| 1 | Dismanteling of old CC flooring / Dismantling Brick/Tile Work Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(1:2:4) cement,C/sand& 20mm S/gritt I/C all comp. |
| 2 | Excavation in foundation in ordinary soil (Loam clay, or sand) including lift upto 1.50 mts and lead upto 30 m. & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches. |
| 3 | Concrete with 4 cm. gauge STONE ballast, C/sand of 1.25 finess modulous and cement in proportion of 10:5:1 in foundations and floors including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 4 | First class brick work in 1:6 cement and F/ sand of 1.25 F.M. mortar in foundation and plinth including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 5 | M-150 Class B/W (1:4) cement C/sandMortor in foundation up to plinth SI-303 |
| 6 | First class brick work in 1:6 cement and F/sand of 1.25 F.M. mortar in superstructure including necessary cutting & moulding of brick as required thickness of walls of one brick thick, including supply of all materials labour and T & P etc. required for proper completion of work. |
| 7 | R.C.C. work with cement, approved coarse sand and 2 cm. gauge approved stone ballast in proportion of 1:1.50:3 in lintels of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire, and including necessary centering and shuttering etc. and also including supply of all materials, T&P etc.required for proper completion of work. |
| 8 | Centering and shuttering I/c strutting propping etc and removal of form for Roof slab./DSRV-1/5.9.3/=927.25*0.757=701.928 |
| 9 | R.C.C. work with cement, approved coarse sand and 2 cm. gauge approved stone ballast in proportion of 1:1.5:3 for slabs and excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire, and including necessary centering and shuttering etc. and also including supply of all materials, T & P etc. required for proper completion of work. |
| 10 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick work ( when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & over lapping and hooks. |
| 11 | 12mm thick plaster with one part of cement and six part of approved fine sand over brick work minimum thickness not to be less than 1Cm. Including supply of all materials labour and T&P etc. required for proper completion of the work. Add. for extra labour & materials for plaster , over rough face of one brick wall ROUGHT FACE INDISE |
| 12 | 12mm thick plaster with one part of cement and six part of approved fine sand over brick work minimum thickness not to be less than 1Cm. Including supply of all materials labour and T&P etc. required for proper completion of the work. Add. for extra labour & materials for plaster , over rough face of one brick wall OUT SIDE |
| 13 | 12mm thick monolithic cement plaster of mix 1:3 with cement &c/sand with a floating coat of neat cement as per DSR-2023-13.9.1 |
| 14 | Earth work in cutting or in embankment in ordinary soil excavation to be in the from of regular pits including ramming dressing & watering for the surface to required level & slop 1.50 mt left & 30mt lead all cost of complete & with extra lead 5.00 km Cartage including loading unloading etc. |
| 15 | Plain cement concrete floor 4.0 cm. (1.5\\") thick in 1:2:4 cement, approved coarse sand and 2 cm. (3/4\\") graded approved stone laid in panels finished with 3 mm. (1/8\\") flooring coat of neat cement or cement and marble dust in 5:1 as specified without base cocrete including removing any overlapping mortor at the joints of panels if any and giving them a uniform finish including supply of all material, labour and T&P etc. required for proper completion of work.with base concrete 3 inch th. in 1:4:8 cement, F/ sand and 40mm. B/Ballest. |
| 16 | Providing & fixing glass strips of 3.15 mm (1/8\\") thickness. and 3.70 mm depth in joints of floor and skirting at time of laying floors, flash with floor level, including labour and T&P etc. |
| 17 | 2 cm. Th. Cement plaster in Dado/skirting in 1:2 cement,C/sand mortar laid in panals finished with 3mm. Floating coat of neat cement and marble dust in ratio 5:1 including all cast of complet. |
| 18 | M.S. or iron work of small sizes and section such as holding down bolts hold fast tierods grating etc. wrought to required from including supply of steal bolts nuts wastage etc.and their fixing requireded for proper complition of work.but of fabrication of door & window frame excluding cost of hinges to be issued departmentally free of cost. Angles 40 x 40 x 5 mm.OR M.S.Work in heavy size such as gali grill window etc door window I/Call com.S.No.517a./=5804.35*0.757=4393.892 |
| 19 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approved superior quality ready mixed paint or varnish including supply of all material, Tools, & plants etc. required for proper completion of the work. Paint to be used ISI marked.OR Two coat of painting over one primer coat I/C all com.S.I.No.644+645/DSRV-II/CodeNo.13.48.3/=170.70*0.757=129.219 |
| 20 | distempering with oil bound distemper of approved and required shade on undercorted wall surface to give an even shade over and including a priming coat with cement primer of approved brand as shalimar ,Asian paint after through brushing the surface free from mortar dropping and other forigoen matters and also including the surface even with POP including of all material labour, Tool & plant etc. required for proper completion of work. As per S.I .no 649+650.ORTwo coat of Distemper over one primer coat I/C all com.S.I.No.649+650/DSRV-II/CodeNo.13.41.1/=185.65*0.757=140.537 |
