| 1 | Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. [Note : The Excavation and earth work shall be mesured and paid separately under relevant item of Schedule.] |
| 2 | Supply, laying, jointing & testing of LT cable,trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. |
| 3 | All as per ser item No 2 above but of cross sectional area 16 sqmm 4 core complete all as specified and as directed. |
| 4 | All as per ser item No 2 above but of cross sectional area 25 sqmm 4 core complete all as specified and as directed. |
| 5 | All as per ser item No 2 above but of cross sectional area 35 sqmm 3.5 core complete all as specified and as directed. |
| 6 | All as per ser item No 2 above but of cross sectional area 50 sqmm 3.5 core complete all as specified and as directed. |
| 7 | All as per ser item No 2 above but of cross sectional area 95 sqmm 3.5 core complete all as specified and as directed. |
| 8 | All as per ser item No 2 above but of cross sectional area 120 sqmm 3.5 core complete all as specified and as directed. |
| 9 | All as per ser item No 2 above but of cross sectional area 240 sqmm 3.5 core complete all as specified and as directed. |
| 10 | Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pilar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil including filling in river sand & bricks as reqd and connecting the cables with bus bars including provision of suitable size of aluminium lugs complete all as specified and as directed. |
| 11 | Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. [Note : The serviceable cable obtained from taking out shall be reused.] |
| 12 | Supply and fixing in replacement of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 63 Amps of breaking capacity 25 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 13 | Supply and fixing in replacement of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 100 Amps of breaking capacity 25 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 14 | Supply and fixing in replacement of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 160 Amps of breaking capacity 25 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 15 | Supply and fixing in replacement of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 200 Amps of breaking capacity 25 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 16 | Supply and fixing in replacement of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 250 Amps of breaking capacity 25 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 17 | Supply and fixing in replacement of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 400 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 18 | S&F in replacement MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 19 | M&L in replacement for Heat shrinakable straight through joint for 3.5 / 4 core cable 25sqmm to 50 sqmm and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 20 | M&L in replacement for Heat shrinakable straight through joint for 3.5 / 4 core cable 70 sqmm to 120sqmm and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 21 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed. |
| 22 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth as in soft/loose soil complete all as specified and as directed. |
| 23 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 24 | M&L providing sand cushioning for protection of UG cable (8 cm deep before laying & 15 cm above the top edge of cable after laying) in trenches with dry (coarse) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified & as directed. (NOTE : Punned thickness of 18 cm only shall be considered for payment purpose) |
| 25 | Supply and laying brickwork with locally (Sub Class B Bricks) available best quality bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified & as directed. |
| 26 | Laying only Old bricks for protection of LT UG cable complete all as specified and as directed.(Serviceable bricks obtained from Item No 01 have-in-before) |
| 27 | M & L horizontal boring suitable upto 80mm steel tubing across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. [Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A']. |
| 28 | M&L 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 29 | M&L 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 30 | S&F aluminium bus bar of size 400 mm X 40 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and as directed. |
| 31 | S&F aluminium bus bar of size 600 mm X 20 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and as directed. |
| 32 | Dismantling of old U/S LT feeder pillar box/LT junction box including PCC/Brick wks foundation after disconnecting of all elecrical connection complete all as specified and as directed. |
| 33 | Supply ,fabrication, installation and testing in replacement of LT out door type factory made ,CPRI Approved, junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. (a) Copper bus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No complete all as specified and as directed. |
| 34 | Supply, fabrication, installation, testing and commisioning in replacement of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Approved, water and vermin proof protection pedestal type feeder pilar box of minimum size 1200 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 800 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be omplete painted with Powder Coated paint of approved shade. \\"U\\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \\"F\\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including the following accessories : - [Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Incomming Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (b) Outgoing Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos (c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No complete all as specified and as directed. |
