| 1 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 2 | Providing & erecting 4 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB | Providing & erecting 4 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 3 | Supplying & erecting all weather proof CRCA sheet metal enclosure 24x 24 inch of 1.2mm thickness with 4 pole bus bar having rated short - circuit breaking capacity (Icn) 10kA complete with door, 1.2mm thickness, surface/flush mounted erected on provided angle iron/GI frame | Supplying & erecting all weather proof CRCA sheet metal enclosure 24x 24 inch of 1.2mm thickness with 4 pole bus bar having rated short - circuit breaking capacity (Icn) 10kA complete with door, 1.2mm thickness, surface/flush mounted erected on provided angle iron/GI frame |
| 4 | Supplying and erecting four pole power contactor 430V, 40A for time switchcomplete erected on provided wooden block/ box, with necessary materials | Supplying and erecting four pole power contactor 430V, 40A for time switchcomplete erected on provided wooden block/ box, with necessary materials |
| 5 | Supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box | Supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box |
| 6 | Providing and installation of microprocessor based Earth leakage relay with CBCT 100 mm ID having leakage current setting 30 mA - 3 A having auxillary voltage 110 V AC | Providing and installation of microprocessor based Earth leakage relay with CBCT 100 mm ID having leakage current setting 30 mA - 3 A having auxillary voltage 110 V AC |