| 1 | Dismantling, stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, complete all as specified and directed. |
| 2 | M & L Sub base cement concrete 100mm thick type D-2, 1:4:8 (40 mm graded aggregate), complete all as specified and directed. |
| 3 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 4 | Taking up or down steel tubing and connection including cleaning for refixing or removal to store for 15 mm bore, complete all as specified and directed. |
| 5 | Taking up or down steel tubing and connection including cleaning for refixing or removal to store for 20 mm bore, complete all as specified and directed. |
| 6 | Taking up or down steel tubing and connection including cleaning for refixing or removal to store for 25 or 32 mm bore, complete all as specified and directed. |
| 7 | Taking up or down steel tubing and connection including cleaning for refixing or removal to store for 40 or 50 mm bore, complete all as specified and directed. |
| 8 | Supply & fixing UPVC pipes out side dia 15 mm of pressure rating 10 Kgf/Sqcm, fixed to walls, ceilings or in floors etc, complete all as specified and directed. |
| 9 | Supply & fixing UPVC pipes out side dia 20 mm of pressure rating 10 Kgf/Sqcm, fixed to walls, ceilings or in floors etc, complete all as specified and directed. |
| 10 | Supply & fixing UPVC pipes out side dia 25 mm of pressure rating 10 Kgf/Sqcm, fixed to walls, ceilings or in floors etc, complete all as specified and directed. |
| 11 | S&F tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floor for 15 mm bore, complete all as specified and directed. |
| 12 | S&F tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floor for 20 mm bore, complete all as specified and directed. |
| 13 | S&F tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floor for 25 mm bore, complete all as specified and directed. |
| 14 | S&F tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floor for 40 mm bore, complete all as specified and directed. |
| 15 | Refixing old steel tubing and connection in new or old portion (walls ceiling, floors etc) for 15 mm bore, complete all as specified and directed. Note:- Serviceable pipe received from item No. 4 shall be reuse. |
| 16 | Refixing old steel tubing and connection in new or old portion (walls ceiling, floors etc) for 20 mm bore, complete all as specified and directed. Note:- Serviceable pipe received from item No. 5 shall be reuse. |
| 17 | Refixing old steel tubing and connection in new or old portion (walls ceiling, floors etc) for 25 mm bore, complete all as specified and directed. Note:- Serviceable pipe received from item No. 6 shall be reuse. |
| 18 | Refixing old steel tubing and connection in new or old portion (walls ceiling, floors etc) for 40 or 50 mm bore, complete all as specified and directed. Note:- Serviceable pipe received from item No. 7 shall be reuse. |
| 19 | Supply & fixing in repair for 15 mm bore in existing or new pipe GI ÏSI Marked Embosed \\"fittings Like union joint, socket reducer etc, complete all as specified and directed. |
| 20 | Supply & fixing in repair for 20 mm bore in existing or new pipe GI ÏSI Marked Embosed \\"fittings Like union joint, socket reducer etc, complete all as specified and directed. |
| 21 | Supply & fixing in repair for 25 mm bore in existing or new pipe GI ÏSI Marked Embosed \\"fittings Like union joint, socket reducer etc, complete all as specified and directed. |
| 22 | Supply & fixing in repair for 40 mm bore in existing or new pipe GI ÏSI Marked Embosed \\"fittings Like union joint, socket reducer etc, complete all as specified and directed. |
| 23 | Supply & fixing in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 40 mm bore pipe, complete all as specified and directed. |
| 24 | Supply & fixing in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore pipe, complete all as specified and directed. |
| 25 | Supply & fixing in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 25 mm bore pipe, complete all as specified and directed. |
| 26 | Supply & fixing in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 15 mm bore pipe, complete all as specified and directed. |
| 27 | Supply & fixing in repair Chromium plated brass angle valve for 15mm bore pipe, fixed, complete all as specified and directed. |
| 28 | Supply & fixing in repair, two way angle valve cock chromium plated brass fancy type bore 15mm, complete all as specified and directed. |
| 29 | Supply & fixing in repairs PVC connection 15mm dia and 45cm long with 2 Nos PTMT nuts, complete all as specified and directed. |
| 30 | Taking down eaves gutters and rainwater pipes (any size orpattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 31 | S&F for PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 110mm bore, complete all as specified and directed. |
| 32 | S&F for PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 75 mm bore, complete all as specified and directed. |
| 33 | S&F for PVC (SWR) bends any radius, 110 mm bore, complete all as specified and directed. |
| 34 | S&F for PVC (SWR) bends any radius, 75 mm bore, complete all as specified and directed. |
| 35 | S&F for PVC (SWR) branch piece, single (single Y) equal or unequal radius, 110 mm bore, complete all as specified and directed. |
| 36 | S&F for PVC (SWR) branch piece, single (single Y) equal or unequal radius, 75 mm bore, complete all as specified and directed. |
| 37 | S&F for PVC (SWR) branch piece, single (single T) equal or unequal radius, 110 mm bore, complete all as specified and directed. |
| 38 | S&F for PVC (SWR) branch piece, single (single T) equal or unequal radius, 75 mm bore, complete all as specified and directed. |
| 39 | S&F for PVC (SWR) reducers, 110 mm bore, complete all as specified and directed. |
| 40 | S&F for PVC (SWR) reducers, 75 mm bore, complete all as specified and directed. |
| 41 | S&F for PVC (SWR) vent cowl, 110 mm bore, complete all as specified and directed. |
| 42 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges, complete all as specified and directed. |
