| 1 | 33 KV LINE |
| 2 | Supply & Erection of 13 Mtr long ST Poles 410 SP-59 complete along with pit excavation and 1/6 th of pole embedded in soil as per relevant REC standards. |
| 3 | Providing, Erection and fixing of GI Channel cross arm including clamps, braces & washers as per relevant Standards |
| 4 | Supply, Laying, Stringing and binding of 0.1 ACSR Conductor with jumpering at tension points as per relevant standards. |
| 5 | Heavy duty Pressure di-cast aluminium 630A PG-clamps suitable for 0.1 ACSR Conductor |
| 6 | Providing and fixing of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards |
| 7 | Providing and fixing of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards complete with suitable tension fittings |
| 8 | Providing and fixing of G.I. Nuts & bolts as per relevant REC standards. |
| 9 | Providing and fitting of danger plates on each pole as per relevant standards |
| 10 | Providing and fitting of Anti climbing devices with clamps on each pole as per relevant standards |
| 11 | Providing and fixing of Earthing Complete of Steel Tubular Poles by GI Pipe 40 mm or GI Rod 2.5 mtr long through GI Strip 25x3mm as per relevant REC standards. |
| 12 | Providing and painting of 13 mt S.T Poles with two coat of Red Oxide Paint of reputed make as per relevant standards |
| 13 | Providing and painting of 13 mt S.T Poles with two coats of Aluminium Paint of reputed make as per relevant standards |
| 14 | Providing and laying of Cement bottoming for 13 mtr. S.T Poles 1:2:4 mix as per REC standards (0.6 cum/pole) |
| 15 | Providing and fitting of Aluminium Jointing Sleeves as per relevant REC standards |
| 16 | Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete as per relevant standard |
| 17 | Supply & Laying of Guard Netting as per relevant standards. |
| 18 | COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATIONS (LILO) |
| 19 | G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm |
| 20 | RCC Cable Duct along with Covers framed by Angle Iron 65m65mx6m 1mx1mx1m for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures, Etc. as per REC Approved Standard Drawing. |
| 21 | 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standard drawing foundation complete job for 3.15 MVA Power Transformer. |
| 22 | 33 kV RCC Equipment foundations and Gantry foundations as per REC Approved Standard drawing ( Main Gantries, VCBs, Isolators, CTs, PIs, Las, PTs & LT Str, etc) complete job. |
| 23 | Earthing Mat using ( GI Flat 50 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd |
| 24 | Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments |
| 25 | 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd |
| 26 | Cement Conceret R/B Wall as per site requirement on the direction of concerned Engineer |
| 27 | 33KV LINE BAY & POWER XMER BAY GI STRUCTURES |
| 28 | Galvanised Steel Structures |
| 29 | Galvanised Nuts & Bolts Please Enable Macros to View BoQ information |