| 1 | Material & Labour for carring to work shop U/S submersible & monoblock motor (water cooled or oil cooled) & pump including cutting U/S winding , removing insulating material, cleaning and rewinding with PVC insulated 1100 volts grade single core copper conductor as per IS 694 winding wire of appropriate size/gauge as per existing , providing insulting mterial of superior quality , supply & replace thrust bearing , assembling the motor complete , including coupling with multistage pump , jointing & connecting with submersible cable and testing at site for following HP of any make : |
| 2 | 2.00 HP to 5 HP |
| 3 | 7.5 HP to 10 HP |
| 4 | 12.50/15.00 HP |
| 5 | Taking out of submersible pump set from borewell/ Openwell/ sump and servicing of pump set upto 15 HP by replacing of wear & tear parts/rewinding and relowering , including necessary electric and water connections, testing all as specified and directed |
| 6 | Taking down and dismantling of mono block centrifugal pump set of capacity 7.5 HP to 10.0 HP including impeller and over hauling, supply and fixing of bearing, impeller as per specification, gland bush, stuffing box, gland nuts, gland rope, terminal plate , oiling/greasing and change of gasket/ joints, two coats of synthetic enamal paint, refixing terminal connections , lugs and testing complete on full load after refixing of pipe lines complete all as specified and directed. |
| 7 | Cleaning of UG (under ground) sumps incl scraping of walls, bottom and mouth of circulating pipe (incoming, outgoing, interconnecting and overflow pipes) and removing the accumulated dirt in form of mud & deposited salts on bottom & walls sump by manullay/mechanically & cleaning the sump by fresh water and finally giving single coat of cement wash on inner surface of the walls & bottom of the sump and painting /writing of date of cleaning all as directed by Engr-in-Charge for the following capacities of sumps :- |
| 8 | UG sump 15000 Gallons capacity at Main Pump House |
| 9 | UG sump 50000 Gallons capacity at Main Pump House |
| 10 | UG sump 5000 Gallons capacity at Booster pump No -3 |
| 11 | UG sump 3000 Gallons capacity at Booster pump No -3 |
| 12 | UG sump 20000 Gallons capacity Near SL-89 |
| 13 | UG sump 40000 Gallons capacity at Booster pump No- 6 |
| 14 | UG sump 7000 Gallons capacity at JCO's pump house |
| 15 | UG sump 3000 Gallons capacity at Mount pleasant pump house |
| 16 | UG sump 2000 Gallons capacity at Mount pleasant pump house |
| 17 | Supply, laying and connecting submersible cable water proof flat 3 core copper conductor PVC insulated & PVC sheathed 1100 Volts grade 6 Sqmm as per IS-694 for subemrsible pumps. |
| 18 | Repair of pump motor starter of any type & capacity by decarbonizes of contact point, tightening of electric cables and replacement of unserviceable part and complete testing after repair as directed. |
| 19 | Taking down unserviceable water pressure gauge with rusted and incrustation GI Nipple and supply and fix water pressure gauge dialed type, having scale 0-10 Kg/cm with 15mm x 30 cm long GI Nipple complete fixed to delivery pipe all as specifed and directed. |
| 20 | Taking up or down foot valve, removing from site and Suppy, fixing and installed foot valve 80mm (3\\") dia foot valve confirming to IS 4038 with brass spindle and using plate flanged and drilled incl necessary nut bolts and washers complete. |
| 21 | Supply only O-TOLIDINE reagent solution in 500 ml bottle |
| 22 | Supply only sodium hypochlorite solution 90 to 120 GPL in PVC container of 40 ltrs capacity. |
| 23 | Repairs of water supply installation electric panels by checking electric connections & replace unsv lugs with new lugs, copper wire etc and testing & replacement of following items:- |
| 24 | 3 Phase selector switch |
| 25 | 3 phase indicator lamp (RYB) |
| 26 | Replace existing Volt Meter with digital voltmeter for 3 |
| 27 | Replace existing 3phase Amp meter with digital Amp meter |
| 28 | Material & Labour for taking out unservisable submersible pumpset(alogwith submersible motor)of any capacity & make,including delivery pipe 40/50 mm bore,flanged/Socket GI tubing (Average 3/6 meter long each pipe), from borewell depth Upto 150 meters, and including lowering the same after repairs of pumpset all as directed by Engr-in-Charge. Note:- (i) Rates are deemed for making flanged/MS Socket joints with rubber washers and replacement of rusted nuts,bolts in work etc all as directed by Engineer-in-charge. |
| 29 | Material and Labour for Testing of water from approved Govt lab samples collected from pump house No No-01 at main Gate and Pump House No-05 and Pump House Near SL-89 as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge Each Month throughout the Contract Period. |
