PN - 1.6 (Without by pass arrangement) 4) 100 mm. |
| 18 | 6) 150 mm. |
| 19 | 7) 200 mm. |
| 20 | Sluice valves - PN -1 (Without by pass) 3) 80 mm. |
| 21 | Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) (i) The Contractor at his request may be allowed to start construction of masonry steining so as not to allow silting of well in oncoming monsoon and while paying masonry, 25% amount shall be withheld and released only when excavation to the full depth is completed. (ii) Dewatering : Total dewatering charges are to be proposed in the tender as lumpsum amount and 75% is payable for excavation and 25% is payable for construction of well / gallery. Out of 75% excavation, break-up shall be as under 25% for last 1 M depth. 20% for 2 M depth which is just above last 1 M depth. 15% for 2 M depth which is just above last 3 M depth. 15% for the rest of depth from water table level. The above conditions will restrict the tendencies of agencies to avoid deepening of wells, etc. to the required depth. |
| 22 | Providing at departmental store or worksite fabricated M. S. Pipe and specials with socket and spigot ends for plain ends with necessary longitudinal and circumferential joints with required number of welding runs including cost of plates, welding rods & all kind of duties except octroi including loading unloading and transportation, etc. complete (Rates excluding GST) M. S. pipes & Specials of all sizes without plain ends |
| 23 | Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. Air Valve Single Ball Flanged / Screwed Type - PN -1.6 3) 25 mm. |
| 24 | Supply of C. I . Mechanical Joint Double Socket 900 (11/4’’) Bends as dimensionally described in Table-14 of IS-13382/ 1992 complete with sealing rubber gasket of SBR (dimensionally described in IS-12820/1989) with cast iron follower gland and mild steel nut bolts coated or otherwise protected from rusting and suitable for C. I. pipes. 80 mm dia |
| 25 | Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete. Kinetic Air Valve Flanged Type - PN -1.6 1) 40 mm. |
| 26 | D.I. Socket and flanged fittings :-Providing and supplying D.I. fitting with I SI mark socket pushon joints or flanged joints confirming to table 12 to 31 of IS 9523/2000 upto latest amendments including cost of SBR/ EDPM tyton rings. Fittings should be with internally ordinary portland cement mortor lined and externally metallic zinc coating/zinc rich paint with finishing layer of black bitumen coating including transportation & excluding all statutary duties and taxes such as GST levied by Gol and GoM in all respect etc. complete. Diameter in mm All Flange Tee -PN-10 1) 80 x 80 mm dia |
| 27 | 3) 100 x 100 mm dia |
| 28 | 4) 150 x 80 mm dia |
| 29 | 5) 150 x 100 mm dia |
| 30 | 8) 200 x 100 mm dia |
| 31 | 10) 200 x 200 mm dia |
| 32 | 15) 250 x 250 mm dia |
| 33 | 21) 300 x 300 mm dia |
| 34 | 6) 150 x 150 mm dia |
| 35 | Double socket concentric reducer 3) 150 x 100 mm dia |
| 36 | 5) 200 x 100 mm dia |
| 37 | 6) 200 x 150 mm dia |
| 38 | 10) 250 x 200 mm dia |
| 39 | 12) 300 x 150 mm dia |
| 40 | 13) 300 x 200 mm dia |
| 41 | 14) 300 x 250 mm dia |
| 42 | Double Flange Bend 90 Deg -PN-‘10 2) 100 mm dia |
| 43 | 3) 150 mm dia |
| 44 | 4) 200 mm dia |
| 45 | Double Socket Tee with Flange branch-PN-10 2) 100 x 80 mm dia |
| 46 | 3) 100 x 100 mm dia |
| 47 | 4) 150 x 80 mm dia |
| 48 | 6) 150 x 150 mm dia |
| 49 | 7) 200 x 80 mm dia |
| 50 | 9) 200 x 150 mm dia |
| 51 | 10) 200 x 200 mm dia |
| 52 | 11) 250 x 80 mm dia |
| 53 | 16) 300 x 80 mm dia |
| 54 | 21) 300 x 300 mm dia |
| 55 | Providing and supplying D.I. fittings with I SI mark Mechanical j oint confirming to tables 12 to table 31 of IS 9523/2000 upto latest amendments including cost of SBR/ EDPM gaskets, Nuts, Bolts, Washers and Ductile iron follower glands. Fittings should be with internally Ordinary portland cement mortor lined and externally metallic zinc coating/zinc rich paint with finishing layer of black bitumen coating including transportation and excluding all statutary duties and taxes such as GST levied by Gol and GoM in all respect etc. complete. D.I. FITTINGS (Mechanical Joints) MJ Collar/Coupling 1) 80 mm dia |
| 56 | 2) 100 mm dia |
| 57 | 3) 150 mm dia |
| 58 | 4) 200 mm dia |
| 59 | 5) 250 mm dia |
| 60 | 6) 300 mm dia |
| 61 | 8) 400 mm dia Please Enable Macros to View BoQ information |