Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group- A |
| 3 | Group- B |
| 4 | Group- C |
| 5 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 6 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, Modular plate, suitable GI box and Earthing the point with 1.5 sq. mm FRLS PVC Insulated copper conductor single core cable etc. as required. |
| 7 | Group A |
| 8 | Group B |
| 9 | Group C |
| 10 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required. |
| 11 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 12 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 13 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in Surface/recessed pvc conduit as required. |
| 14 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 15 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 16 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 17 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 18 | 2 X 10 sq. mm+ 1 X 6 sq. mm earth wire |
| 19 | 2 X 16 sq. mm+ 1 X 6 sq. mm earth wire |
| 20 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 21 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 22 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 23 | 4 X 10 sq. mm+ 2 X 6 sq. mm earth wire |
| 24 | 4 X 16 sq. mm+ 2 X 6 sq. mm earth wire |
| 25 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and eart |
| 26 | Group A |
| 27 | Group B |
| 28 | Group C |
| 29 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way Piano type switch, phenolic Laminated suitable size MS box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 30 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc as required |
| 31 | Group A |
| 32 | Group B |
| 33 | Group C |
| 34 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 35 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 36 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 38 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 39 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 40 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 41 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 42 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 43 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 44 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 45 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 46 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 47 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 48 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 49 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 50 | Group A |
| 51 | Group B |
| 52 | Group C |
| 53 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 54 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/recessed steel/ PVC conduit. |
| 55 | 1 x 1.5 sq. mm |
| 56 | 2 x 1.5 sq. mm |
| 57 | 3 x 1.5 sq. mm |
| 58 | 4 x 1.5 sq. mm |
| 59 | 5 x 1.5 sq. mm |
| 60 | 6 x 1.5 sq. mm |
| 61 | 7 x 1.5 sq. mm |
| 62 | 8 x 1.5 sq. mm |
| 63 | 9 x 1.5 sq. mm |
| 64 | 10 x 1.5 sq. mm |
| 65 | 2 x 2.5 sq. mm |
| 66 | 3 x 2.5 sq. mm |
| 67 | 4 x 2.5 sq. mm |
| 68 | 5 x 2.5 sq. mm |
| 69 | 6 x 2.5 sq. mm |
| 70 | 7 x 2.5 sq. mm |
| 71 | 8 x 2.5 sq. mm |
| 72 | 9 x 2.5 sq. mm |
| 73 | 10 x 2.5 sq. mm |
| 74 | 2 x 4 sq. mm |
| 75 | 3 x 4 sq. mm |
| 76 | 4 x 4 sq. mm |
| 77 | 5 x 4 sq. mm |
| 78 | 6 x 4 sq. mm |
| 79 | 7 x 4 sq. mm |
| 80 | 8 x 4 sq. mm |
| 81 | 9 x 4 sq. mm |
| 82 | 10 x 4 sq. mm |
| 83 | 2 x 6 sq. mm |
| 84 | 3 x 6 sq. mm |
| 85 | 4 x 6 sq. mm |
| 86 | 5 x 6 sq. mm |
| 87 | 6 x 6 sq. mm |
| 88 | 7 x 6 sq. mm |
| 89 | 8 x 6 sq. mm |
| 90 | 9 x 6 sq. mm |
| 91 | 10 x 6 sq. mm |
| 92 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 93 | 1 Pair |
| 94 | 2 Pair |
| 95 | 3 Pair |
| 96 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 97 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 98 | 20 mm |
| 99 | 25 mm |
| 100 | 32 mm |
| 101 | 40 mm |
| 102 | 50 mm |
| 103 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 104 | 20 mm |
| 105 | 25 mm |
| 106 | 32 mm |
| 107 | 40 mm |
| 108 | 50 mm |
| 109 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 110 | 75 mm X 75 mm X 60 mm deep |
| 111 | 100 mm X 100 mm X 60 mm deep |
| 112 | 150 mm X 75 mm X 60 mm deep |
| 113 | 150 mm X 150 mm X 60 mm deep |
| 114 | 180 mm X 100 mm X 60 mm deep |
| 115 | 200 mm X 125 mm X 60 mm deep |
| 116 | 200 mm X 150 mm X 60 mm deep |
| 117 | 200 mm X 150 mm X 75 mm deep |
| 118 | 200 mm X 250 mm X 60 mm deep |
| 119 | 200 mm X 250 mm X 75 mm deep |
| 120 | 200 mm X 150 mm X 100 mm deep |
| 121 | 200 mm X 250 mm X 100 mm deep |
| 122 | 200 mm X 300 mm X 60 mm deep |
| 123 | 200 mm X 300 mm X 100 mm deep |
| 124 | 250 mm X 300 mm X 60 mm deep |
| 125 | 250 mm X 300 mm X 100 mm deep |
| 126 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 127 | 5/6 A switch |
| 128 | 2 way 5/6 A switch |
| 129 | 15/16 A switch |
| 130 | 3 pin 5/6 A socket outlet |
| 131 | 6 pin 15/16 A socket outlet |
| 132 | Telephone socket outlet |
| 133 | TV antenna socket outlet |
| 134 | Bell push |
| 135 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 136 | 5/6 A switch |
| 137 | 2 way 5/6 A switch |
| 138 | 15/16 A switch |
| 139 | 3 pin 5/6 A socket outlet |
| 140 | 6 pin 15/16 A socket outlet |
| 141 | Telephone socket outlet |
| 142 | TV antenna socket outlet |
| 143 | Bell push |
| 144 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 145 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 146 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 147 | 1 or 2 Module (75mmX75mm) |
| 148 | 3 Module (100mmX75mm) |
| 149 | 4 Module (125mmX75mm) |
| 150 | 6 Module (200mmX75mm) |
| 151 | 8 Module (125mmX125mm) |
| 152 | 12 Module (200mmX150mm) |
| 153 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 154 | 1 or 2 Module |
| 155 | 3 Module |
| 156 | 4 Module |
| 157 | 6 Module |
| 158 | 8 Module |
| 159 | 12 Module |
| 160 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 161 | Supplying and fixing metal box of 180mm X 100mm X 6Omm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 162 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 163 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 164 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 165 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 166 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 167 | Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required. |
| 168 | DELETED |
| 169 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 170 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. |
| 171 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 172 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC _ insulated, copper conductor, single core cable and earthing etc. as required. |
| 173 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 174 | Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 175 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 176 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 177 | DELETED |
| 178 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 179 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 180 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 181 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 182 | Upto 450 mm sweep |
| 183 | 510 mm sweep |
| 184 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 185 | Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required. |
| 186 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 187 | Group A |
| 188 | Group B |
| 189 | Group C |
| 190 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 191 | Group A |
| 192 | Group B |
| 193 | Group C |
| 194 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 195 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 196 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 197 | Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required. |
| 198 | MCCB,MCB &DBs |
| 199 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 200 | 32 A TP&N |
| 201 | 63 A TP&N |
| 202 | 100 A TP&N |
| 203 | 125 A TP&N |
| 204 | 160 A TP&N |
| 205 | 200 A TP&N |
| 206 | 315 A TP&N |
| 207 | 400 A TP&N |
| 208 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 209 | 100 A, 16 KA,TPMCCB |
| 210 | 125 A, 16 KA,TPMCCB |
| 211 | 150 A, 16 KA,TPMCCB |
| 212 | 200 A, 16 KA,TPMCCB |
| 213 | 200 A, 25 KA,TPMCCB |
| 214 | 250 A, 25 KA,TPMCCB |
| 215 | 250 A, 35 KA,TPMCCB |
| 216 | 315 A, 35 KA,TPMCCB |
| 217 | 400 A, 35 KA,TPMCCB |
| 218 | 500 A, 35 KA,TPMCCB |
| 219 | 630 A, 50 KA,TPMCCB |
| 220 | 800 A, 50 KA,TPMCCB |
| 221 | 100 A,30KA,FPMCCB |
| 222 | 125 A,36KA,FPMCCB |
| 223 | 200 A,36KA,FPMCCB |
| 224 | 250 A,36KA,FPMCCB |
| 225 | 250 A,50KA,FPMCCB |
| 226 | 400 A,50KA,FPMCCB |
| 227 | 630 A,50KA,FPMCCB |
| 228 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 229 | 6 way , Double door |
| 230 | 8 way , Double door |
| 231 | 12 way , Double door |
| 232 | 16 way, Double door |
| 233 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 234 | 4 way (4 + 12), Double door |
| 235 | 6 way (4 + 18), Double door |
| 236 | 8 way (4 + 24), Double door |
| 237 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 238 | 4 way (4 + 12), Double door |
| 239 | 8 way (4 + 24), Double door |
| 240 | 12 way (4 + 36), Double door |
| 241 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 242 | Single pole |
| 243 | Single pole and neutral |
| 244 | Double pole |
| 245 | Triple pole |
| 246 | Triple pole and neutral |
| 247 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 248 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 249 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 250 | 100 A |
| 251 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 252 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 253 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 254 | 2.17 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 255 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 256 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 257 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 258 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 259 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 260 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 261 | For 6 way, Double door SPN MCBDB |
| 262 | For 8 way, Double door SPN MCBDB |
| 263 | For 10 way, Double door SPN MCBDB |
| 264 | For 14 way, Double door SPN MCBDB |
| 265 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 266 | For 4 way, Double door TPN MCBDB |
| 267 | For 6 way, Double door TPN MCBDB |
| 268 | For 8 way, Double door TPN MCBDB |
| 269 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 270 | Rising Mains & Bus Trunking |
| 271 | Supplying Installation, Testing and Commissioning of on wall, testing and commissioning of following capacity rising mains made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars having current density of 130 A/ sq.cm at nominal current rating in convenient sections and suitable for 415 V, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439). |
| 272 | 200 A (S.C. rating for 1 sec - 15 kA) |
| 273 | 300 A (S.C. rating for 1 sec - 20 kA) |
| 274 | 400 A (S.C. rating for 1 sec - 25 kA) |
| 275 | 600 A (S.C. rating for 1 sec - 45 kA) |
| 276 | 800 A (S.C. rating for 1 sec - 50 kA) |
| 277 | Supplying Installation, Testing and Commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. |
| 278 | 16 A TPN |
| 279 | 32 A TPN |
| 280 | 63 A TPN |
| 281 | 100 A TPN |
| 282 | 200 A TPN |
| 283 | 315 A TPN |
| 284 | 400 A TPN |
| 285 | Supplying Installation, Testing and Commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required. |
| 286 | 16 A TPN, 2 way |
| 287 | 16 A TPN, 4 way |
| 288 | 16 A TPN, 6 way |
| 289 | 16 A TPN, 8 way |
| 290 | 32 A TPN, 2 way |
| 291 | 32 A TPN, 4 way |
| 292 | 32 A TPN, 6 way |
| 293 | 32 A TPN, 8 way |
| 294 | 63 A TPN, 2 way |
| 295 | 63 A TPN, 4 way |
| 296 | 63 A TPN, 6 way |
| 297 | 63 A TPN, 8 way |
| 298 | Supplying Installation, Testing and Commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. |
| 299 | 200 A TPN |
| 300 | 300 A TPN |
| 301 | 400 A TPN |
| 302 | 600 A TPN |
| 303 | 800 A TPN |
| 304 | Supplying, installation including suspension, testing and commissioning of following capacity bus trunking with aluminium bus bars having current density of 130 A/ sq.cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections for use on, 3 phase, 4 wire, 415 V, 50 Hz, A.C. supply including jointing of sections, flexible joints, expansion joints, bends and earthing with 2 runs of galvanised iron strips, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. |
| 305 | 800 A |
| 306 | 1000 A |
| 307 | 1250 A |
| 308 | 1400 A |
| 309 | 1600 A |
| 310 | Supplying, installation, testing and commissioning of following capacity overhead distribution bus trunking with aluminium bus bars having current density of 130 A/ sq.cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections with provision of tapping points for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply including jointing of sections, bends, earthing with 2 runs of galvanised iron strips, all installation accessories etc. as required. |
| 311 | 200 A |
| 312 | 400 A |
| 313 | Supplying, installation, testing and commissioning o f following capacity TPN tap off box / plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing overhead bus bar system complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. |
| 314 | 100 A |
| 315 | Supplying, installation on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. |
| 316 | 200 A, Isc = 15kA for 1 second |
| 317 | 315 A, Isc = 25kA for 1 second |
| 318 | 400 A, Isc = 30kA for 1 second |
| 319 | 500 A, Isc = 35kA for 1 second |
| 320 | 630 A, Isc = 50kA for 1 second |
| 321 | 800 A, Isc = 50kA for 1 second |
| 322 | 1000 A, Isc = 50kA for 1 second |