| 30 | Supply and fixing MUg-10 DOL starter with MS sheet( 2 mm Thick) enclosure suitable for - 15 HP Monoblock Pump motor in existing location including making connection with PVC insulated 1100 volts grade ,three core , multistranded copper conductor of size 6.0 sq mm with voltmeter,ampere meter, Auto Switch,Single Phase Preventor & Indicating Lamp Led Type for Phase Indication (Red Yellow & Blue) ,all as directed and specified. Make : L&T/Havells/Siemens |
| 31 | Supply and fix ON LOAD change overswitch 415V in sheet metal enclosures 4 pole of capacity 160 Amps complete all as specified and directed by Engr-in-Charge. |
| 32 | Excavation in trenches n exc 1.5m wide and n exc 1.5 m depth and getting out in any type of soil complete all as specified |
| 33 | Returning filling in incl spreading, leveling in layers n.exc 25 cm in any type of soil complete all as directed |
| 34 | Removing excavated soil n.exc 50 mtr and depositing where directed at a level n exc 1.5 m from starting point complete all as directed |
| 35 | Taking down galvanised water tubing and fittings, including cleaning and refixing or removing to store for credit of 80mm bore |
| 36 | Re-fixing old GI tubing after threading, cleaning and fix with new fittings to walls and ceiling or laid in floor and trenches complete size 80mm bore pipe. |
| 37 | Taking down existing rusted GI tubing and supply & fixing only medium grade including cutting bending and necessary fittings like union, elbow, bend, Tee etc as required at site fix on wall or ceiling or laid under floor or in trench complete all as directed of 80mm bore pipe. |
| 38 | Disconnecting and taking out old unsv gate valve and S& F Gun Metal globe/ gate valve with iron wheel head screwed both ends of 50mm bore. |
| 39 | Disconnecting and taking out old unsv gate valve and S& F Gun Metal globe/ gate valve with iron wheel head screwed both ends of 80mm bore. |
| 40 | Taking down or up and Repairing to existing pipe line where leakage occurred incl threading all necessary required fittings and earth work of 80mm bore pipe. |
| 41 | Taking down and removing u/s old unsv CI body sluice valve and supply, install, testing and commissioning of cast iron sluice valve 80mm dia, class pin 1.60 ISI marked with both ends flanged with cast irin body and wheel and brass spindle non rising type including necessary jointing material with nuts, bolts, washers and rubber sheet 4mm thick with 2 Nos of 80mm GI flanged for GI pipe complete all as directed. |
| 42 | Material and Labour for preperation of old iron surfaces of any description and applying two coat of synthetic enamel paints over a coat of zinc chrome priming paints as per existing colour or directed by Engr-in-charge. |
| 43 | Repairing of existing valve pit chamber of any size by re-plastering, finishing & whitewash/painting of chamber cover and cleaning of surrounding area including removal of unserviceable material from site all as directed. |
| 44 | Material and Labour for cutting existing road/hard standing 40 cm wide including necessary excavation and earth work for taking out/laying pipe and making good disturbed surfaces to match with existing complete all as specified and as directed. |
| 45 | Taking up or down CI non return valve removing from site and supply and fixing of new 80mm CI non return valve brass spindle with both ends flanged and drilled incl necessary nut bolts nad washers and rubber gasket sheet 4mm thick with 02 Nos of 80mm GI flanged for GI pipe complete all as directed. |
| 46 | Repair & Servicing of DG set 15 KVA installed at Booster No 3 pump house to carried out following works :-Replacement of Oil Filter, Diesel filter, Engine oil, and Supply & fixing of Battery charger and testing after repair all as specified and directed by Engr-in-charge. |
| 47 | Supply,fixing and installation of Battery 12.8V 90 Ah for DG Set complete all as specified and directed by Engr- in- charge. Make : Exide/Amaron/Okaya |
| 48 | M & L for two coat of synthetic enamel paint on distribution pipe line all as per specified and directed by Engr-in-charge. Material and Labour for Testing of water from approved Govt lab samples collected from pump house No-01 at main Gate as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge, the test report includes following parameters:- PH value, TDS(mg/l), Hardness (as CaCO3) (mg/l), Fluoride (mg/l), Chloride (mg/l),Turbidity (NTU), E.Coli (cfu), Free residual Chlorine Please Enable Macros to View BoQ information |