| 1 | (Part-A) Supply & Erection Providing & Fixing of Top Channel | (Part-A) Supply & Erection Providing & Fixing of Top Channel |
| 2 | Providing & Fixing of Stone pad | Providing & Fixing of Stone pad |
| 3 | Providing & Fixing of Clamp for 33kv X Arm | Providing & Fixing of Clamp for 33kv X Arm |
| 4 | Providing & Fixing of F Clamp | Providing & Fixing of F Clamp |
| 5 | Providing & Fixing of MS Angle | Providing & Fixing of MS Angle |
| 6 | Providing & Fixing of HDPE Pipe | Providing & Fixing of HDPE Pipe |
| 7 | Providing & Fixing of PG Clamp | Providing & Fixing of PG Clamp |
| 8 | Providing & Fixing of 33 kv Top channel | Providing & Fixing of 33 kv Top channel |
| 9 | Providing & Fixing of Shakel Insulator | Providing & Fixing of Shakel Insulator |
| 10 | Providing & Fixing of 33 kv F Bracket | Providing & Fixing of 33 kv F Bracket |
| 11 | Providing & Fixing of T- Channel with clamp | Providing & Fixing of T- Channel with clamp |
| 12 | Providing & Fixing of LT Clamp | Providing & Fixing of LT Clamp |
| 13 | Providing & Fixing of Number Plate | Providing & Fixing of Number Plate |
| 14 | Providing & Fixing of Gaurding clamp | Providing & Fixing of Gaurding clamp |
| 15 | Providing & Fixing of Gaurding Angle | Providing & Fixing of Gaurding Angle |
| 16 | (Part-B) Carriage & Erection Carriage of PCC Pole 8.5 Mtr. Long. from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) | (Part-B) Carriage & Erection Carriage of PCC Pole 8.5 Mtr. Long. from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) |
| 17 | Carriage of PCC Pole 9 Mtr. Long. from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) | Carriage of PCC Pole 9 Mtr. Long. from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) |
| 18 | Carriage of ST Pole 11/13 Mtr. Long. from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) | Carriage of ST Pole 11/13 Mtr. Long. from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) |
| 19 | Carriage of 63 KVA T/F fromElectricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) | Carriage of 63 KVA T/F fromElectricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) |
| 20 | Cartiage of 33kv XLPE CABLE 3*300 SQMM (460 mtr), 11kv XLPE Cable 3x185sqmm (280mtr), LT XLPE Cable, 11kv XLPE Cable 3x300sqmm (150 mtr) 3.5*70sqmm (280 mtr) from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.) | Cartiage of 33kv XLPE CABLE 3*300 SQMM (460 mtr), 11kv XLPE Cable 3x185sqmm (280mtr), LT XLPE Cable, 11kv XLPE Cable 3x300sqmm (150 mtr) 3.5*70sqmm (280 mtr) from Electricity Store CentreTajganj Agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.) |
| 21 | Carriage of following material from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50 Kms.) J) 11kv disc Insulator with pin (814), 33kv disc Insulator with fiting (15), 11kv Pin Insulator with pin (4762), 33kv Pin Insulator with pin (84), Stay Set (313), Earthing Complete (1446), Weasal Conductor (44270 mtr), Rabbit Conductor (1360 mtr), Dog Consuctor (350 mtr),, 11kv Jointing Kit 3x185sqmm (4), , 11kv Jointing Kit 3.5*70sqmm (4), , Jointing Kit 3x300sqmm (4), Gaurding Wire (164 kg), 33kv jointing kit 3*300sqmm (4) | Carriage of following material from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50 Kms.) J) 11kv disc Insulator with pin (814), 33kv disc Insulator with fiting (15), 11kv Pin Insulator with pin (4762), 33kv Pin Insulator with pin (84), Stay Set (313), Earthing Complete (1446), Weasal Conductor (44270 mtr), Rabbit Conductor (1360 mtr), Dog Consuctor (350 mtr),, 11kv Jointing Kit 3x185sqmm (4), , 11kv Jointing Kit 3.5*70sqmm (4), , Jointing Kit 3x300sqmm (4), Gaurding Wire (164 kg), 33kv jointing kit 3*300sqmm (4) |
| 22 | Erection and grouting of Single Pole 8.5 Mtr. long PCC poles in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. | Erection and grouting of Single Pole 8.5 Mtr. long PCC poles in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. |
| 23 | Erection and grouting of Double Pole 8.5 Mtr. long PCC Pole in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. | Erection and grouting of Double Pole 8.5 Mtr. long PCC Pole in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. |
| 24 | Erection and grouting of Double Pole 9 Mtr. long PCC Pole in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. | Erection and grouting of Double Pole 9 Mtr. long PCC Pole in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. |