| 323 | 1250 A, Isc = 50kA for 1 second |
| 324 | Supplying, installation on wall or suspension on ceiling, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq.cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. |
| 325 | 200 A, Isc = 15kA for 1 second |
| 326 | 315 A, Isc = 25kA for 1 second |
| 327 | 400 A, Isc = 30kA for 1 second |
| 328 | 500 A, Isc = 35kA for 1 second |
| 329 | 630 A, Isc = 50kA for 1 second |
| 330 | 800 A, Isc = 50kA for 1 second |
| 331 | 1000 A, Isc = 50kA for 1 second |
| 332 | 1250 A, Isc = 50kA for 1 second |
| 333 | DELETED |
| 334 | Supplying, installation, testing & commissioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required |
| 335 | 200 A, Isc= 15kA for 1 sec |
| 336 | 315 A, Isc= 25kA for 1 sec |
| 337 | 400 A, Isc= 30kA for 1 sec |
| 338 | 500 A, Isc= 35kA for 1 sec |
| 339 | 630 A, Isc= 50kA for 1 sec |
| 340 | 800 A, Isc= 50kA for 1 sec |
| 341 | 1000 A, Isc= 50kA for 1 sec |
| 342 | 1250 A, Isc= 50kA for 1 sec |
| 343 | Supplying, installation, testing & commissioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosur e (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required |
| 344 | 125 A, Isc= 15kA for 1 sec |
| 345 | 200 A, Isc= 25kA for 1 sec |
| 346 | 250 A, Isc= 30kA for 1 sec |
| 347 | 400 A, Isc= 35kA for 1 sec |
| 348 | 500 A, Isc= 50kA for 1 sec |
| 349 | 630 A, Isc= 50kA for 1 sec |
| 350 | Supplying, installation by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required |
| 351 | 400 A, Isc= 25kA for 1 sec |
| 352 | 500 A, Isc= 30kA for 1 sec |
| 353 | 630 A, Isc= 50kA for 1 sec |
| 354 | 800 A, Isc= 50kA for 1 sec |
| 355 | 1000 A, Isc= 50kA for 1 sec |
| 356 | 1250 A, Isc= 50kA for 1 sec |
| 357 | 1600 A, Isc= 50kA for 1 sec |
| 358 | 2000 A, Isc= 50kA for 1 sec |
| 359 | 2500 A, Isc= 50kA for 1 sec |
| 360 | 3200 A, Isc= 50kA for 1 sec |
| 361 | 4000 A, Isc= 50kA for 1 sec |
| 362 | Cable Trays |
| 363 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 364 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 365 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 366 | 200 mm width X 50 mm depth X 1.6 mm thickness |
| 367 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 368 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 369 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 370 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 371 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 372 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 373 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 374 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 375 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 376 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 377 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 378 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 379 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 380 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 381 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 382 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 383 | 200 mm width X 50 mm depth X 1.6 mm thickness |
| 384 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 385 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 386 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 387 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 388 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 389 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 390 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 391 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 392 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 393 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 394 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 395 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 396 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 397 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. |
| 398 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 399 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 400 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 401 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 402 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 403 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 404 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 405 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 406 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 407 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 408 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 409 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 410 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 411 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 412 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 413 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 414 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. |
| 415 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 416 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 417 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 418 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 419 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 420 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 421 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 422 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 423 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 424 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 425 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 426 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 427 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 428 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 429 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 430 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 431 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. |
| 432 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 433 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 434 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 435 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 436 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 437 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 438 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 439 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 440 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 441 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 442 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 443 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 444 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 445 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 446 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 447 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 448 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 449 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 450 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 451 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 452 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 453 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 454 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 455 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 456 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 457 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 458 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 459 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 460 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 461 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 462 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 463 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 464 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 465 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 466 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 467 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 468 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 469 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 470 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 471 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 472 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 473 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 474 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 475 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 476 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 477 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 478 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 479 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 480 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 481 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 482 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc a s required. |
| 483 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 484 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 485 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 486 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 487 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 488 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 489 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 490 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 491 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 492 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 493 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 494 | 750 mm width X 62.5 mm depth X 2.0 mm thickness |
| 495 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 496 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 497 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 498 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 499 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 500 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 501 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 502 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 503 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 504 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 505 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 506 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 507 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 508 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 509 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 510 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 511 | 750mm width X 62.5 mm depth X 2 mm thickness |
| 512 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 513 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 514 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 515 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 516 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Reducer\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 517 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 518 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 519 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 520 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 521 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 522 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 523 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 524 | 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 525 | 375 mm width X 62.5 mm depth X 2.0 mm thickness |
| 526 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 527 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 528 | 750mm width X 62.5 mm depth X 2 mm thickness |
| 529 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 530 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 531 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 532 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 533 | Earthing |
| 534 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 535 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 536 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt ) as required. |
| 537 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 538 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt) as required. |
| 539 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 540 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 541 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt , spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 542 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 543 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 544 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 545 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 546 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 547 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 548 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 549 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 550 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 551 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 552 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 553 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 554 | LIGHTNING CONDUCTOR |
| 555 | DELETED |
| 556 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 557 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. |
| 558 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 559 | DELETED |
| 560 | DELETED |
| 561 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 562 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 563 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 564 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 565 | DELETED |
| 566 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 567 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 568 | Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 569 | Lighting Controls |
