| 1 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 2 | 1.14.2Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | 1.14.7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 4 | 1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm |
| 5 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm |
| 6 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 7 | 1.47Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10cm & 5cm or less shall be ignored) |
| 8 | 2.16Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts 'C' curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 9 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 10 | 1.44Installation, testing and commissioning of ceiling fan, including wiring the down rods (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 11 | OD197199/2025-2026Labour charge for removing the ceiling fan and installing this same at new location etc on the existing fan hook |
| 12 | OD198027/2025-2026Supply and laying 16/0.20 mm 3 core round copper conductor flex wire |
| 13 | OD199598/2025-2026Cost for dismantling 6 module GI box with modular plate including 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switches and installing to new location without any damage |
| 14 | OD200377/2025-2026Labour charges for dismantling existing circuit points and clamping of the existing pipe |
| 15 | OD262763/2025-2026Labour charge for installation of 22W to 25W LED recess mount down light including connections etc completed Please Enable Macros to View BoQ information |