| 21 | Finishing walls with superion quality water proof cement paint/snoweem of approved make and quality on new work with three coats to give even shade, including preparing surface by the thoughtly cleaning and sand preparing and supply of all materials, labour and T&P etc. required for proper completion of the work.but for each after the first two coats two give and even shade.OR Three coat of Water proof snowcm painting I/c all com.S.I.No.660+661/DSRV-II/CodeNo.13.44.1/=116.9*0.757=88.4933 |
| 22 | P.C.C with 2 Cm. gauge stone grit (Crushed) approved coarse sand and cement in proportion of 4:2:1 including supply of all materials labour and T&P etc. required for proper completion of work. |
| 23 | Providing & fixing of fly proof wire gauze to windows,clerestory window & doors with M.S.Flat 15x3mm and nuts &bolts complete. 10.29.1.Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4mmaperture on both sides i/c all complete materials labour and T&P S.I.No. DSR V-I/Code No.10.29.1=844.70*0.757=639.44 |
| 24 | Providing and fixing water closet squatting pan (Inglo Indian type W.C. PAN) with 100 mm sand cast iron P or S trap, 10 lit low level white P.V.C. flushing cistren including flush pipe with mannuly controlled device 580x440mm. DSR Ref. 17.1.1 |
| 25 | Providing and fixing white vitreous china pedestal type water closet squatting pan (Inglo European type W.C. PAN) with seat and lid , 100 mm sand cast iron P or S trap, 10 lit low level white P.V.C. flushing cistren including flush pipe with mannuly controlled device 580x440mm. DSR Ref. 17.3.1 |
| 26 | Providing and fixing white vitreous china squatting plate urinal with integral rim longtudinal flush pipe.OR flat back or wall corner type lipped front urinal basin of 430x260x350 mim and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, Indluding painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern. as per DSR. 2023 S.I. No.-17.24.. |
| 27 | Provinding and fixing white vitreous china wash basin 550X400mm with 15 mm C.P. brass pillar tap including 12% GST DSR. 17.7.3 |
| 28 | Providing and fixing Chlorinated Polyvinyl chloride (C.P.V.C.) pipes having thermal stability for hot and cold water supply, including all C.P.V.C. plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer Incharge exposed on walls DSR Ref. 18.7.1 (1) 15.00 mm nomintl outer dia |
| 29 | Providing and fixing Chlorinated Polyvinyl chloride (C.P.V.C.) pipes having thermal stability for hot and cold water supply, including all C.P.V.C. plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer Incharge exposed on walls DSR Ref. 18.7.2 SIN (1) 20.00 mm nomintl outer dia |
| 30 | Providing and fixing Chlorinated Polyvinyl chloride (C.P.V.C.) pipes having thermal stability for hot and cold water supply, including all C.P.V.C. plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and th cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer Incharge exposed on walls DSR Ref. 18.8.2 SIN (1) 20.00 mm nomintl outer dia |
| 31 | Providing and fixing Chlorinated Polyvinyl chloride (C.P.V.C.) pipes having thermal stability for hot and cold water supply, including all C.P.V.C. plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer Incharge DSR Ref. 18.9.9 (9) 100.00 mm nomintl outer dia. |
| 32 | Supply of 20 mm dia Gate wall As per Lko SOR. as per Chap-21- SI No.66 |
| 33 | Supply of C.P. Bib cock heavy quality (Gem Mikadeo/Encess's willams or eqy 15 mm dia 400 gms)As per SOR. as per .Chap-21- SI No.51 |
| 34 | Supply of Brass stop cock As per LKO .as per Chap-21- SI No.45 |
| 35 | Supply of PVC Conaction 450 mm Long with two brass unit As per SOR as per .Chap-21- SI No.96 |
| 36 | Supply of PVC Waste Pipe 32 mm As per LKO SOR. as per .Chap-21- SI No.95 |
| 37 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet outlet and over flow pipes but without fittings and base support for tank DSR 18.48 |
| 38 | Supply & Fixing of name sign board at site i/c all materials complete As per Direction of engineer incharge . . |
| 39 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. as per DSR(E&M)-2022 Sl no.1.10.1 Group-A |
| 40 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.as per DSR(E&M)-2022 Sl no.1.12 |
| 41 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.as per DSR(E&M)-2022 Sl no.1.31 |
| 42 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.as per DSR(E&M)-2022 Sl no.1.32 |
| 43 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.as per DSR(E&M)-2022 Sl no.1.25 |
| 44 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.as per DSR(E&M)-2022 Sl no.2.10.1 Single pole |
| 45 | Supply and fixing of 12-15 Watt LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt) Supplying, installation, testing &Commissioning of LED Recessed/surface Down lighter (Round /squre/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement. Powder coated dia cast /Extruded aluminium Body including trim. complete all as per DSR E&M 8.3.3 |
| 46 | Supply and fixing of Bruh Less Direct Current (BLDC) mortar supply, Installation, Testing and Commissioning of celling fan with Brush Less Direct Current (BLDC) mortar, class of insulation: B, 3 nos.metal (Aluminum alloy) blades, 30 cm long down rod 2 nos. cogylator nopies, complete all as per DSR E&M 9.2.2 |
| 47 | Less 5% Competitive price efficeincy Please Enable Macros to View BoQ information |