| 570 | Supplying, Installation, Testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 meter and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 571 | Supplying, Installation, Testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high performance, regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 572 | Supplying, Installation, Testing and commissioning of Microwave technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 meter and for 5m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 573 | Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 574 | 01 output per phase and suitable for single phase supply |
| 575 | 02 output per phase and suitable for single phase supply |
| 576 | 03 output(1output per phase) and suitable for three phase supply |
| 577 | LED LIGHT |
| 578 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Su pplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protec tion ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim |
| 579 | 5 - 7 watt |
| 580 | 8 - 10 watt |
| 581 | 12 -15 watt |
| 582 | 18 watt |
| 583 | 22 watt |
| 584 | 30 watt |
| 585 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Su pplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CC T 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 586 | 5 - 7 watt |
| 587 | 8 - 10 watt |
| 588 | 12 -15 watt |
| 589 | 18 watt |
| 590 | 22 watt |
| 591 | 30 watt |
| 592 | LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Su pplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI > 80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 593 | 5 - 7 watt |
| 594 | 8 - 10 watt |
| 595 | 12 -15 watt |
| 596 | 18 watt |
| 597 | 22 watt |
| 598 | 30 watt |
| 599 | LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ). Su pplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.9 5, IP20, CRI > 80, UGR (Unified Glare Rating ) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. S ystem lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 600 | 5 - 7 watt |
| 601 | 8 - 10 watt |
| 602 | 12 -15 watt |
| 603 | 18 watt |
| 604 | 22 watt |
| 605 | 30 watt |
| 606 | LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Su pplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer- in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 607 | 5 - 7 watt |
| 608 | 8 - 10 watt |
| 609 | 12 -15 watt |
| 610 | 18 watt |
| 611 | 22 watt |
| 612 | 30 watt |
| 613 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Sup plying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 614 | 15 watt |
| 615 | 18 watt |
| 616 | 22 watt |
| 617 | 36 watt |
| 618 | 40 watt |
| 619 | 45 watt |
| 620 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 621 | 15 watt |
| 622 | 18 watt |
| 623 | 22 watt |
| 624 | 36 watt |
| 625 | 40 watt |
| 626 | 45 watt |
| 627 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Su pplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 628 | 15 watt |
| 629 | 18 watt |
| 630 | 22 watt |
| 631 | 36 watt |
| 632 | 40 watt |
| 633 | 45 watt |
| 634 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 635 | 15 watt |
| 636 | 18 watt |
| 637 | 22 watt |
| 638 | 36 watt |
| 639 | 40 watt |
| 640 | 45 watt |
| 641 | LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Su pplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as 44 required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 642 | 15 watt |
| 643 | 18 watt |
| 644 | 22 watt |
| 645 | 36 watt |
| 646 | 40 watt |
| 647 | 45 watt |
| 648 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 649 | 15 watt |
| 650 | 18 watt |
| 651 | 22 watt |
| 652 | 36 watt |
| 653 | 40 watt |
| 654 | 45 watt |
| 655 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Su pplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 8.9.1 18- 22 WattEach 681 |
| 656 | 24 -26watt |
| 657 | 36 watt |
| 658 | 40 watt |
| 659 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 660 | 18- 22 Watt |
| 661 | 24 -26watt |
| 662 | 36 watt |
| 663 | 40 watt |
| 664 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K 46 (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. a s required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 665 | 18- 22 Watt |
| 666 | 24 -26watt |
| 667 | 36 watt |
| 668 | 40 watt |
| 669 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 670 | 18- 22 Watt |
| 671 | 24 -26watt |
| 672 | 36 watt |
| 673 | 40 watt |
| 674 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 675 | 18- 22 WattEach |
| 676 | 24 -26watt |
| 677 | 36 watt |
| 678 | 40 watt |
| 679 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 680 | 18- 22 WattEach |
| 681 | 24 -26watt |
| 682 | 36 watt |
| 683 | 40 watt |
| 684 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Su pplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range - 5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 4861000-3-2 , P. F.≥0.95, IP -66,IK-10, CRI > 70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 685 | 10 watt |
| 686 | 14 watt |
| 687 | 15 watt |
| 688 | 18 watt |
| 689 | 20 watt |
| 690 | 24 watt |
| 691 | 25 watt |
| 692 | 30 watt |
| 693 | 36 watt |
| 694 | 40 watt |
| 695 | 45 watt |
| 696 | 50 watt |
| 697 | 72 watt |
| 698 | 90 watt |
| 699 | 100 watt |
| 700 | 120 watt |
| 701 | 150 watt |
| 702 | 180 watt |
| 703 | 200 watt |
| 704 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Su pplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range - 5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP -66,IK-10, CRI > 70, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 705 | 10 watt |
| 706 | 14 watt |
| 707 | 15 watt |
| 708 | 18 watt |
| 709 | 20 watt |
| 710 | 24 watt |
| 711 | 25 watt |
| 712 | 30 watt |
| 713 | 36 watt |
| 714 | 40 watt |
| 715 | 45 watt |
| 716 | 50 watt |
| 717 | 72 watt |
| 718 | 90 watt |
| 719 | 100 watt |
| 720 | 120 watt |
| 721 | 150 watt |
| 722 | 180 watt |
| 723 | 200 watt |
| 724 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Sup plying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range - 5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP -66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 725 | 10 watt |
| 726 | 14 watt |
| 727 | 15 watt |
| 728 | 18 watt |
| 729 | 20 watt |
| 730 | 24 watt |
| 731 | 25 watt |
| 732 | 30 watt |
| 733 | 36 watt |
| 734 | 40 watt |
| 735 | 45 watt |
| 736 | 50 watt |
| 737 | 72 watt |
| 738 | 90 watt |
| 739 | 100 watt |
| 740 | 120 watt |
| 741 | 150 watt |
| 742 | 180 watt |
| 743 | 200 watt |
| 744 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Su pplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range - 5 0C to 52, 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP -66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be o f relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 745 | 50 watt |
| 746 | 70 watt |
| 747 | 100 watt |
| 748 | 150 watt |
| 749 | 200 watt |
| 750 | 250 watt |
| 751 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Su pplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range - 5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP -66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5 , Maximum power consumption should not more than the specified rating and Fixture shall be o f relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 yea r OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 752 | 50 watt |
| 753 | 70 watt |
| 754 | 100 watt |
| 755 | 150 watt |
| 756 | 200 watt |
| 757 | 250 watt |
| 758 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Su pplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range - 5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP -66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 759 | 50 watt |
| 760 | 70 watt |
| 761 | 100 watt |
| 762 | 150 watt |
| 763 | 200 watt |
| 764 | 250 watt |
| 765 | LED Smart Street light fixture, powder coated pressure die cast aluminium (System. System lumen efficacy ≥105 and <120 l m/Watt) Sup plying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -15 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP -66,IK- 08, CRI >70, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Smart inbuilt controller shall have following features. 1.Control and monitor LED luminaries with bi directional control ( Status, Fault, Alarm, dimming level, wattage, energy) 2.to measure voltage, current, power, power facto r, apparent energy, active energy, operating hours. 3.Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR). 4.Wi-Fi LoRA/Zigbee/Powerline with etherne t network based IOT feature as per site requiremen t or engineer in charge. 5.should be controlled through auto/ manual 6.Programmable level of not less than 48 differen t light intensity settings, 7. inbuilt repeater & relay signals function to othe r controllers |
| 766 | 45 watt |
| 767 | 50 watt |
| 768 | 72 watt |
| 769 | 90 watt |
| 770 | 100 watt |
| 771 | 120 watt |
| 772 | 150 watt |
| 773 | 180 watt |
| 774 | 200 watt |
| 775 | LED Smart Street light fixture, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140- 270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP -66,IK- 08, CRI >70, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Smart inbuilt controller shall have following features. 1.Control and monitor LED luminaries with bi directional control( Status, Fault, Alarm, dimming level, wattage, energy) 2. To measure voltage, current, power, power factor, apparent energy, active energy, operating hours. 3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR). 4. Wi-Fi LoRA/Zigbee/Powerline with ethernet network based IOT feature as per site requirement or engineer in charge. 5. Should be controlled through auto/ manual 6. Programmable level of not less than 48 different light intensity settings, 7. Inbuilt repeater & relay signals function to other controllers |
| 776 | 45 watt |
| 777 | 50 watt |
| 778 | 72 watt |
| 779 | 90 watt |
| 780 | 100 watt |
| 781 | 120 watt |
| 782 | 150 watt |
| 783 | 180 watt |
| 784 | 200 watt |
| 785 | LED Smart Street light fixture, powder coated pressure die cast aluminium (System. System lumen efficacy >135 lm/Watt). Sup plying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P.F.≥0.95, IP -66,IK- 08, CRI >70, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 900C) Sm art inbuilt controller shall have following features. 1.Control and monitor LED luminaries with bi directional control( Status, Fault, Alarm, dimming level, wattage, energy) 2.to measure voltage, current, power, power factor, apparent energy, active energy, operating hours 3.Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR). 4.Wi-Fi LoRA/Zigbee/Powerline with ethernet network based IOT feature as per site requirement or engineer in charge. 5.should be controlled through auto/ manual 6.Programmable level of not less than 48 different light intensity settings, 7.inbuilt repeater & relay signals function to other controllers |
| 786 | 45 watt |
| 787 | 50 watt |
| 788 | 72 watt |
| 789 | 90 watt |
| 790 | 100 watt |
| 791 | 120 watt |
| 792 | 150 watt |
| 793 | 180 watt |
| 794 | 200 watt |
| 795 | Solar outdoor LED light |
| 796 | Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 20 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%), Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) Charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, With Lithium- Iron Phosphate Battery (LiFePO4),charging time 6-8 hours, Battery backup time 12 hours (minimum), LED fixture 20 watt, Input voltage: 12V DC, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI > 70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPR 15, lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K / (As per American National Standard Institute (ANSI Bin)), life time (LED,Driver & electrical circuitry) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 20 Watt (System lumen efficacy >120 lm/Watt) |
| 797 | Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 30 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%), Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, With Lithium- Iron Phosphate Battery (LiFePO4), charging time 8- 10 hours, Battery backup time 12 hours (minimum), LED fixture watt 30 watt, Input voltage: 12V DC , Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPER 15 A, lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K (As per American National Standard Institute (ANSI Bin)) , life time (LED,Driver & electrical circuitary) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 30 Watt (System lumen efficacy >120 lm/Watt) |
| 798 | Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 35 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%),, Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) Charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, with Lithium-Iron Phosphate Battery (LiFePO4), charging time 8-10 hours, Battery backup time 12 hours (minimum), LED fixture watt 35 watt, Input voltage: 12V DC , Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPR 15 , lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K (As per American National Standard Institute (ANSI Bin)), life time (LED, Driver & electrical circuitry) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 35 Watt (System lumen efficacy >120 lm/Watt) |
| 799 | BLDC Fan |
| 800 | Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 801 | 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) |
| 802 | 1050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum) |
| 803 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 804 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 805 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessorie s including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 806 | 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) |