| 43 | S & F Pre- painted galvalumealuminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including scafoldings of any hieght, complete all as specified and directed. |
| 44 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 45 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 46 | S&F for Rolled mild steel sections conforming to Gde Fe-290(Gde-165-E) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates, complete all as specified and directed. |
| 47 | Material & Labour and fixed in repair for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed. |
| 48 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles including removing debris out side MD land, complete all as specified and directed. |
| 49 | Material and Labour for Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean raddius built in CM 1:6, complete all as specified and directed. |
| 50 | Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site out side MD land, complete all as specified and directed. |
| 51 | M & L for Old unserviceable loose spalled concrete, chiseled from roof ceiling with the help of scrapers, chisel & hammer, cleaning of rust from mild steel rod, applying cement slurry spray 3.00 kg per sqm by paint brush over cleaned surface and thereafter rendering 20-30mm Thick ready mix plaster in multi layer for ceiling on brick wall or concrete surfaces including making groove of appropriate size and finished even & smooth without using extra cement including two coat of OBD / Weathercoat, complete all as specified and as directed by Engr-in-Charge. |
| 52 | Material and labour for 15 mm thick ready mix plaster in single layer with liquid water proofing compound on fair faces of brick wall or concrete surfaces, finished even and fair, including use of scaffolding, complete all as specified and directed.by Engr-in-Charge. |
| 53 | Material and labour for 12 mm thick Ready Mix Plaster in single layer on other than fair faces of concrete surfaces in wall (internal surface) and finished even and smooth, complete all as specified and directed by Engr-in-Charge. |
| 54 | Material and Labour for applying one coat of wall putty 1 mm Average thickness on wall surface incl rubbing through authorised applicators, complete all as specified and directed. |
| 55 | Material and Labour for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper over a coat alkali resistant primer coat through authorised applicators of paint manufacturers only of approved shade, complete all as specified and directed. |
| 56 | Material and Labour for complete removal of existing treatment of old surface of wall and applying two coats of oil emulsion distemper through authorised applicators of paint manufacturers only of approved shade, complete all as specified and directed. |
| 57 | Material and Labour for preparing newly plastered surfaces of walls / ceilings and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat and top coat over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings, complete all as specified and directed. |
| 58 | Material and Labour for complete removal of existing treatment of old plastered surfaces of walls / ceilings and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat and top coat over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings, complete all as specified and directed. |
| 59 | Demolition/ takingdown existing roof treatment incl PCC pedding by picking sweeping, cleaning and washing down with water to remove dust,durt etc and brushing neat cement slurry @ 3 KG/sqm, complete all as specified and directed. |
| 60 | M & L for plain cement concrete padding 1:2:4 type B-0 of uniform thickness 25 mm avg top surface of pain cement concrete padding shall be furnished even and smooth without using extra cement, complete all as specified and directed. |
| 61 | M&L for 15 mm thick screedi bedding CM 1:4, complete all as specified and directed. |
| 62 | M&L for applying Bituminious primer on roof surface conforming to IS-3384 bof 1986 @ 0.70 Kg/sqm and ap[plying APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3 mm thick reinforced with non-woven polyster matt laid on primed surface by torch application complete all as specified with overlap of 100 mm overlap to be thermo fushed by flame, complete all as specified and directed. |
| 63 | M&L for one coat of aluminium paint at the rate of 100 gms/sqm as per manufacturer instruction over bitumin ious layer, complete all as specified and directed. |
| 64 | Dismantling water storage tank exc 500 & n’ exc 1000 ltr capacity, complete all as specified and directed. |
| 65 | Dismantling water storage tank exc 1000 & n’ exc 2000 ltr capacity, complete all as specified and directed. |
| 66 | Dismantling water storage tank exc 2000 & n’ exc 5000 ltr capacity, complete all as specified and directed. |
| 67 | S & F for 1000 ltr capacity rotational moulded polyethene water storage tanks ÏSI Marked Embosed (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple etc all as specified in SSR part I, complete all as specified and directed. |
| 68 | S & F for 2000 ltr capacity rotational moulded polyethene water storage tanks ÏSI Marked Embosed (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple etc all as specified in SSR part I, complete all as specified and directed. |
| 69 | S & F for 4000 ltr capacity rotational moulded polyethene water storage tanks ÏSI Marked Embosed (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple etc all as specified in SSR part I, complete all as specified and directed. |
| 70 | S & F for 5000 ltr capacity rotational moulded polyethene water storage tanks ÏSI Marked Embosed (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple etc all as specified in SSR part I, complete all as specified and directed. |
| 71 | S&F in repair Ball Valves 25 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms) as fixed, complete all as specified and directed. |
| 72 | S&F in repair Ball Valves 40 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms) as fixed, complete all as specified and directed. Please Enable Macros to View BoQ information |