| 1 | Carriage following material from Centre Stores, Asfabad to site of work (Distance 00-20 Kms.) through the Kacha and Pakka road including the work of its loading and unloading at the respective ends as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work in the area of EUDC, Firozabad (Material shall be provieded by Department) | Carriage following material from Centre Stores, Asfabad to site of work (Distance 00-20 Kms.) through the Kacha and Pakka road including the work of its loading and unloading at the respective ends as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work in the area of EUDC, Firozabad (Material shall be provieded by Department) |
| 2 | 33 KV 3x300 XLPE Cable | 33 KV 3x300 XLPE Cable |
| 3 | 11 KV 3x120 XLPE Cable | 11 KV 3x120 XLPE Cable |
| 4 | 11 KV 3x185 XLPE Cable (Overhead) | 11 KV 3x185 XLPE Cable (Overhead) |
| 5 | H/S O/D 33 KV 3x300 sqmm J/kit | H/S O/D 33 KV 3x300 sqmm J/kit |
| 6 | H/S O/D 11 KV 3x120 sqmm J/kit | H/S O/D 11 KV 3x120 sqmm J/kit |
| 7 | H/S O/D 11 KV 3x185 sqmm J/kit | H/S O/D 11 KV 3x185 sqmm J/kit |
| 8 | 11 Mtr STP SP-55 Pole (Galvanised) | 11 Mtr STP SP-55 Pole (Galvanised) |
| 9 | 11 Mtr PCC Pole | 11 Mtr PCC Pole |
| 10 | 13M, ST Pole - SP - 70 Galvanised | 13M, ST Pole - SP - 70 Galvanised |
| 11 | MS T-off Channel | MS T-off Channel |
| 12 | 33KV \\"V\\" type Cross arm 100 x 50 x 6 mm, M.s Chaneel | 33KV \\"V\\" type Cross arm 100 x 50 x 6 mm, M.s Chaneel |
| 13 | Disc Fitting for drop B&S type | Disc Fitting for drop B&S type |
| 14 | Disc Insulator B&S Polymeric Type | Disc Insulator B&S Polymeric Type |
| 15 | Polymeric 33KV Pin Insulator | Polymeric 33KV Pin Insulator |
| 16 | ACSR Panther Conductor | ACSR Panther Conductor |
| 17 | Complete Stay 9GI Stay Rod 20x1800 mm, stay wire 7/8 SWG, 10 KG, Stay Clamp, Bolt, nut and washer with concrete grouting) | Complete Stay 9GI Stay Rod 20x1800 mm, stay wire 7/8 SWG, 10 KG, Stay Clamp, Bolt, nut and washer with concrete grouting) |
| 18 | 33 KV CT(Outdoor) 200/100/1 Amp. | 33 KV CT(Outdoor) 200/100/1 Amp. |
| 19 | Supply of the Following Material. | Supply of the Following Material. |
| 20 | HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe for laying of 33KV, 3x300Sq.mm | HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe for laying of 33KV, 3x300Sq.mm |
| 21 | HDPE Pipe PE-80, PN-6, DN-140mm dia Pipe for laying of 11KV 3x120 | HDPE Pipe PE-80, PN-6, DN-140mm dia Pipe for laying of 11KV 3x120 |
| 22 | Clamp for T-off Channel with Bolts and Nuts | Clamp for T-off Channel with Bolts and Nuts |
| 23 | Clamp for 33 KV \\"V\\" type Cross arm with bolts and nuts | Clamp for 33 KV \\"V\\" type Cross arm with bolts and nuts |
| 24 | G I Barbed Wire | G I Barbed Wire |
| 25 | Bracing set 4.3 x 4.3 Mtr Angle Iron 65x65x6 mm with holding clamp | Bracing set 4.3 x 4.3 Mtr Angle Iron 65x65x6 mm with holding clamp |
| 26 | Nut Bolt and washer all sizes | Nut Bolt and washer all sizes |
| 27 | F-Bracket for 33 KV Fitting top Pin Insulator with nut & bolts | F-Bracket for 33 KV Fitting top Pin Insulator with nut & bolts |
| 28 | F-Bracket for 11KV Fitting top Pin Insulator with nut & bolts | F-Bracket for 11KV Fitting top Pin Insulator with nut & bolts |
| 29 | Only Erection of the following Material | Only Erection of the following Material |
| 30 | Clamp for T-off Channel with Bolts and Nuts | Clamp for T-off Channel with Bolts and Nuts |
| 31 | Clamp for 33 KV \\"V\\" type Cross arm with bolts and nuts | Clamp for 33 KV \\"V\\" type Cross arm with bolts and nuts |
| 32 | G I Barbed Wire | G I Barbed Wire |
| 33 | Bracing set 4.3 x 4.3 Mtr Angle Iron 65x65x6 mm with holding clamp | Bracing set 4.3 x 4.3 Mtr Angle Iron 65x65x6 mm with holding clamp |