| 807 | 1050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum) |
| 808 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 809 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 810 | MV CABLE LAYING |
| 811 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 812 | Upto 35 sq. mm |
| 813 | Above 35 sq. mm and upto 95 sq. mm |
| 814 | Above 95 sq. mm and upto 185 sq. mm |
| 815 | Above 185 sq. mm and upto 400 sq. mm |
| 816 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 817 | Upto 35 sq. mm |
| 818 | Above 35 sq. mm and upto 95 sq. mm |
| 819 | Above 95 sq. mm and upto 185 sq. mm |
| 820 | Above 185 sq. mm and upto 400 sq. mm |
| 821 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 822 | Upto 35 sq. mm |
| 823 | Above 35 sq. mm and upto 95 sq. mm |
| 824 | Above 95 sq. mm and upto 185 sq. mm |
| 825 | Above 185 sq. mm and upto 400 sq. mm |
| 826 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 827 | Upto 35 sq. mm |
| 828 | Above 35 sq. mm and upto 95 sq. mm |
| 829 | Above 95 sq. mm and upto 185 sq. mm |
| 830 | Above 185 sq. mm and upto 400 sq. mm |
| 831 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 832 | Upto 35 sq. mm |
| 833 | Above 35 sq. mm and upto 95 sq. mm |
| 834 | Above 95 sq. mm and upto 185 sq. mm |
| 835 | Above 185 sq. mm and upto 400 sq. mm |
| 836 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 837 | Upto 35 sq. mm |
| 838 | Above 35 sq. mm and upto 95 sq. mm |
| 839 | Above 95 sq. mm and upto 185 sq. mm |
| 840 | Above 185 sq. mm and upto 400 sq. mm |
| 841 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 842 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 843 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 844 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 845 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 846 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 847 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 848 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 849 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 850 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 851 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 852 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 853 | MV Cable Jointing & End Termination |
| 854 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 855 | 2 X 6 sq. mm (19mm) |
| 856 | 2 X 10 sq. mm (19mm) |
| 857 | 2 X 16 sq. mm (22mm) |
| 858 | 2 X 25 sq. mm (22mm) |
| 859 | 2 X 35 sq. mm (25mm) |
| 860 | 2 X 50 sq. mm (28mm) |
| 861 | 3 X 10 sq. mm (22mm) |
| 862 | 3 X 16 sq. mm (25mm) |
| 863 | 3 X 25 sq. mm (25mm) |
| 864 | 3 X 35 sq. mm (28mm) |
| 865 | 3 X 50 sq. mm (32mm) |
| 866 | 3 X 70 sq. mm (35mm) |
| 867 | 3 X 95 sq. mm (38mm) |
| 868 | 3 X 120 sq. mm (45mm) |
| 869 | 3 X 150 sq. mm (50mm) |
| 870 | 3 X 185 sq. mm (57mm) |
| 871 | 3 X 225 sq. mm (62mm) |
| 872 | 3 X 240 sq. mm (62mm) |
| 873 | 3 X 300 sq. mm (70mm) |
| 874 | 3½ X 25 sq. mm (28mm) |
| 875 | 3½ X 35 sq. mm (32mm) |
| 876 | 3½ X 50 sq. mm (35mm) |
| 877 | 3½ X 70 sq. mm (38mm) |
| 878 | 3½ X 95 sq. mm (45mm) |
| 879 | 3½ X 120 sq. mm (45mm) |
| 880 | 3½ X 150 sq. mm (50mm) |
| 881 | 3½ X 185 sq. mm (57mm) |
| 882 | 3½ X 225 sq. mm (62mm) |
| 883 | 3½ X 240 sq. mm (62mm) |
| 884 | 3½ X 300 sq. mm (70mm) |
| 885 | 3½ X 400 sq. mm (82mm) |
| 886 | 4 X 10 sq. mm (25mm) |
| 887 | 4 X 16 sq. mm (28mm) |
| 888 | 4 4 X 25 sq. mm (28mm) |
| 889 | 4 X 35 sq. mm (32mm) |
| 890 | 4 X 50 sq. mm (35mm) |
| 891 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 892 | 2 X 16 sq. mm |
| 893 | 2 X 25 sq. mm |
| 894 | 2 X 35 sq. mm |
| 895 | 2 X 50 sq. mm |
| 896 | 3 X 16 sq. mm |
| 897 | 3 X 25 sq. mm |
| 898 | 3 X 35 sq. mm |
| 899 | 3 X 50 sq. mm |
| 900 | 3 X 70 sq. mm |
| 901 | 3 X 95 sq. mm |
| 902 | 3 X 120 sq. mm |
| 903 | 3 X 150 sq. mm |
| 904 | 3 X 185 sq. mm |
| 905 | 3 X 225 sq. mm |
| 906 | 3 X 240 sq. mm |
| 907 | 3 X 300 sq. mm |
| 908 | 3½ X 25 sq. mm |
| 909 | 3½ X 35 sq. mm |
| 910 | 3½ X 50 sq. mm |
| 911 | 3½ X 70 sq. mm |
| 912 | 3½ X 95 sq. mm |
| 913 | 3½ X 120 sq. mm |
| 914 | 3½ X 150 sq. mm |
| 915 | 3½ X 185 sq. mm |
| 916 | 3½ X 225 sq. mm |
| 917 | 3½ X 240 sq. mm |
| 918 | 3½ X 300 sq. mm |
| 919 | 3½ X 400 sq. mm |
| 920 | 4 X 16 sq. mm |
| 921 | 4 X 25 sq. mm |
| 922 | 4 X 35 sq. mm |
| 923 | 4 X 50 sq. mm |
| 924 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 925 | 2 X 16 sq. mm |
| 926 | 2 X 25 sq. mm |
| 927 | 2 X 35 sq. mm |
| 928 | 2 X 50 sq. mm |
| 929 | 3 X 16 sq. mm |
| 930 | 3 X 25 sq. mm |
| 931 | 3 X 35 sq. mm |
| 932 | 3 X 50 sq. mm |
| 933 | 3 X 70 sq. mm |
| 934 | 3 X 95 sq. mm |
| 935 | 3 X 120 sq. mm |
| 936 | 3 X 150 sq. mm |
| 937 | 3 X 185 sq. mm |
| 938 | 3 X 225 sq. mm |
| 939 | 3 X 240 sq. mm |
| 940 | 3 X 300 sq. mm |
| 941 | 3½ X 25 sq. mm |
| 942 | 3½ X 35 sq. mm |
| 943 | 3½ X 50 sq. mm |
| 944 | 3½ X 70 sq. mm |
| 945 | 3½ X 95 sq. mm |
| 946 | 3½ X 120 sq. mm |
| 947 | 3½ X 150 sq. mm |
| 948 | 3½ X 185 sq. mm |
| 949 | 3½ X 225 sq. mm |
| 950 | 3½ X 240 sq. mm |
| 951 | 3½ X 300 sq. mm |
| 952 | 3½ X 400 sq. mm |
| 953 | 4 X 16 sq. mm |
| 954 | 4 X 25 sq. mm |
| 955 | 4 X 35 sq. mm |
| 956 | 4 X 50 sq. mm |
| 957 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 958 | 2 X 16 sq. mm |
| 959 | 2 X 25 sq. mm |
| 960 | 2 X 35 sq. mm |
| 961 | 2 X 50 sq. mm |
| 962 | 3 X 16 sq. mm |
| 963 | 3 X 25 sq. mm |
| 964 | 3 X 35 sq. mm |
| 965 | 3 X 50 sq. mm |
| 966 | 3 X 70 sq. mm |
| 967 | 3 X 95 sq. mm |
| 968 | 3 X 120 sq. mm |
| 969 | 3 X 150 sq. mm |
| 970 | 3 X 185 sq. mm |
| 971 | 3 X 225 sq. mm |
| 972 | 3 X 240 sq. mm |
| 973 | 3 X 300 sq. mm |
| 974 | 3½ X 25 sq. mm |
| 975 | 3½ X 35 sq. mm |
| 976 | 3½ X 50 sq. mm |
| 977 | 3½ X 70 sq. mm |
| 978 | 3½ X 95 sq. mm |
| 979 | 3½ X 120 sq. mm |
| 980 | 3½ X 150 sq. mm |
| 981 | 3½ X 185 sq. mm |
| 982 | 3½ X 225 sq. mm |
| 983 | 3½ X 240 sq. mm |
| 984 | 3½ X 300 sq. mm |
| 985 | 3½ X 400 sq. mm |
| 986 | 4 X 16 sq. mm |
| 987 | 4 X 25 sq. mm |
| 988 | 4 X 35 sq. mm |
| 989 | 4 X 50 sq. mm |
| 990 | Pole Erection |
| 991 | Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. |
| 992 | Above 4.5 Meter and upto 6.5 Meter |
| 993 | Above 6.5 Meter and upto 8.0 Meter |
| 994 | Above 8.0 Meter and upto 11.0 Meter |
| 995 | Above 11.00 metre and upto 13.00 Meter |
| 996 | Erection of RCC/ PCC pole strut in brick ballast and ramming the foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 997 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 998 | Above 4.5 Meter and upto 6.5 Meter |
| 999 | Above 6.5 Meter and upto 8.0 Meter |
| 1000 | Above 8.0 Meter and upto 10.0 Meter |
| 1001 | Above 10.00 Meter and upto 12.00 Meter |
| 1002 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 1003 | Providing and making steel pole collar with cement concrete (1 cement: 3 coarse sand: 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) |
| 1004 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 1005 | 32 mm dia |
| 1006 | 40 mm dia |
| 1007 | MV Over Head Line Work |
| 1008 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 1009 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 1010 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.Each |
| 1011 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 1012 | Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required. |
| 1013 | Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required. |
| 1014 | Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required. |
| 1015 | Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener), 7/ 3.15mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required. |
| 1016 | Erection of stay set complete (galvanised) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 1017 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required . |
| 1018 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required . |
| 1019 | Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required. |
| 1020 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required. |
| 1021 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required. |
| 1022 | Erection of galvanised 'D' iron clamps and insulator on pole as required. |
| 1023 | Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required . |
| 1024 | Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required . |
| 1025 | Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required . |
| 1026 | Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required . |
| 1027 | Erection of LV/MV shackle/pin insulator etc. as required. |
| 1028 | Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required. |
| 1029 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. |
| 1030 | Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required. |
| 1031 | Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required. |
| 1032 | Erection of G.I. Wire No. 8 SWG including binding etc. as required. |
| 1033 | Erection of hexagonal type guard as required. |
| 1034 | Erection of ring type guard as required. |
| 1035 | Erection of cradle guard as required. |
| 1036 | Supplying and erection of 15 A aerial fuse complete as requir ed. |
| 1037 | Supplying and erection of 30 A aerial fuse complete as required. |
| 1038 | Erection of aerial fuse as required. |
| 1039 | Supplying and fixing MV horn gap lightening arrestor as required. |
| 1040 | Fixing of MV lightning arrestor as required. |
| 1041 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 1042 | Providing and fixing 50 mm dia X 3.2 metres G.I. pipe (including accessories) complete with 50 mm X 50 mm X 6 mm angle iron bracket on wall and 75 mm X 90 mm shackle insulator with straps for house service connection including painting the angle and flat iron with primer and finish paint etc. as required. |
| 1043 | Providing and fixing 50 mm dia X 5.6 metres G.I. pipe (including accessories) complete with 50 mm X 50 mm X 6 mm angle iron cross arm and 40 mm X 3mm M.S. flat iron clamps bends for guard wire, 75 mm X 90 mm shackle insulator and straps, 7/ 3.15 mm G.I. wire stay set for house service connection including painting the angle and flat iron with primer and finish paint etc. as required. |
| 1044 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 1045 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 1046 | Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 1047 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. |
| 1048 | Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required. |
| 1049 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. |
| 1050 | HV Over Head Line Work |
| 1051 | Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 1052 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 1053 | Supplying and erection of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 1054 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 1055 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 1056 | Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required. |
| 1057 | Supplying and erection of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 1058 | Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required. |
| 1059 | Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required. |
| 1060 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 1061 | Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 1062 | Erection of disc/ pin insulator for 11 KV over head lines as required. |
| 1063 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 1064 | Supplying and erection of galvanised stay set for 33 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 33 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 1065 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 33 KV over head line conductor complete with 50 mm X 6mm flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required. |
| 1066 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 33 KV over head line conductors complete with 50 mm X 50 mm X 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required. |
| 1067 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 33 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 1068 | Supplying and erection of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre), pole top bracket/ cross arm for single 33 KV over head line conductor complete with 50 mm X 6 mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 1069 | Supplying and erection of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre) cross arm for two wire 33 KV over head line conductors complete with 50 mm X 50 mm X 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins/ fittings, bolts, nuts, washers etc and painting with primer and finish paint as required |
| 1070 | Supplying and erection of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre) V shape cross arm for two 33 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required . |
| 1071 | Supplying and erection of two lengths of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre) double pole cross arm for three wire 33 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts, washers etc and painting with primer and finish paint as required . |
| 1072 | Supplying and erection of a set of cross bracing frame work for 33 KV over head line double pole structure having four members fabricated out of 65 mm X 65 mm X 6 mm angle iron to form a rectangle of minimum size 2400 mm width X 2800 mm height complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required . |
| 1073 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 1074 | Supplying and erection of a set of three 11 KV disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 1075 | Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 1076 | Misc. Work |
| 1077 | Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 1078 | Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. |
