| 1 | The work of Installation Additional 63/100 KVA Distribution Transformer with Extension of LT Line and LT Line Augmentation i.e. replacement of damaged AB Cable in LT Line at selected 05+25+01 Nos. places under BUSINESS PLAN SCHEME 2026-27 under EUDD, BANDA/EDD, BANDA/ATARRA, including carriage of all required material/Transformers from ESC/Workshop BANDA to work site, alongwith its loading, unloading & dragging at the respective ends and also carriage of old/dismentled line material/T/Fs from site to store centre/workshop, if any. The bidder shall be responsible for complete execution of the work under the scope of tender specification. Any work/activity not specifically indicated but is required for systematic execution of job shall be carried out by the contractor without any extra payment. The material supplied by contractor should be the best quality and as per standard including transportation, if any. Details of the work as given below ;- | The work of Installation Additional 63/100 KVA Distribution Transformer with Extension of LT Line and LT Line Augmentation i.e. replacement of damaged AB Cable in LT Line at selected 05+25+01 Nos. places under BUSINESS PLAN SCHEME 2026-27 under EUDD, BANDA/EDD, BANDA/ATARRA, including carriage of all required material/Transformers from ESC/Workshop BANDA to work site, alongwith its loading, unloading & dragging at the respective ends and also carriage of old/dismentled line material/T/Fs from site to store centre/workshop, if any. The bidder shall be responsible for complete execution of the work under the scope of tender specification. Any work/activity not specifically indicated but is required for systematic execution of job shall be carried out by the contractor without any extra payment. The material supplied by contractor should be the best quality and as per standard including transportation, if any. Details of the work as given below ;- |
| 2 | Supply of following materials :- | Supply of following materials :- |
| 3 | MS Dropper Channel 100x50x2028 mm. as per RESSPO manual. | MS Dropper Channel 100x50x2028 mm. as per RESSPO manual. |
| 4 | Clamps for LT T-off with bolts & nuts as per RESSPO manual. | Clamps for LT T-off with bolts & nuts as per RESSPO manual. |
| 5 | Holding Clamp for top channel, TPMO & fuse set etc. with bolt-nuts as per RESSPO manual. | Holding Clamp for top channel, TPMO & fuse set etc. with bolt-nuts as per RESSPO manual. |
| 6 | MS Angle 75x75x6x2028 mm. with clamp & bolt-nuts (T/F Base) as per RESSPO manual. | MS Angle 75x75x6x2028 mm. with clamp & bolt-nuts (T/F Base) as per RESSPO manual. |
| 7 | MS Top Channel (125x65x2240 mm) as per RESSPO manual. | MS Top Channel (125x65x2240 mm) as per RESSPO manual. |
| 8 | MS T-off Channel (125x65x1300 mm) as per RESSPO manual. | MS T-off Channel (125x65x1300 mm) as per RESSPO manual. |
| 9 | PRC as per RESSPO manual. | PRC as per RESSPO manual. |
| 10 | Suspension Clamp as per RESSPO manual. | Suspension Clamp as per RESSPO manual. |
| 11 | Dead End Clamp as per RESSPO manual. | Dead End Clamp as per RESSPO manual. |
| 12 | I-Hook as per RESSPO manual. | I-Hook as per RESSPO manual. |
| 13 | J-Hook as per RESSPO manual. | J-Hook as per RESSPO manual. |
| 14 | Barbed wire for jumper as per RESSPO manual. | Barbed wire for jumper as per RESSPO manual. |
| 15 | 11 KV Danger Board with clamp as per RESSPO manual. | 11 KV Danger Board with clamp as per RESSPO manual. |
| 16 | Nut-Bolts of suitable size as per RESSPO manual. | Nut-Bolts of suitable size as per RESSPO manual. |
| 17 | Erection/Instalation/Fixing of following :- | Erection/Instalation/Fixing of following :- |
| 18 | Safe cartage of 8.5 Mtr. long PCC poles from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging. | Safe cartage of 8.5 Mtr. long PCC poles from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging. |
| 19 | Safe cartage of line material viz. conductor, cable, G.I. earth wire, cross arm, angle, channel, insulator, clamps and other line material from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, including the work of its dragging. | Safe cartage of line material viz. conductor, cable, G.I. earth wire, cross arm, angle, channel, insulator, clamps and other line material from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, including the work of its dragging. |