| 34 | Nut Bolt and washer all sizes | Nut Bolt and washer all sizes |
| 35 | F-Bracket for 33 KV Fitting top Pin Insulator with nut & bolts | F-Bracket for 33 KV Fitting top Pin Insulator with nut & bolts |
| 36 | F-Bracket for 11KV Fitting top Pin Insulator with nut & bolts | F-Bracket for 11KV Fitting top Pin Insulator with nut & bolts |
| 37 | Erection of single pole structure 11 ST/P PCC &13 Mtrs ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. | Erection of single pole structure 11 ST/P PCC &13 Mtrs ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. |
| 38 | Grouting of 11 ST/P PCC &13 Mtrs ST Pole Long As per Respo Norms (Cement, Sand, Blast Stone with the ratio 1:4:8) will be provided by conractor | Grouting of 11 ST/P PCC &13 Mtrs ST Pole Long As per Respo Norms (Cement, Sand, Blast Stone with the ratio 1:4:8) will be provided by conractor |
| 39 | Earthing of pole by M S Earthing Rod 20 x2500 mm and 6 SWG earthing wire etc | Earthing of pole by M S Earthing Rod 20 x2500 mm and 6 SWG earthing wire etc |
| 40 | Complete Stay 9GI Stay Rod 20x1800 mm, stay wire 7/8 SWG, 10 KG, Stay Clamp, Bolt, nut and washer with concrete grouting) | Complete Stay 9GI Stay Rod 20x1800 mm, stay wire 7/8 SWG, 10 KG, Stay Clamp, Bolt, nut and washer with concrete grouting) |
| 41 | Laying of 33 KV 3x300 Cable Including HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe with HDD (trenchless) method including cable laying. | Laying of 33 KV 3x300 Cable Including HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe with HDD (trenchless) method including cable laying. |
| 42 | Laying of 11 KV Cable 3x120 sqmm Including HDPE Pipe PE-80, PN-6, DN-140mm dia Pipe with HDD (trenchless) method including cable laying. | Laying of 11 KV Cable 3x120 sqmm Including HDPE Pipe PE-80, PN-6, DN-140mm dia Pipe with HDD (trenchless) method including cable laying. |
| 43 | Digging & laying of 33/11 KV Cable including HDPE pipe (if taken in estimate) intranch with sand & brick (Open Trench Method) | Digging & laying of 33/11 KV Cable including HDPE pipe (if taken in estimate) intranch with sand & brick (Open Trench Method) |
| 44 | Fixing of cable box/Straight Through as suitable size as per direction of supervising engineer as per Respo Norms. | Fixing of cable box/Straight Through as suitable size as per direction of supervising engineer as per Respo Norms. |
| 45 | H/S O/D 33 KV 3x300 sqmm J/kit | H/S O/D 33 KV 3x300 sqmm J/kit |
| 46 | H/S O/D 11 KV 3x120 sqmm J/kit | H/S O/D 11 KV 3x120 sqmm J/kit |
| 47 | H/S O/D 11 KV 3x185 sqmm J/kit | H/S O/D 11 KV 3x185 sqmm J/kit |
| 48 | Laying, stringing, sagging, binding and jumpering etc of following conductor on the erected supports, as per RESPO norms. | Laying, stringing, sagging, binding and jumpering etc of following conductor on the erected supports, as per RESPO norms. |
| 49 | ACSR Panther Conductor | ACSR Panther Conductor |
| 50 | Laying of 33/11 KV Cable in Air | Laying of 33/11 KV Cable in Air |
| 51 | 11 KV 3x185 XLPE Cable (Overhead) | 11 KV 3x185 XLPE Cable (Overhead) |
| 52 | Dismantle of all old existing assesories where as it is required & carriage to centre store Asfabad 0-20 Km | Dismantle of all old existing assesories where as it is required & carriage to centre store Asfabad 0-20 Km |
| 53 | Erection of 33 KV CT(Outdoor) 200/100/1 Amp.As per respo norms Including Structure (All required structur meterial shall be provide by contractor) | Erection of 33 KV CT(Outdoor) 200/100/1 Amp.As per respo norms Including Structure (All required structur meterial shall be provide by contractor) |