| 1 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (Make: Havells / KEI / Polycab / Finolex) a) 3 x 2.5 sqmm. |
| 2 | b) 4 x 6 sqmm. |
| 3 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (make: BEC/AKG) a) 20 mm |
| 4 | b) 25 mm |
| 5 | Providing and fixing 125 Ampere rating, 36 KA breaking capacity FPMCCB with thermomagnetic release along with terminal spreaders,including mounting on the SS enclosure, making connections, testing etc complete as required as per site location. (Make: Lauritz Knudsen/ ABB/ Legrand/ Havells) |
| 6 | Providing and fixing SS enclosure with mounting holes for easy wall mounting, louvers for better heat dissipation, generous space for cable termination and IK08 and IP30 Protection,dismentelling the existing supply system,mounting the SS enclosure containing FPMCCB on the wall, making connections, testing etc complete as required as per site location. (Make: Lauritz Knudsen/ ABB/ Legrand/ Havells) |
| 7 | Supplying and fixing 4 way (4 + 12), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB /Isolator). (Make: Lauritz Knudsen/ABB/Legrand/Havells) |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Lauritz Knudsen/ABB/Legrand/Havells). a) Single Pole. |
| 9 | b) 32 Ampere rating Triple pole and neutral MCB. |
| 10 | Supplying and fixing 63 ampere rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Lauritz Knudsen/ABB/Legrand). |
| 11 | Supplying and fixing of the following items including dismantling the old electrical accessories (where ever required), making suitable necessary modification/arrangement (i/c petty items) for fixing the new items and making connections etc complete as reqd as per the site location given by the Engineer-in-Charge. a) 450 mm (18\\") heavy duty exhaust fan, single phase, 900 RPM, 2295 CFM along with louvers/ shutters complete with frame including dismantling the old ones making connections etc complete as required as per site location. (Make: Almonard) |
| 12 | b) 450 mm (18\\") wall mounting air circulator, single phase, 1440 RPM, 150 M3/min air delivery, double ball bearing and powerful heavy duty motor. (Make: Almonard, Model: Tempest) |
| 13 | Supplying and fixing 4 feet LED batten fitting with integral electronic driver and LED tube operated on 230 V 50 Hz AC supply on surface by providing pvc round block (2 Nos each) for mounting arrangement, connections etc complete as required. (System wattage: 20-22 W; Lumen output: 1850-2000 lumens). (Make: Philips/ Havells/ Wipro/ Polycab/ Crompton). |
| 14 | Supplying and laying of 5 core x 1.50 sqmm PVC insulated and PVC sheathed armoured copper conductor cable from lift machine room to the existing wall of lift well shaft/ surface/ trench etc wherever required including making connections and testing, saddling, dismantling the old cables (if any) etc complete as reqd as per site location. (Make: Havells/Polycab/KEI) |
| 15 | Supplying and laying of 3 core x 2.5 sqmm PVC insulated and PVC sheathed armoured copper conductor cable from lift machine room to the existing wall of lift well shaft/ surface/ trench etc wherever required including making connections and testing, saddling, dismantling the old cables (if any) etc complete as reqd as per site location. (Make: Havells/Polycab/KEI) |
| 16 | Supplying of 9-10 watt LED bulkhead luminaire complete with IP65/66 protection suitable for surface and wall mounting applications including dismantling of the existing old fittings, installing the new fittings in existing lift shafts with minor adjustment, connections,testing and commissioning etc complete as required as per site location. (Make: Philips Model: Endura LED WT202W LED6S CW PSU S2 PC / Havells Model: HEXAFT10WLED857SSYMBOPC / Wipro Model: LW07-141-XXX-57-G1 / CG Model: LBHE-10-CDL) |
| 17 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (Make: Anchor/ Legrand/ MK/ Havells) |
| 18 | Supplying and fixing metal box of 75mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A ceiling rose, making connections, painting etc complete as required as site location. (Make: Anchor/ Legrand/ MK/Cona/ Havells) |
| 19 | Supplying and fixing metal box of 75mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 2 way 5/6 A piano type switch, connections, painting etc. as required. (Make: Anchor/ Legrand/ MK/ Havells) |
| 20 | Supplying and laying of 4 core x 16 Sq. mm XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade on the existing wall surface including making connections and testing, saddling etc complete as reqd as per site location. (Make:Havells/Polycab/KEI/Finolex) |
| 21 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 16 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 22 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 23 | Supplying and laying 25mm x 5mm GI strip at 0.50 Mtr below ground as strip earth electrode, including connection/teminating with GI nut, bolt, spring washer including excavation and refilling etc complete as required. (Note: i) Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer spaced at 50 mm. ii) Providing and fixing of pvc insulation sleeve on G.I strip wherever required to be carried out as per site requirement and as per instruction of Engineer-in-charge without any extra charges.) |
| 24 | Providing and fixing 25 mm X 5 mm G.I strip on surface or in recess for horizontal / vertical run including making connection / terminating with GI nut,bolt,spring washer etc complete as required as per site requirement and as per instructions of Engineer-in-charge. (Note: i) The above job also includes arrangement of jhula suitable for building height, safety arrangement for vertical run installation of G.I strip. ii) Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer spaced at 50 mm. iii) Providing and fixing of pvc insulation sleeve on G.I strip wherever required to be carried out as per site requirement and as per instruction of Engineer-in-charge without any extra charges. iv) The G.I strip is to be clamped using GI clamps and distance between two clamps should not be more than 0.5 Mtr in case of surface GI strip.) |
| 25 | Providing and fixing testing joint, made of 25 mm X 5 mm thick G.I. strip, 125mm long, with 4 nos. of G.I. bolts, nuts, chucknuts and spring washers etc complete as required |
| 26 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc complete as required as per site requirement. |
| 27 | Providing and fixing of 25 mm x 5 mm GI strip in 40mm dia G.I pipe from earth electrode making connection with G.I. nut, bolt, spring, washer excavation, including cutting of RCC / pucca road, repairing the same (wherever reqd) and re-filling etc complete as required as per the instruction of Engineer-in-charge. (Note: i) Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer spaced at 50 mm. ii) Providing and fixing of pvc insulation sleeve on G.I strip wherever required to be carried out as per site requirement and as per instruction of Engineer-in-charge without any extra charges. iii) The G.I strip is to be clamped using GI clamps and distance between two clamps should not be more than 0.5 Mtr in case of surface GI strip.) Please Enable Macros to View BoQ information |