| 20 | Erection of Single support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. | Erection of Single support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. |
| 21 | Grouting of Single support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each). | Grouting of Single support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each). |
| 22 | Erection of Double support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. | Erection of Double support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. |
| 23 | Grouting of Double support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each). | Grouting of Double support on 8.5 Mtr. long PCC poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each). |
| 24 | Erection and grouting of stay set with nozelling & binding as per norms. | Erection and grouting of stay set with nozelling & binding as per norms. |
| 25 | Fixing of earthing rod as per RESSPO manual. | Fixing of earthing rod as per RESSPO manual. |
| 26 | Laying, stringing, binding and termination etc. LT PVC Cable of size on the newly erected D/P as per direction of supervising engineer/RESSPO manual. | Laying, stringing, binding and termination etc. LT PVC Cable of size on the newly erected D/P as per direction of supervising engineer/RESSPO manual. |
| 27 | Laying, stringing, binding and termination etc. of LT ABC Cable of size (3*50+1*35+1*16/3*95+1*70+1*16) Sq.mm. on the newly erected line as per direction of supervising engineer/RESSPO manual. | Laying, stringing, binding and termination etc. of LT ABC Cable of size (3*50+1*35+1*16/3*95+1*70+1*16) Sq.mm. on the newly erected line as per direction of supervising engineer/RESSPO manual. |
| 28 | Safe cartage of 63 KVA Transformers from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, including the work of dragging and safely installation/erection/commisioning of 63 KVA Transformers on the newly/old erected doube pole structure in proper alignment and as per direction of supervising engineer/RESSPO manual. | Safe cartage of 63 KVA Transformers from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, including the work of dragging and safely installation/erection/commisioning of 63 KVA Transformers on the newly/old erected doube pole structure in proper alignment and as per direction of supervising engineer/RESSPO manual. |
| 29 | Safe cartage of 100 KVA Transformers from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, including the work of dragging and safely Installation/Erection/Commisioning of 100 KVA Transformers on the newly/old erected doube pole structure in proper alignment and as per direction of supervising engineer/RESSPO manual. | Safe cartage of 100 KVA Transformers from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, including the work of dragging and safely Installation/Erection/Commisioning of 100 KVA Transformers on the newly/old erected doube pole structure in proper alignment and as per direction of supervising engineer/RESSPO manual. |
| 30 | Fixing of Distribution Box with fitting of all accessories as per RESSPO manual. | Fixing of Distribution Box with fitting of all accessories as per RESSPO manual. |
| 31 | Fixing of T-Off Channel with fitting of all accessories as per RESSPO manual. | Fixing of T-Off Channel with fitting of all accessories as per RESSPO manual. |
| 32 | Fixing of 11 KV Fuse set with fitting of all accessories as per RESSPO manual. | Fixing of 11 KV Fuse set with fitting of all accessories as per RESSPO manual. |
| 33 | Fixing of 11 KV TPMO with fitting of all accessories as per RESSPO manual. | Fixing of 11 KV TPMO with fitting of all accessories as per RESSPO manual. |
| 34 | Fixing of 11 KV Danger Board with fitting of all accessories as per RESSPO manual. | Fixing of 11 KV Danger Board with fitting of all accessories as per RESSPO manual. |
| 35 | Straightening of tilted support as PCC/ST Pole at various places | Straightening of tilted support as PCC/ST Pole at various places |
| 36 | Resagging of loose conductor of 11 KV/LT Lines at various places. | Resagging of loose conductor of 11 KV/LT Lines at various places. |
| 37 | Note: Any quantity of item from sl no. 1 to sl no. 2.19 may vary to any limit within the financial value of agreement against this tender. | Note: Any quantity of item from sl no. 1 to sl no. 2.19 may vary to any limit within the financial value of agreement against this tender. |