| 1079 | Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres. |
| 1080 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 1081 | Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying. |
| 1082 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. |
| 1083 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 1084 | Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 1085 | Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 1086 | Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as require d (excluding reinforcement). |
| 1087 | Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 1088 | Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels. |
| 1089 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 1090 | 50 mm dia |
| 1091 | 80 mm dia |
| 1092 | 100 mm dia |
| 1093 | 150 mm dia |
| 1094 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 1095 | 100 mm dia |
| 1096 | 150 mm dia |
| 1097 | 250 mm dia |
| 1098 | 300 mm dia |
| 1099 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 1100 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 1101 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1102 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 1103 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 1104 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 1105 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 1106 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 1107 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1108 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 1109 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 1110 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 1111 | P/F MS fan clamps of 16 mm dia M.S. bar, bent to shape with Hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete (DSR Civil-2014 item no. 10.17 ) |
| 1112 | ii) Providing and fixing circular/Hexagonal G.I. Box for ceiling fan clamps, of internal dia 140 mm, 73 mm height, top LID of 1.5 mm thick G.I. sheet with its top surface hacked for proper bonding, top LID shall be screwed into the G.I. box by means of 3.3 mm dia rounded screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shap as per standard drawing. (DSR Civil-2014 item no. 10.18 ) |
| 1113 | iii) Making hole for installation of exhaust fan of size upto 450mm sweep by demolishing brick work manually/by mechanical means including disposal of malba within 50 meters lead and making good the wall by plastering etc. as required. (DSR Civil-2014 item no. 15.7.4 and 13.1.2 ) |
| 1114 | iv) Painting with one or more coat of synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. (DSR Civil-2014 item no. 14.54 ) |
| 1115 | v) Painting with one or more coat of aluminum paint of approved brand and manufacture to give an even shade. (DSR Civil-2014 item no. 14.55) |
| 1116 | vi) Painting with one or more coat of black anticorrosive bituminous paint of approved brand & manufacturer to give an even shade (DSR civil 2014- Item no. 14.56) |
| 1117 | vii) Re-lettering with black Japan paint of approved brand and manufacture. (DSR Civil-2014 item no. 14.60) |
| 1118 | Façade Lighting |
| 1119 | LED floodlight Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB/ RGBWW/ RGBNW/RGBA/RGBW (as per site requirement) Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing, powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 5/10/15/20/25/30/40/45/60 degree. Luminaire should have efficacy of minimum 35 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime of complete luminaire(LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories, Integral male/female water proof connectors IP 68 etc. as required.The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, RoHS Compliance. |
| 1120 | LED Linear Profile (AC) Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/RGBNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree. Luminaire should have efficacy of minimum 40 lm/W for RGB/ RGBNW/ RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories , Integral male/female water proof connectors of IP68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, Rohs Compliance. Wattage per meter |
| 1121 | LED Linear Profile (DC) Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/RG BNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/ EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree. Luminaire should have efficacy of minimum 40 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum siz e 1.5sqmm connection cables and accessories , Integral male/female water proof connectors of IP68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, Rohs Compliance. Wattage per meter |
| 1122 | RGB LED Strip Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/ RGBNW/ RGBA/RGBW suitable for exterior use having IP68 rating (as per site requirement). Flexible light strip of 5 mtr standard length with 12-15 Watt per meter. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. Minimum System lumens 450 lumens/meter and System Lumen Efficacy > 30lm/w. Luminaire light beam spread - 100-110°, The Strip should have IP 68 protection and is offered IP 68 rated connectors to join the LED Strips in continuity. The luminaire must be offered with Aluminium channel for mounting the strip lights. The product should be complete with all accessories and Driver. Lifetime of complete luminaire (LED, Driver, Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC, Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79. report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance along with CE certificate. |
| 1123 | Controller |
| 1124 | Supplying Installation, Testing and Commissioning of DMX Controller for the system including address writer and programming the DMX controller with the suitable designs as decided by the Engineer- in-charge/client department ( not less than 10 nos designs) and all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet. Dmx controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. It’s must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presents and also have provision of keypad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C.OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10/11. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad /Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta clamp to mount on wall with data enablers and splitters as required. To be provided with IP 66 enclosure if installed in external environment. |
| 1125 | Splitter |
| 1126 | Supplying Installation, Testing and Commissioning of DMX Splitter with Input Voltage range : 190-240V AC, Power Consumption 5W max. Housing is made of CRCA with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature - 30°C to +55°C, 8 Output with 3pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 8 separate output channels. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment etc., complete as required. |
| 1127 | Supplying Installation, Testing and Commissioning of RDM -6Wall Splitter, should be able to provide 6- output DMX/RDM splitter with DMX/RDM pass- through supporting bi-directional communications for discovery, addressing and DMX control of Ethernet/DMX products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6x32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Surface or DIN-rail mountable, Isolated DMX/RDM Input/Outputs, Automatic switching between DMX and RDM mode for auto-discovery, Environment-IP20, Interior applications, Finish/Color- Polycarbonate, Certification: CE Certified. DMX Splitter/Booster etc. as required. |
| 1128 | Signal Amplifier |
| 1129 | Supplying Installation, Testing and Commissioning of Signal Amplifier to boost the Signal, IP 65 rated module to enhance the depleting DMX Signals, should have IP 66/67 rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic circuit for functioning. No external LED driver needed etc., complete as required. |
| 1130 | DMX decoder |
| 1131 | Supplying, installation, testing and commissioning of high quality DMX decoder, Power Input : DC 24V etc complete as required. |
| 1132 | Connector |
| 1133 | Supplying and Fixing of IP65 \\"I\\" power connectors having 3/4 pole cable connector, chuck type strain relief, Current rating 20 A rms continuous, Easy and extremely precise locking system \\"Quick Lock\\" High impact materials - long-lasting and reliable etc complete as required. |
| 1134 | Supplying and Fixing of IP65 \\"I\\" DMX connectors having 3/5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability, etc complete as required. |
| 1135 | Supplying and Fixing of 5 pin XLR Male/Female connectors having 5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability etc as required. |
| 1136 | Processor |
| 1137 | Supplying Installation Testing and Commissioning of push button type keypad with 10 buttons. Each button is programmable up to 16 scenarios. Also has got two dry-contact input to trigger any preset scene, etc as required |
| 1138 | Fountain |
| 1139 | Supplying, Installation, Testing and Commissioning of Nozzle made with gunmetal Grade Geyser jet 100mmı with adjustable nozzle for height adjustment of the fountain etc. Complete as required. |
| 1140 | Supplying, Installation Testing Commissioning of Fixing of 40 mm dia Bubbler Jet Nozzles in SS 304 Gr to produce water effect etc. complete as required. |
| 1141 | Supplying, Installation, Testing and Commissioning of 40 mm dia SS Difuser Nozzles in SS 304 Gr to produce water effect etc. complete as required. |
| 1142 | Supplying, Installation, Testing and Commissioning of Stainless steel 304 gr. Comet effect nozzle with compatible Digitally controlled pump to produce desirable effects with 40 mm dia and 20 mm orifice nozzle etc. complete as required as per direction given by engineer in charge |
| 1143 | Supplying, Installation, Testing and Commissioning of Single Jet Crown Nozzles Complete with ball joint for 15 Degree pivoting made of brass with Nickle plating,flow straightner in following size . Height of water stream upto 10 mtrs. etc. complete as required. |
| 1144 | 15 mm internal threaded with 6 mm orifice. |
| 1145 | 15 mm internal threaded with 8 mm orifice. |
| 1146 | 15 mm internal threaded with 10 mm orifice. |
| 1147 | 25 mm internal threaded with 12 mm orifice. |
| 1148 | 25 mm internal threaded with 14 mm orifice. |
| 1149 | 40 mm internal threaded with 17 mm orifice. |
| 1150 | 40 mm internal threaded with 20 mm orifice. |
| 1151 | Supplying, Installation, Testing and Commissioning of Eco Cluster Nozzle made of stainless steel with inlet dia 40 mm and 21 nos Single jets to create 38 mm dia full jet for height 10 mtr water level in depended etc. complete as required. |
| 1152 | Supplying Installation, Testing and Commissioning of Eco Cluster Nozzle made of stainless steel with inlet dia 80 mm and 64 nos Single jets to Create 67 mm dia full jet for fountain height 10 mtr water level in depended etc. complete as required. |
| 1153 | Supplying, Installation, Testing and Commissioning of Central hollow jet65 mm dia for achieving maximum height of 20 mtrs to produce clear full jet stable in wind water level independent etc. complete as required. |
| 1154 | Supplying, Installation, Testing and Commissioning of Lava bell nozzle for producing transparent water pattern with adjustable ball dia made out of SS 304 Gr./Brass of following Size etc. complete as required. |
| 1155 | 15 mm Dia inlet 290 mm long |
| 1156 | 25 mm Dia inlet 330 mm long |
| 1157 | 25 mm Dia inlet 488 mm long |
| 1158 | 25 mm Dia inlet 636 mm long |
| 1159 | Supplying, Installation, Testing and Commissioning of Foam jet High contrast for producing high contrast/foam effect to extensively wind stable, water level independent moc Brass /SS 316L of following size etc. complete as required. |
| 1160 | 25 mm Dia inlet 32 mm orifice 160 mm long. |
| 1161 | 25 mm Dia inlet 50 mm orifice 180 mm long. |
| 1162 | 40 mm Dia inlet 50 mm orifice 180 mm long. |
| 1163 | Supplying, Installation, Testing and Commissioning of 20 mm nylon rope all the accessories Floater Grit Clamping both sides etc. complete as required. |
| 1164 | Supplying, Installation, Testing and Commissioning of fixing of Suction Screen stainer made of ABS to be fitted in suction to protect the pump from enrty of external materials etc. complete as required. |
| 1165 | Supplying, Installation, Testing and Commissioning of 100 mm Dia Debris Collection Strainer in Stainless steel 304 gr etc. complete as reqd. |
| 1166 | Supplying, Installation, Testing and Commissioning of 400 mm Dia wide SS Overflow Skimmer in Stainless steel 304 gr with front openable fitted debris trapping mesh with outlet size of 65mm Dia for fixing in wall etc. Complete as reqd. |
| 1167 | Supplying, Installation, Testing and Commissioning of 300x300 mm Dia Main Drain in SS 304 Gr with perforations to disallow foreign material with top openable for maintenance etc. complete as required. |
| 1168 | Supplying, Installation, Testing and Commissioning of ISI Marked openwell submersible pump set contain with stainless steel shaft and cast iron/SS body, the pump shall be designed to prevent over loading and having dynamically balanced rotating parts etc. the pump capable of delivering following capacities discharge at suitable head and lowering the pumps in water bodies and suitable for operation on 415V(+- 10%), 3-phase AC supply including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet including connection, interconnection ,supports etc. as required. suitable for 900LPM at 25 Mtrs Head etc. complete as required. |