| 35 | Supply, fabrication, installation, testing and commisioning in replacement of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Approved, water and vermin proof protection pedestal type feeder pilar box of minimum size 1200 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 800 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be omplete painted with Powder Coated paint of approved shade. \\"U\\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \\"F\\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (Incomming) (b) Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going) (c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 100 amps including all fixing accessories with both ends spreader links . ( Outgoing -02 Nos) (e) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . ( Outgoing -01 Nos) (f) MCB SPN 40 Amps 240 volts 10 KA - 4 Nos (g) Neon indicator lamp with holder (RYB) = 03 Nos (h) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (i) Digital Ammeter of range (0-300) Amp flush mounting type with selector switch = 01 No (j) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 36 | Supply, fabrication, installation, testing and commisioning in replacement of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Appoved, water and vermin proof protection pedestal type feeder pilar box of minimum size 1200 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provision of cable looping box of size 800 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \\"U\\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \\"F\\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including the following accessories : - [Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (Incomming) (b) Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going) (c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 160 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . ( Outgoing -04 Nos) (e) MCB SPN 40 Amps 240 volts 10 KA - 4 Nos (f) Neon indicator lamp with holder (RYB) = 03 Nos (g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (h) Digital Ammeter of range (0-200) Amp flush mounting type with selector switch = 01 No (i) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 37 | M&L preparation of the old decorated existing external steel surface of feeder pillar boxes/LT panels of any size and description in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopponf required and applying two coats of Asian aspa paint (Mahindra Grade) by using spray painting machine on old prepared surface including marking of Sub Stn No, Feeder No and feeding area/Bldg with applying synthetic enamel paint (1st grade) complete all as specified and as directed. |
| 38 | S&F LED indicating RED lamp, including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 39 | S&F LED indicating YELLOW lamp, including necessary connection complete and including taking down / dismantling of old existing unserviceable one all as specified and as directed. |
| 40 | S&F LED indicating BLUE lamp, including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 41 | S&F CT coil 100/5 Amps including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 42 | S&F Digital Voltmeter of size 96x96 sqmm size with selector switch 0-500 Volts including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 43 | S&F Digital Ammeter 0-600 Amps of size 96x96 sqmm with selector switch including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 44 | S&F danger notice board / plate of size 20 cm x 15 cm, made out of 1.6 mm thickness mild sheet, vitreous enamelled white letters, figure and conventional skull and bones in Red colour and fixed with nuts and bolts for 1100 volts current and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 45 | Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Permises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point complete all as directed. [Note : The item shall be operated maximum 2 (Two) times in the entire period of the Contract period and measurement will be taken every time independently for payment]. |
| 46 | S&F 25 x 3 mm galvanised iron strip,earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or fixed to poles or roof with saddel and screw current and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 47 | S&F Copper strip of size 20x3 mm for earth continuity conductor fixed on PCC block and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 48 | Dismantling of existing unserviceable loose/disturbed Aluminum strip/GI Strip/Copper strip/Termination rod of any sizes on roof/down conductor fixed on wooden guities /directly on roof including screws etc complete all as specified and as directed. |
| 49 | S&F 32 x 6 mm galvanised iron strip,earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or fixed to poles or roof with saddel and screw current and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 50 | S&F porcelain insulator of size 65mm dia x 31mm light x 20mm hole with three nos hole including GI bolts and nuts of required size and two nos washer on PCC, fixing strip including taking down/dismantling of old existing unserviceable one complete all as specified and as directed. |
| 51 | S&F air termination single pointed aluminium rod 12mm dia and 300 mm long and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 52 | M & L PCC work providing PCC type C1 (1 : 3 : 6) with 20 mm graded aggregate in foundation for panel and finishing the surface even and smooth without using extra cement including breaking of old PCC complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 53 | M & L PCC work providing PCC type C1 (1 : 3 : 6) with 20 mm graded aggregate in foundation for panel and finishing the surface even and smooth without using extra cement including breaking of old PCC complete all as specified and as directed. Please Enable Macros to View BoQ information |