| 25 | Erection and grouting of ST Pole 11/13 Mtr. long Single in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms.Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. | Erection and grouting of ST Pole 11/13 Mtr. long Single in 1:2:4 ratio (cement, sand and bricks balast) including fixing of all accessories alongwith stone pad as per RESPO norms.Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost. |
| 26 | Mounting & Installation of 63 KVA T/F on Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work. | Mounting & Installation of 63 KVA T/F on Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work. |
| 27 | Laying of LT XLPE Alu. Cable 1x400 sqmm as per RESPO Norms and direction by superivising Engineer. | Laying of LT XLPE Alu. Cable 1x400 sqmm as per RESPO Norms and direction by superivising Engineer. |
| 28 | Fixing of earthing Complete as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. | Fixing of earthing Complete as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. |
| 29 | Laying, sagging, stringing, binding and jumpering of ACSR Weasal conductor/ Dog Conductor/ Rabbit Conductor in 33/11kv line as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc reauired for proper completion of work. | Laying, sagging, stringing, binding and jumpering of ACSR Weasal conductor/ Dog Conductor/ Rabbit Conductor in 33/11kv line as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc reauired for proper completion of work. |
| 30 | Laying of 33 KV XLPE cable 3x300 sqmm Through H.D.P.E.pipe by drill machine/H.D.D. Machine including the cost of arrangment of labour, T&P & Drill machine/H.D.D. machine at a depth as per Railway Norms. Below the Railway Crossing. | Laying of 33 KV XLPE cable 3x300 sqmm Through H.D.P.E.pipe by drill machine/H.D.D. Machine including the cost of arrangment of labour, T&P & Drill machine/H.D.D. machine at a depth as per Railway Norms. Below the Railway Crossing. |
| 31 | Laying of LT XLPE Cable 3.5x70 sqmm overhead with making loop as per RESPO Norms and direction by superivising Engineer. | Laying of LT XLPE Cable 3.5x70 sqmm overhead with making loop as per RESPO Norms and direction by superivising Engineer. |
| 32 | Concreting of Stay erection complete in all respect as direction by supervising Engineer. All required Material Provided by Contractor at his own cost | Concreting of Stay erection complete in all respect as direction by supervising Engineer. All required Material Provided by Contractor at his own cost |
| 33 | Laying of 33 KV XLPE Cable 3x300 sqmm through GI Pipe and Mounting on Double Pole as per RESPO Norms and direction by superivising Engineer. | Laying of 33 KV XLPE Cable 3x300 sqmm through GI Pipe and Mounting on Double Pole as per RESPO Norms and direction by superivising Engineer. |
| 34 | Laying of 11 KV XLPE cable 3x185 sqmm/3x300sqmm Through H.D.P.E.pipe by drill machine/H.D.D. Machine including the cost of arrangment of labour, T&P & Drill machine/H.D.D. machine at a depth as per Railway Norms. Below the Railway Crossing. | Laying of 11 KV XLPE cable 3x185 sqmm/3x300sqmm Through H.D.P.E.pipe by drill machine/H.D.D. Machine including the cost of arrangment of labour, T&P & Drill machine/H.D.D. machine at a depth as per Railway Norms. Below the Railway Crossing. |
| 35 | Filling of 11 KV Jointing Kit 3x300/ 3x185/ 3.5x70 sqmm OD/ID and making connection as per direction by supervising engineer. | Filling of 11 KV Jointing Kit 3x300/ 3x185/ 3.5x70 sqmm OD/ID and making connection as per direction by supervising engineer. |
| 36 | Filling of 33 KV Jointing Kit 3x300 sqmm OD/ID and making connection as per direction by supervising engineer. | Filling of 33 KV Jointing Kit 3x300 sqmm OD/ID and making connection as per direction by supervising engineer. |
| 37 | Installation of Stay set Complete as direction by supervising Engineer. | Installation of Stay set Complete as direction by supervising Engineer. |
| 38 | Erection of Gaurding below 33/11kv overhead line using 6 SWG GI wire complete with Gaurding Engle clamps nut & Bolt binding and all necessary complete in all respects as per RESPO norms | Erection of Gaurding below 33/11kv overhead line using 6 SWG GI wire complete with Gaurding Engle clamps nut & Bolt binding and all necessary complete in all respects as per RESPO norms |
| 39 | Dismentling, Removal of Old & used Scrap Material and received back to ele. Store center Taj Agra including Loading, unloading both ends (0-50km) | Dismentling, Removal of Old & used Scrap Material and received back to ele. Store center Taj Agra including Loading, unloading both ends (0-50km) |