| 1169 | Supplying, Installation, Testing and Commissioning of ISI Marked vertical Multi Stage submersible pump set contain with stainless steel shaft and cast iron/SS body, the pump shall be designed to prevent over loading and having dynamically balanced rotating parts etc. the pump capable of delivering following capacities discharge at suitable head and lowering the pumps in water bodies and suitable for operation on 415V(+-10%), 3- phase AC supply including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. suitable for 1200LPM at14 mtr. head etc. complete as required. |
| 1170 | Supplying, Installation, Testing and Commissioning of three phase open well ISI Marked submersible pumpset of 1.5H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compatible for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections etc. complete of suitable head and discharge etc. complete as required. |
| 1171 | Supplying, Installation, Testing and Commissioning of three phase openwell ISI Marked submersible pump set of 7.5 H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compatible for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections etc. complete as required. |
| 1172 | Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal gate valve (Screwed type) on the existing pipeline, including testing & Commissioning etc. complete as required.. |
| 1173 | 80 mm dia |
| 1174 | 50 mm dia |
| 1175 | Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal Horizontal Non Return valve ( screwed type ) on the existing pipeline, including testing & Commissioning etc. complete as required. |
| 1176 | 100 mm dia |
| 1177 | 50 mm dia |
| 1178 | Supplying, Installation, Testing and Commissioning of underwater Luminaries surface mounted RGB LED spot light 6 x 3W with IP 68 protection, SS/ aluminum dia casting body with power coated paint, soft rubber gasket along with 2 years free replacement guaranty etc. complete as required.. |
| 1179 | Supplying, Installation, Testing and Commissioning of underwater Luminaries surface mounted RGB LED spot light 3 x 3W with IP 68 protection, SS/ aluminum dia casting body with power coated paint, soft rubber gasket along with 2 years free replacement guaranty etc. complete as required. |
| 1180 | Supplying, Installation, Testing and Commissioning of water proof (IP 68) power supply unit of not less than 200W i/c connection along with 2 years free replacement guaranty etc. complete as required. |
| 1181 | Supplying, Installation, Testing and Commissioning of RGB controller with remote Kit wattage not less than 200 watt i/c connection along with 2 years free replacement guaranty etc. complete as required. |
| 1182 | Supplying, Installation, Testing and Commissioning of Signal Amplifier of RGB signal as require i/c connection along with 2 years free replacement guaranty etc. complete as required. |
| 1183 | Supplying, Installation, Testing and Commissioning of fixing of Power Supply/SMPS for suitable to run LED Lights, Body-Metal input Power-220 V AC/ Output Power-12 V DC etc. complete as required. |
| 1184 | Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required. |
| 1185 | 3 Core 1.5 Sq mm Flat Cable |
| 1186 | 3 Core 2.5 Sq mm Flat Cable |
| 1187 | 3 Core 4.0 Sq mm Flat Cable |
| 1188 | 3 Core 6 Sq mm Flat Cable |
| 1189 | 3 Core 10 Sq mm Flat Cable |
| 1190 | HT Cable Laying |
| 1191 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1192 | Upto 120 sq. mm |
| 1193 | Above 120 sq. mm and upto 400 sq. mm |
| 1194 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1195 | Upto 120 sq. mm |
| 1196 | Above 120 sq. mm and upto 400 sq. mm |
| 1197 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 1198 | Upto 120 sq. mm |
| 1199 | Above 120 sq. mm and upto 400 sq. mm |
| 1200 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. |
| 1201 | Upto 120 sq. mm |
| 1202 | Above 120 sq. mm and upto 400 sq. mm |
| 1203 | Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1204 | Upto 120 sq. mm |
| 1205 | Above 120 sq. mm and upto 400 sq. mm |
| 1206 | Laying of one number additional XLPE power cable of 33 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1207 | Upto 120 sq. mm |
| 1208 | Above 120 sq. mm and upto 400 sq. mm |
| 1209 | Laying of one number XLPE power cable of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 1210 | Upto 120 sq. mm |
| 1211 | Above 120 sq. mm and upto 400 sq. mm |
| 1212 | Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required. |
| 1213 | Upto 120 sq. mm |
| 1214 | Above 120 sq. mm and upto 400 sq. mm |
| 1215 | HV Cable Jointing & End Termination |
| 1216 | Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 1217 | 70 sq. mm |
| 1218 | 120 sq. mm |
| 1219 | 240 sq. mm |
| 1220 | 300 sq. mm |
| 1221 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 1222 | 70 sq. mm |
| 1223 | 120 sq. mm |
| 1224 | 240 sq. mm |
| 1225 | 300 sq. mm |
| 1226 | Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required |
| 1227 | 70 sq. mm |
| 1228 | 120 sq. mm |
| 1229 | 240 sq. mm |
| 1230 | 300 sq. mm |
| 1231 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: |
| 1232 | 70 sq. mm |
| 1233 | 120 sq. mm |
| 1234 | 240 sq. mm |
| 1235 | 300 sq. mm |
| 1236 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 1237 | 70 sq. mm |
| 1238 | 120 sq. mm |
| 1239 | 240 sq. mm |
| 1240 | 300 sq. mm |
| 1241 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 1242 | 70 sq. mm |
| 1243 | 120 sq. mm |
| 1244 | 240 sq. mm |
| 1245 | 300 sq. mm |
| 1246 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : |
| 1247 | 70 sq. mm |
| 1248 | 120 sq. mm |
| 1249 | 240 sq. mm |
| 1250 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : |
| 1251 | 70 sq. mm |
| 1252 | 120 sq. mm |
| 1253 | 240 sq. mm |
| 1254 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : |
| 1255 | 70 sq. mm |
| 1256 | 120 sq. mm |
| 1257 | 240 sq. mm |
| 1258 | UNINTERRUPTED POWER SUPPLY |
| 1259 | Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc |
| 1260 | 10KVA |
| 1261 | Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc |
| 1262 | 10KVA (Each Power module shall be < 10 KVA) |
| 1263 | 20KVA (Each Power module shall be < 10 KVA) |
| 1264 | 30KVA (Each Power module shall be < 10 KVA) |
| 1265 | 40KVA (Each Power module shall be < 10 KVA) |
| 1266 | 60KVA (Each Power module shall be < 10 KVA) |
| 1267 | 80KVA (Each Power module shall be < 25 KVA) |
| 1268 | 100KVA (Each Power module shall be < 25 KVA) |
| 1269 | 120KVA (Each Power module shall be < 25 KVA) |
| 1270 | 160KVA (Each Power module shall be < 25 KVA) |
| 1271 | 200KVA (Each Power module shall be < 50 KVA) |
| 1272 | 300KVA (Each Power module shall be < 50 KVA) |
| 1273 | 400KVA (Each Power module shall be < 50 KVA) |
| 1274 | 500KVA (Each Power module shall be < 50 KVA) |
| 1275 | EPABX /IPABX |
| 1276 | Supplying, installation, testing and Commissioning of IP based voice communication system with 04 Port Voicemail, 04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP Facility, min 100 IP users License with provision for further additions, 100 analog users, 01 Number IP based Operator Console, 100 Party Conference, Speed Dial, Music on Hold, Internal/ External ring difference, Call Barring, Call Pickup, Redundant server in active -Active mode and as per technical specification including supporting accessories etc complete as required. The system should have valid TEC GR approval from DoT. |
| 1277 | Supplyiing, installation, testing and Commissioning of IP at its core with IP switching technology and 100% non blocking communication system with 04 Port Voicemail, 04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP Facility, min 100 IP users License with provision for further additions, 100 analog users, 01 Number IP based Operator Console, 45 Party Conference, Speed Dial, Music on Hold, Internal/ External ring difference, Call Barring , Call Pickup. The system should be redundant which offer 100% duplication of power supply and CPU card and to match the hybrid IP-PBX as per technical specification including supporting accessories etc complete as required. The system should have valid TEC GR approval from DoT. |
| 1278 | Supplying, Installation, Testing & Commissioning of Type 1 IP Phone having 2 VoIP account, 120 x40 DOT matrix screen with backlight, Full HD duplex speaker phone, IPV6, Gigabit Etherent, PoE etc. complete as required. |
| 1279 | Supplying, Installation, Testing & Commissioning of Analog phones having standard feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc. complete as required. |
| 1280 | Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC Conduit etc. complete as required. |
| 1281 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of - 5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1282 | 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 1283 | 8 port Layer 2 Non-PoE Network Switch |
| 1284 | Supplying, installation, Testing and commissioning of following capacity 8 port PoE Layer 2 Industrial Grade outdoor Network Switch having features and specifications etc. as mentioned here under: At least 8 X RJ-45 PoE/PoE+ Gigabit Ethernet Ports and additional 4 X 1G SFP Ports with non-blocking architecture by having Switching capacity of min.24Gbps and packet forwarding rate of 17Mpps or higher, console port, 16K MAC table, IPv4 and IPv6 ready, IGMP snooping v1, v2, v3, DHCP,DHCP Relay, NTP/SNTP, SNMPv1, v2 C v3, TELNET/ SSH, LACP, STP, RSTP, MSTP, ERPS. VLAN: Port based, Mac based , IP subnet based, tag based, protocol based. Ǫ - in Ǫ, L2/L3 ACL, 1588v2 Precision Time Protocol HW - Based E2E Transparent clock, SNTP, TFTP, SNMP, Radius, Syslog. Dual DC Power input, IP30 rated, DIN Rail, -5° to 70° C operating temperature. Certificate: UL, CE, FCC, NEMA-TS2, IEC/MIL-STD for Shock , Vibration & Drop Certificate. OEM Should have Certificate for Industrial Cyber Security Capability IEC- 62443-4-1:2018, ISO 45001, ISO 27001 and ISO 14001 Certified or Equivelent Indian Certificate. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1285 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ -in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS + Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1286 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 1287 | 24 port Layer 2 Non-PoE Network Switch |
| 1288 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Network Switch having features and specifications etc. as mentioned here under: At least 20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo 10/100/1000 base-t/SFP Ports with additional 4 SFP+ ports non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Internal AC Power supply with operating temperature of 0 to +50 0C. Stacking port with stacking support of minimum 8 units per stack. 48K Mac address, 9K or more Jumbo frame, ERPS with enabling ring to converge in less than 50 ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE, IPv6 Neighbor Discovery (ND), BGP, ISIS, MPLS, VRRP v2, OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1 for both IPv6 and IPv4, 802.1x, Port security , Radius C TACACS+ authentication C accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access List, MAC Access List. Multicast: VLAN, PIM-SM, PIM- DM, PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP, IGMP C MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per -VLAN IGMP C MLD Snooping. SNMP, Dual configurations, Multiple images, RMON, LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client, IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link OAM, 802.1ag Connectivity Fault, Y.1731 OAM, 802.1Ǫbb Priority - based Flow Control (PFC), Dying Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1289 | Supplying, installation, Testing and commissioning of 10 Giga Bandwidth Data Centre Network Switch of 48 port Layer 3 having features and specifications etc. as mentioned here under: - ToR/EOR/Core Network Switch 48x 10GbE SFP+, 6x 100GbE QSFP28, RPS, with Console Port, Management Port and 1 x USB 2.0 Type A port, The switch must provide a switching capacity of no less than 2.16 Tbps and a forwarding rate of at least 1600 Mpps, ensuring non-blocking performance for high-bandwidth applications. It should support hot-swappable dual power supply modules (AC or DC) for 1+1 redundancy and load sharing, as well as hot-swappable, front- to-back airflow fan trays with N+1 redundancy to ensure continuous availability. IEEE 802.1X support for port-based and MAC-based authentication should be available, along with integration for RADIUS and TACACS+ authentication services. Guest VLANs, DoS prevention, and management access restrictions are essential. SNMP v1/v2c/v3, syslog, sFlow, and support for auto- configuration via DHCP. Support for OpenFlow v1.4, Netconf/YANG, and LLDP is required for modern network automation. Support ONIE (Open Network Install Environment), IEEE 802.1Q bb Priority-based Flow Control (PFC), OpenFlow v1.4, ERPS, IPv6 Tunneling, IP interfaces and supported, VXLAN, Private VLAN, Multicast VLAN, Guest VLAN Double VLAN (Q- in-Q), RoCEv2, PIM-SSM/SM, MSDP. Support High Availability with MLAG/VSS and Layer 2/3 VPNs Critical for Multi-tenant, Virtualized, and Containerized Environments. BGPv4/v6, OSPFv2/v3, IS-IS, RIPng. VRRP, ECMP, BFD, and route redistribution for high-availability routing. Support flexible routing domains and secure inter-segment traffic flow. Certifications: CE, FCC, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1290 | Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. |
| 1291 | 39.6.1 1G SFP Single Mode/Multi Mode |
| 1292 | 39.6.2 1G Copper SFP |
| 1293 | 39.6.3 10 G SFP + Single Mode/Multi Mode |
| 1294 | 39.6.4 40G SFP |
| 1295 | 39.6.5 100G SFP |
