| 1 | Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed. |
| 2 | Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed. |
| 3 | M & L for concealed point wiring complete with multistranded copper conductor (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code in conduit system of wiring, drawn in including PVC conduit not less than 20 mm dia concealed duly fixed with U-Clips, including cutting chases, finising of slote by means of cement mortor making good to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable (FRLS) as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified and directed by Engr-in-Charge. |
| 4 | One light point controlled by one one/way switch. |
| 5 | One Fan point controlled by one one/way switch. |
| 6 | One 3 pin 5 Amps socket outlet on same board with other switch. |
| 7 | One 3 pin 5 Amps socket outlet on independent board. |
| 8 | One light point controlled by two way switches |
| 9 | One bell point controlled by one way switches |
| 10 | All as per item No. 3 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board |
| 11 | M & L for point wiring complete with multistranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code including PVC casing caping. the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified. |
| 12 | One light point controlled by one one/way switch. |
| 13 | One Fan point controlled by one one/way switch. |
| 14 | One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size. |
| 15 | All as per item No. 5 above but using 4 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board |
| 16 | M & L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed all as directed. Note : (i) Two single core cable, one run of earth copper conductor and one run 20MM PVC Conduit will be measured and paid as one unit length. |
| 17 | M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed all as directed.Note : (i) Two single core cable, one run of earth copper conductor and one run 20MM PVC Conduit will be measured and paid as one unit length. |
| 18 | S&F switch piano flush type single pole one way 5 Amp 240 Volts. |
| 19 | S&F switch piano flush type single pole two way 5 Amp 240 Volts. |
| 20 | S&F switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt. |
| 21 | S&F switch socket combination 3 pin 5 and 15 Amp 2 in one flush with inbuilt indicating lamp. |
| 22 | S & F Bell switch including Bell ding dong type, one way, 240 volts, AC. |
| 23 | S&F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. |
| 24 | S&F ceiling fan condenser paper type 2.5 MFD |
| 25 | S/F in repair MCB TPN DBs Vertical type 4 way double door provision for FP as incomer and SP as outgoing all as directed. |
| 26 | S/F in repair sheet metal enclosure for MCB single pole and neutral 08 way 240 volts, 200 Amp rated bus bar. |
| 27 | S & F MCB TPN 63 Amps 25 KA rupturing capacity of |
| 28 | S & F MCB SPN 32 Amps 10 KA rupturing capacity. |
| 29 | S&F MCB SP 6 to 25 Amps 240V, 10 KA 'B' curve Complete with connection testing and commissioning. |
| 30 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd. |
| 31 | S & F of ceiling fan operated with blades, anti suicide rod from existing roof / trus to fall ceiling, electronic regulator operated and accessories, 230V, 35 Watts, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 32 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type/Ceiling mounted (As decided by Engr-in-Charge) with mains current 0.400 luminous efficiency >120 lux/watts, potted electric LED dimmer (5MPS based constant current supply) with loner THD , CCT (2700-6500) as decided by Engr-in-Charge and impact resistance of IK07 with 10KV Built-in Surge Protection Device other safety tests as per IS 15885 Part-2/sec-13 high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed by Engr-in-Charge. |
| 33 | S&F of 4' 20W LED Tube With Batten with system lumen output of 2400 lumens. System Efficacy should be > 120lm/ W. The Luminaire Should have Cool Daylight Color temp of (2000k to 6500K) as decided by Engr-in-Charge & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV.All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accridiated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED batten light conforms to applicable IS all as directed by Engr-in-Charge. |
| 34 | S&F of 1' 5W LED Tube With Batten with system lumen output of 2400 lumens. System Efficacy should be > 120lm/ W. The Luminaire Should have Cool Daylight Color temp of (2000k to 6500K) as decided by Engr-in-Charge & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV.All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accridiated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED batten light conforms to applicable IS all as directed by Engr-in-Charge. |
| 35 | M & L testing of earth pit and charging by salt water, writing of resistance on the notice board including paint on earth pit cover with red or yellow of the building as per direction of Engr-in-Charge.Note : (i) Testing megger with calibration report shall be provided by the contractor. (ii) Earth Test report will submitted to Engr-in-Charge for record. |
| 36 | Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes for srl Item No. 3.06 & 3.07.(a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing work is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. |
| 37 | M & L for fabrication of sheet metal board of size 60x50x20 CM made of 2mm thick MS Sheet with locking arrangement dully two coat of synthetic enamelled paint over one coat of red oxide. All as specified and directed by Engr in charge. Note :- Cutting and chasing in stone/Brick masonary and making good to disturbed surfaces will be including in item rate . |
| 38 | Note :-(i) Item No 1 to 25 All items manufacture should be after Jul 2025.(ii) Contractor should be arrange necessary T&P for execute the work.(iii) All LED light warranty should be 2 Years after completion of the work. (iv) Switch and other connected items model should be decided by Engr-in-Charge. Please Enable Macros to View BoQ information |