| 1296 | Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for Low Density use having features and specifications etc. as mentioned here under - Dual-band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6 Certified, 1 x RJ45 console port, 1G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks , Certifications: MTCTE, CE, FCC. Should also work as Standalone and must be Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1297 | Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client ., Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Bas ed Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1298 | Supplying, Installation, Testing and commissioning of Outdoor Wireless Access Point having features and specifications etc. as mentioned here under - WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, 4 x internal antennas, the transmission coverage of shall be minimum 80 meters in radius, AP should have transmission power minimum of 22 dBm, The AP shall provide a minimum of 29 dBm EIRP for both 2.4 GHz and 5 GHz frequencies. Feild deployment shall be with EIRP as per regulatory guidelines, AP shall have dual-band Omni-directional Antenna, either internal or external. Feild deployment shall be with EIRP as per the WPC guideline, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA- PSK/WPA2-PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, IP68 water/dustproof standard, 6KV Surge Protection; 4KV ESD Protection (contact), 6KV (air), Operating ambient temperature (-5~50 °C), Grounding point support, IEC 60601-1-2 EMC Medical Electrical Equipment Testing and Certification, EN50121-1 & EN50121-4 for Wireless Application. Certifications: MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role- Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. |
| 1299 | Supplying, Installation, Testing and commissioning of indoor Wireless Controller having features and specifications etc. as mentioned here under- The network controller shall be a dedicated hardware appliance designed for centralized management of wireless access points, It must support the management of up to 500 networking devices, The system should be on-premise, ensuring data privacy and complete control over network configurations. It must include an intuitive user interface for real-time monitoring, device discovery, firmware upgrades, scheduling, and mass configuration deployment. Features such as role-based administration, multi-site management. AP to controller communication shall be use of industry standards-based (IEEE or IETF) CAPWAP or any tunneling protocols as per guidelines of DoT.The controller should support Layer 2 and Layer 3 device discovery, VLAN configuration, MAC ACL groups, IGMP snooping, and bandwidth optimization. Automatic radio frequency (RF) management and access policy enforcement are required for reliable wireless performance. The solution must offer a comprehensive dashboard with network topology, floor plan views, client and device lists, and alert notifications. For authentication, it should support a range of methods including local database, external RADIUS, LDAP, and passcode or MAC-based access. It should provide detailed traffic analytics, logs, and customizable reporting for network visibility and planning. Firmware and configuration backup and restoration functions must be available, with USB- based log storage supported. Physical specifications should include a compact form factor with a minimum of one 2.5G Ethernet port and USB 3.0 port, and it must be MTCTE,CE, FCC, and RoHS certified. The controller should operate reliably within a 0°C to 40°C temperature range and 10–90% non-condensing humidity. /Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1300 | Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 1301 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 1302 | Copper Patch Cords of length 1m (3ft) |
| 1303 | Copper Patch Cords of length 3m (10ft) |
| 1304 | Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 1305 | Copper Patch Cords of length 1m (3ft) |
| 1306 | Copper Patch Cords of length 3m (10ft) |
| 1307 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 1308 | Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 1309 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 1310 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 1311 | 1 Run of cable |
| 1312 | 2 Run of cable |
| 1313 | 3 Run of cab le |
| 1314 | 4 Run of cable |
| 1315 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. |
| 1316 | 1 Run of cable |
| 1317 | 2 Run of cable |
| 1318 | 3 Run of cable |
| 1319 | 4 Run of cable |
| 1320 | Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR- 20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cut- off wavelength < 1260 nm i/c splicing & marking etc complete as required. |
| 1321 | Single Mode 6 Core Optical fiber cable |
| 1322 | Single Mode 12 Core Optical fiber cable |
| 1323 | Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 µm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA- 568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793- 1/60794-1- 2, ITU-T-REC G.652D and Telecordia GR- 20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 d B/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 µm and 125 ± 1µm correspondingly i/c splicing & marking etc complete as required. |
| 1324 | 6 Core Multi Mode Optical Fiber Cable |
| 1325 | 12 Core Multi Mode Optical Fiber Cable |
| 1326 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built- in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. |
| 1327 | 6 Port LIU |
| 1328 | 12Port LIU |
| 1329 | 24 Port LIU |
| 1330 | Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm, Fiber Height + 100 nm, E nd-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required. |
| 1331 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 1332 | 6U Rack |
| 1333 | 9U Rack |
| 1334 | 15U Rack |
| 1335 | Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 1336 | Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 1337 | Supplying and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required. |
| 1338 | CCTV Camera System |
| 1339 | Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DN R (3D) O n/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30 fps,Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE (802.3af) —to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22)Standards: BIS with ER, STQC Certified, CE, FC C and RoHS |
| 1340 | 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens |
| 1341 | 2MP @ 25/30fps@1080P (1920×1080) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. |
| 1342 | Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7 23 4) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DN R (3D) O n/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable(Main stream: 2MP (1920 × 1080)@25/30 fps Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE (802.3af) —to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 1343 | 2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens |
| 1344 | 2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. |
| 1345 | Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On /Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE (802.3af) —to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS. |
| 1346 | 4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement) |
| 1347 | 4MP @ 25/30fps@1440P (2560x1440) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. |
| 1348 | Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4)Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) O n/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detectio8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE (802.3af) —to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 1349 | 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) |
| 1350 | 4MP @ 25/30fps@1440P (2560x1440) Outdoor Bullet Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. |
| 1351 | Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :- 1)Type of Camera: Dome Camera 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night. 9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Water Marking 17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device,) Edge Analytics : Tripwire, Intrusion, Motion Detection 20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port 22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) System Capability: ONVIF 25) VMS: Camera shall support open source VMS 26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 27) Ethernet: 1 RJ 45 10/100 Ethernet port 28) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE —to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 30) Enclosure: IP67 weather proof, IK10 31) Operating Condition: Ambient Temperature:- (- ) 05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 1352 | 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera. |
| 1353 | 5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens Dome Camera. |
| 1354 | Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc :- 1) Type of Camera: Bullet Camera 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Lens Type & Focus: as given below. 9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 Mtrs for colour view in night. 10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 11)Wide Dynamic Range: WDR (120dB or more) 12) Digital Noise Reduction: DNR (2D/3D) On/Off 13) Streaming: Triple streaming, configurable 14) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5MP/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 16) Profile Management: User configuration import, export 17) Security: User Authentication, Digital Water Marking 18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 19) Recording Management: Format SD, overwrite, storage management, video to NAS device, Edge Analytics: Tripwire, Intrusion, Motion Detection 21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 22) Alarm Support: It should have 1/1 Alarm In/ Out Port 23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/ AAC/ G.726 audio compreesion 24) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 25) System Capability: ONVIF 26) VMS: Camera shall support open source VMS 27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, , video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 28) Ethernet: 1 RJ 45 10/100 Ethernet port 29) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE —to ensure continuous operation in the event of a failure in one power source. 30) Power Requirement: 12VDC/24V DC/PoE (802.3af)/ePoE 31) Enclosure: IP67 weather proof, IK10 32) Operating Condition: Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 33) IR life: 40000 hours or higher 34) Video Bit rate: 32 KBPS - 8 MBPS or better 35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 1355 | 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) outdoor bullet Camera |
| 1356 | 5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera. |
| 1357 | Supplying Installation Testing and Commissioning of 8 MP IP IR Dome Camera having following specifications and features etc :-1) Type of Camera: Dome Camera 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 meter for colour view in night. 9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP @25/30 fps & D1@25/30 fps; 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Water Marking 17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device, 19) Edge Analytics: Tripwire, Intrusion, Motion Detection 20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection Alarm Support: It should have 1/1 Alarm In/ Out Port 22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) System Capability: ONVIF 25) VMS: Camera shall support open source VMS 26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 27) Ethernet: 1 RJ 45 10/100 Ethernet port 28) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE —to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 30) Enclosure: IP67 weather proof, IK10 31) Operating Condition: Ambient Temperature:- (- ) 05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 1358 | 8 MP (3840 × 2160) or better IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera, |
| 1359 | 8 MP (3840 × 2160) or better IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens Dome Camera. |
| 1360 | 8 MP IP IR Outdoor Bullet Camera Supplying Installation Testing and Commissioning of 8 MP IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Type of Camera: Outdoor Bullet Camera 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt Smart IR LED's with effective distance upto 50 Mtrs integrated IR and 30 meter for colour view in night 9) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10)Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13)Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP @25/30 fps & D1@25/30 fps; 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Digital Water Marking 17) Onboard Storage; Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device, 19) Edge Analytics: Tripwire, Intrusion, Motion Detection 20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) User Access: Minimum 08 Users 25) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation). 26) VMS: Camera shall support open source VMS 27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 28) Ethernet: 1 RJ 45 10/100 Ethernet port 29) Power Input: The camera should support simultaneous dual power input —12 VDC (via power adapter) and PoE —to ensure continuous operation in the event of a failure in one power source. 30) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 31) Enclosure: IP67 weather proof, IK10 32) Operating Condition: Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 33) IR life: 40000 hours or higher 34) Video Bit rate: 32 KBPS - 8 MBPS or better 35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 1361 | 8 MP (3840 × 2160) or better IP IR 2.8/ 3.6/6/8/12 mm fixed lens |
| 1362 | 8 MP (3840 × 2160) or better IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera. |
| 1363 | Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- 1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS 3)Signal System: PAL/NTSC 4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,, 0 lux with IR, or better 5) Imaging: 1/1s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Event Notification: Through Relays, E-Mails or FTP 9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance. The camera should have IR LED’s and cover distance up to 300 meter or above 10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it. 11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering. 12) Presets: 300 Presets 13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 14) Wide Dynamic Range: WDR (120dB or more), HLC & BLC 15) Digital Noise Reduction: DNR (2D+3D) On/Off 16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser 17) Profile Management: User configuration import, export Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution 19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be supplied with minimum 128GB Memory. 20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login 21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, Face Detection 22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS. 23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation). 24) VMS: Camera shall support open source VMS 25) Connectivity: 1x LAN RJ-45 (10/100Base- T) 26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.1 27) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out 28) Power Input: The camera should support simultaneous dual power input —DC/ AC (via power adapter) and PoE (802.3af) —to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at) 30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection 31) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 1364 | 2 MP IP IR motorized PTZ @ 25/30fps or better camera, Triple streaming , configurable on resolution Main stream: 1080p@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.3-137 mm or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digital zoom with angle of view 57˚–2.4˚ , PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt, Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s |
| 1365 | 4 MP IP IR motorized PTZ (4MP @25/30fps or better) camera, Triple streaming , configurable on resolution Main stream: 4MP@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.5-135mm or better with Automatic & manual Focus Adjustment provisions, 30x Optical zoom and 12x Digital zoom with angle of viewH : 57˚–2.4˚, m, PAN Travel: Pan: 0° ~ 360° endless;Manual Pan: 300° /s, Preset : 300° /s, Tilt Travel: Tilt: 0-90°, auto flip 180°, Manual Tilt: 200° /s, Preset : 300° /s |
| 1366 | 5MP IP IR motorized PTZ @25/30fps or better camera, Triple streaming , configurable on resolution:- Main stream: 5MP@25/30 fps Sub streams:1080p@25/30 fps, varifocal lens 3.95mm (±5mm) ~ 177.75mm (±5mm) or better with Automatic & manual Focus Adjustment provisions, 45x Optical zoom and 16x Digital zoom with angle of view H: 65.7° –1.9°V: 39.4° –1.1°D: 73.1° –2.1, PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s |
| 1367 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support 3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot. 6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232 7) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0) 8) Video Output Ports: 1x HDMI and 1 VGA 9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS and BIS Certified 14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply. 15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensin g) 16) The VMS, NVR application shall support all the features & functionalities of the offered cameras. 17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×768 21) Must support recording resolution upto 32MP 22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file. 26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan 28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detectio n speed of 12 face images/sec. 31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytic |
| 1368 | 08 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9, 2nd screen: 1/4/8/9 |
| 1369 | 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 1370 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H.265 or better, H.264, MJPEG. 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0) 8) Video Output Ports: 2x HDMI and 2 VGA 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6 , UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21)It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF 22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 34) Analytics by NVR: Perimeter protection and face recognation |
| 1371 | 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 1372 | 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 |
| 1373 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 1374 | 4TB (Terabytes) |
| 1375 | 6TB (Terabytes) |
| 1376 | 8TB (Terabytes) |
| 1377 | 10TB (Terabytes) |
| 1378 | Access Control System |
| 1379 | Access Control System with Face recognition Supplying, Installation, Testing and Commissioning of Access Control System comprising of Face and fingerprint Recognition, Smart Card, QR Code, NFC & PIN Code based Reader, following sizes of 5” IPS TFT Touch Screens, 1GB RAM, 8 GB ROM, Live Face Detection with anti-spoofing against 2D photograph, mobile selfie & video, Fake Fingerprint and face Detection Technology, 30,000 Face storage (1:N) /, 3,000 fingerprint (1:N), QR code 30,000, 30,000 card storage (1:N), 2 lakh transaction storage, 20,000 image logs, onboard dual camera (colour & IR) Primary camera min 2MP, Support Face authentication & verification from up to 1 meters, Communication protocols WiFi, TCP/IP, Wiegand Out, Wiegand IN, USB, MQTT protocol, Blacklist Employee Management, User wise authentication modes; Built in Lock Control, Mask Detection & Alert (configurable), 40 to 30,000 lux illumination, IP65 for Ingress Protection, Certification: CE, FCC, BIS, ROHS, etc. Metal Enclosure with battery backup, suitable for mounting on metal surface/metal frames/ wooden frames/wall/flap barriers including all mounting bracket & accessories complete etc. as required. 5\\" IPS TFT Touch Screen |
| 1380 | Access Control System (without Finger Print) Supplying, Installation, Testing and Commissioning of Access Control System comprising of Face Recognition, Smart Card, QR Code, NFC & PIN Code based Reader, following sizes of 5” IPS TFT Touch Screens, 1GB RAM, 8 GB ROM, AES 128 bit encrypted, Live Face Detection with anti-spoofing against 2D photograph, mobile selfie & video, Fake Fingerprint Detection Technology, 10,000 Face storage (1:N) /, 10,000 card storage (1:N), QR code storage 10,000 (1:N), 2 lakh transaction storage, 20,000 image logs, onboard dual camera (colour & IR) Primary camera min 2MP, Support Face authentication & verification from up to 1 meters, Communication protocols WiFi, TCP/IP, Wiegand Out, USB, MQTT protocol, Blacklist Employee Management, User wise authentication modes; Built in Lock Control, Mask Detection & Alert (configurable), 40 to 30,000 lux illumination, IP54 for Ingress Protection, Certification: CE, FCC, BIS, ROHS, WPC etc. Metal enclosure with battery backup, suitable for mounting on metal surface/metal frames/ wooden frames/wall/flap barriers including all mounting bracket & accessories complete etc. as required. |
| 1381 | Access Control System with 2.8\\" display (without Face Recognition Readers) Supplying, Installation, Testing and Commissioning of Access control system comprising of fingerprint, card, and password authentication and having following specifications: · Auth entication Methods: Fingerprint, Card & Password with Capacitive Touch screen. · Fin gerprint Detection: Fake Fingerprint Detection Technology. · Displa y: 2.8\\" TFT touch Screen display. · Ca pacity: 10,000 Fingerprint storage (1:N). · Lo gs: 200,000 transaction logs. · Pow er: 12V DC. (UL listed) · Co mmunication Protocols: TCP/IP, WiFi, USB, Wiegand Out / IN, RS 485. · Add itional Features: User-wise authentication modes, Built-in Lock Control. · Ce rtifications: CE, FCC, RoHS, BIS. · Env ironmental: IP 54 Ingress Protection. · Mo unting: Suitable for metal surfaces/frames, wooden frames, walls, and flap barriers. |
| 1382 | Access Control System with 1.77\\" display (without Face Recognition Readers) Supplying, Installation, Testing and Commissioning of Access Control System comprising of Fingerprint & Card based Reader with 1.77\\" LCD Display, Fake Fingerprint Detection Technology, supports ANSI 378 encryption, AES 128 bit encrypted algorithm to protect important info such as personal info transmitted, 5,000 Fingerprint storage (1 :N) / 10,000 Fingerprint storage (1 :1), 50,000 transaction logs, Onboard Camera to capture live images against transactions, Communication protocols like TCP/IP, Wiegand Out / IN, RS 485, OSDP; Supports Mobile Key through Bluetooth, User wise authentication modes; Built in Lock Control; UL Listed Power Supply, Certification: CE, FCC, RoHS, BIS, WPC, Ingress Protection IP 65 etc. suitable for mounting on metal surface/metal frames/ wooden frames / wall / flap barriers including all mounting bracket & accessories complete etc. as required. |
| 1383 | Software for Web based Access Control System Supplying, Installation, Testing and Commissioning of Web based Access Control Enrolment and Device Configuration Software, Should be independent of OS (Windows), Unified Management of Biometric, Card, and Controllers, Import Functionality for bulk user details, Biometric Template Retrieval for Data Recovery, User Management, Logs and Terminal Management, Support for IP-based and USB Biometric Devices, User-specific Access Policies, Different User Policies on the Same Terminal, Assignment of Specific Access Schedules, Pushing Users to Terminals or Groups, Admin Authority Management to define rights of each user to perform, Blacklist User Management, Access Schedule Creation, Real-Time Log Retrieval, Real- Time User Identification, Secure Storage of Biometric/Users Data, Capable to integrate with 3rd party applications over Web API's, MQTT protocol support |
| 1384 | Electromagnetic locks Supplying, Installation, Testing and Commissioning of Electromagnetic locks (fail safe type) for following type of Doors suitable for operation on 12 V DC having holding force 600 lbs for Single Leaf Door and 1200lbs for Double leaf door with suitable feedback i/c connection complete etc. as required. |
| 1385 | Single leaf door |
| 1386 | Double leaf door (Each leaf 600lbs & Total 1200 lbs) |
| 1387 | Exit Push Button Supplying, Installation, Testing and Commissioning of Heavy Duty SS Finish Exit Push Button for releasing access doors with all necessary installation accessories i/c connection complete etc. as required. |
| 1388 | Door Position Sensor Supplying, Installation Insta, Testing and Commissioning of Door Position Sensor i/e connection complete etc. as required. |
| 1389 | BASIC LABOUR RATES |
| 1390 | Wireman day |
| 1391 | Cable jointer |
| 1392 | Lineman |
| 1393 | Fitter, Grade 1 |
| 1394 | Fitter, Grade 2 |
| 1395 | Khallasi day |
| 1396 | Highly Skilled Worker day |
| 1397 | Electrician day |
| 1398 | Electronic Technician |
| 1399 | Suply installiation testing and commissioning of T5 tubes 28 w or as per site requirement or already installed |
| 1400 | Repairing of wall and ceiling fans by way of rewinding ,replacing damaged capacitors etc |
| 1401 | cleaning of wall and ceiling fans |
| 1402 | Suply installiation testing and commissioning of 20 W bulk head lights |
| 1403 | Suply installiation testing and commissioning of T5 tubes 14 w or as per site requirement or already installed |
| 1404 | Supply, installation, testing and commissioning of 12V, 100Ah Sealed Lead Acid Battery |
| 1405 | Supply, installation, testing and commissioning of 12V, 150Ah Sealed Lead Acid Battery |
| 1406 | Supply, installation, testing and commissioning of 12V, 180Ah Sealed Lead Acid Battery |
| 1407 | Supply, installation, testing and commissioning of 12V, 200Ah Sealed Lead Acid Battery |
| 1408 | Supply, installation, testing and commissioning of 12V, 220Ah Sealed Lead Acid Battery |
| 1409 | Supply, installation, testing and commissioning of 12V, 35Ah maintenance free Battery |
| 1410 | Supply, installation, testing and commissioning of 12V, 42Ah maintenance free Battery |
| 1411 | Supply, installation, testing and commissioning of 12V, 50Ah maintenance free Battery |
| 1412 | Supplyof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size/core. |
| 1413 | Single Core LT Cable (Un-Armoured) |
| 1414 | 35 sq. mm |
| 1415 | 50 sq. mm |
| 1416 | 70 sq. mm |
| 1417 | 95 sq. mm |
| 1418 | 120 sq. mm |
| 1419 | 150 sq. mm |
| 1420 | 185 sq. mm |
| 1421 | 240 sq. mm |
| 1422 | 300 sq. mm |
| 1423 | 400 sq. mm |
| 1424 | 500 sq. mm |
| 1425 | 630 sq. mm |
| 1426 | 800 sq. mm |
| 1427 | 1000 sq. mm |
| 1428 | Single Core LT Cable (Armoured) |
| 1429 | 35 sq. mm |
| 1430 | 50 sq. mm |
| 1431 | 70 sq. mm |
| 1432 | 95 sq. mm |
| 1433 | 120 sq. mm |
| 1434 | 150 sq. mm |
| 1435 | 185 sq. mm |
| 1436 | 240 sq. mm |
| 1437 | 300 sq. mm |
| 1438 | 400 sq. mm |
| 1439 | 500 sq. mm |
| 1440 | 630 sq. mm |
| 1441 | 800 sq. mm |
| 1442 | 1000 sq. mm |
| 1443 | 3½ Core LT Cable (un-Armoured) |
| 1444 | 35 sq. mm |
| 1445 | 50 sq. mm |
| 1446 | 70 sq. mm |
| 1447 | 95 sq. mm |
| 1448 | 120 sq. mm |
| 1449 | 150 sq. mm |
| 1450 | 185 sq. mm |
| 1451 | 240 sq. mm |
| 1452 | 300 sq. mm |
| 1453 | 400 sq. mm |
| 1454 | 500 sq. mm |
| 1455 | 630 sq. mm |
| 1456 | 3½ Core LT Cable (Armoured) |
| 1457 | 35 sq. mm |
| 1458 | 50 sq. mm |
| 1459 | 70 sq. mm |
| 1460 | 95 sq. mm |
| 1461 | 120 sq. mm |
| 1462 | 150 sq. mm |
| 1463 | 185 sq. mm |
| 1464 | 240 sq. mm |
| 1465 | 300 sq. mm |
| 1466 | 400 sq. mm |
| 1467 | 500 sq. mm |
| 1468 | 630 sq. mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail