| 1 | Supply and installation of following sizes of Heavy Duty, Hot Dip Galvanised GI pipes with required accessories on Floor, column, beams etc including chasing and replastering as per the detailed specification.(Refer Sec VI, Clause No.28). |
| 2 | 415V Class - IV, Power Distribution Panel HALL-1 as per dwg no.IGC/T-1761/01 |
| 3 | 415V Class - IV, Main Power Distribution Panel ZWS as per dwg no.IGC/T-1761/02 |
| 4 | 415V Class - IV, Power Distribution Panel ZWS AUX.I as per dwg no.IGC/T-1761/03 |
| 5 | 415V Class - IV, Power Distribution Panel ZWS AUX.II as per dwg no.IGC/T-1761/04 |
| 6 | Supply, open installation, testing and commissioning of the following sizes of VTPN DBs with MCCB & MCB on MS frame work (MS frame will be measured separately) as per the scope of work. (Refer Sec VI, Clause No.15.1). |
| 7 | DB VTPN 8 Way (8 Plus 24) IP 43 - IK 09 with 1No. 125A, 4 Pole DPX3 MCCB (for Incomer) and 8 Nos. 32A,3P MCB (for outgoing), Cat No:507747 or equivalent. The scope includes suply of 1 No. spare MCCB of same make and rating as per section V Part A Clause No.13) |
| 8 | DB VTPN 8 Way (8 Plus 24) IP 43 - IK 09 with 1No. 160A, 4 Pole DPX3 MCCB (for Incomer) and 8 Nos. 63A,3P MCB (for outgoing), Cat No:507747 or equivalent. The scope includes suply of 1 No. spare MCCB of same make and rating as per section V Part A Clause No.13) |
| 9 | VTPN,8 way Cable end box, Cat No: 5079 38 or equivalent suitable for VTPN DB, 8 way with MCCB incomer Distribution Board Cat No:5077 47(Refer Section V ,Clause No.14 ) |
| 10 | Supply, open installation, testing and commissioning of following POWDER COATED TPN/SPN DB Enclosures with Double Door and per Phase isolation DBs consisting of Phase, Neutral and Earth Bus and interconnecting wires etc on MS frame work (MS frame will be measured separately) , as per the detailed specification and as directed by the Engineer-in-charge.(Refer Sec VI, Clause No.15.2). |
| 11 | 12 WAY Cat No:DETPI012DD (Vertical) or equivalent make TPN TIER Per Phase Isolation (PPI) DB |
| 12 | 8 WAY Cat No:DETPI008DD (Vertical) or equivalent make TPN TIER Per Phase Isolation (PPI) DB |
| 13 | Supply, open installation, testing and commissioning of following sizes Cable end termination boxon MS frame work (MS frame will be measured separately) as per the detailed specification and as directed by the Engineer-in-charge.(Refer Sec VI, Clause No.15.2.2). |
| 14 | TPN,12 way Cable end box, Cat No:DBTPI012CB or equivalent suitable for TPN, 12 way TPN TIER Per Phase Isolation Distribution Board Cat No:DBTPI012DD (Vertical) |
| 15 | TPN,8 way Cable end box, Cat No:DBTPI008CB or equivalent suitable for TPN, 8 way TPN TIER Per Phase Isolation Distribution Board Cat No:DBTPI008DD |
| 16 | Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). |
| 17 | 6-32 Amps SP MCB (Type-C) |
| 18 | 40-63Amps, FP MCB (TYPE-C) |
| 19 | Supply fixing testing and commissioning of the following RCBOs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). |
| 20 | RCBO DP 25A sensitivity 30mA TYPE AC, 2Module |
| 21 | RCBO DP 32A sensitivity 30mA TYPE AC, 2Module |
| 22 | Assembling, installation, testing and commissioning of MCB DB enclosure already installed on the wall including supply of Engraved Circuit Identification Plate and Danger Board as per the detailed specification for the following size of MCB DBs. (Refer Sec VI, Clause No.15.3). |
| 23 | TPN, 12 Way Distribution Board |
| 24 | TPN, 8 Way Distribution Board |
| 25 | Wiring for lights / fans /sensors/ Timer /Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, switches/ sockets, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18) |
| 26 | Wiring for Light/Sensor/Fan Points with 2 Runs of 1.5 Sq.mm copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for Earth from MCB Distribution Board to Primary light/sensor/fan point through Control Switch Box including 6Amps modular switch. |
| 27 | Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch box to Light point/Ceiling fan including 1 No 6A modular switch |
| 28 | Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Light point to Light point /sensor/contactor |
| 29 | Wiring for Fan point with 2 Runs of 1.5 Sq.mm copper wire for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for Earth from MCB Distribution Board/Switch Box to Fan point through Control Switch Box including 6A modular switch and step type Fan regulator |
| 30 | Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including 16A modular switch, 6/16 Amps combined shuttered type Socket and 6A modular switch & 3 pin, 6A shuttered type Socket, Modular Plate. |
| 31 | Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from Control Switch Box to control switch box including 6A modular switch & 3 pin 6A, shuttered type Socket and 16A modular switch & 3 pin 6/16A combined shuttered type Socket, Modular plate |
| 32 | Wiring for Power Points with 2 Runs of 4.0 Sq.mm Copper wires for Phase, Neutral and 1 Run of 2.5 Sq.mm Copper wires for Earth from MCB Distribution Board to Single Phase Metal Clad Socket. |
| 33 | Wiring for Exhaust fan point up to 3Mtr height with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from MCB Distribution Board to Power point through Control Switch Box including supply of 3 pin 6A shuttered type Socket, 2Nos. 2 Modular plate and 1 No 6A modular switch. |
| 34 | Wiring for Light point with 3 Runs of 2.5 Sq.mm Copper wires for Phase, Neutral and Earth from Distribution Board to Light point through MCB Switch Box including supply of one No. of 6A, Double Pole MCB (At 6 meter height) |
| 35 | Wiring for Light point with 3 Runs of 2.5 Sq.mm Copper wires for Phase, Neutral and Earth from Light point to Light point (At 6 meter height) |
| 36 | Wiring with 1 Run of 1.5 Sq.mm Copper wire |
| 37 | Wiring with 1 Run of 2.5 Sq.mm Copper wire |
| 38 | Supply and installation of 2 Module Double Pole Surface mounting Metal Enclosure box for fixing the double pole MCB,Cat No: 5077 91 or equivalent, (Refer Sec V Part A , Clause No.15) |
| 39 | Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7). |
| 40 | One/Two module |
| 41 | 3 Module |
| 42 | 4 Module |
| 43 | 6 Module |
| 44 | 1 Modular dummy plate |
| 45 | Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29) |
| 46 | 25 X 12 mm size of PVC Mini trunking |
| 47 | 32 X 12mm size of PVC Mini trunking |
| 48 | Supply and external installation of following sizes of Heavy Duty, Hot Dip Galvanised MS ERW Conduits for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc. as per the detailed specification. .(Refer Sec VI, Clause No.27). |
| 49 | 25mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes. |
| 50 | 32mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes. |
| 51 | 40mm dia 2mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes. |
| 52 | Supply and open installation of following Sizes of MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10). |
| 53 | 150(W)X150(H)X80(D)mm, 1.6mm thick sheet MS Box |
| 54 | 300(W)X300(H)X120(D)mm,1.8mm thick sheet MS Box |
| 55 | End Termination of the following size Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). |
| 56 | 4C x 16 Sq.mm including cable gland earthing |
| 57 | Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6). |
| 58 | Surface Mounting Plastic Boxes 6 Module |
| 59 | Surface Mounting Plastic Boxes 4 Module |
| 60 | Surface Mounting Plastic Boxes 3 Module |
| 61 | Surface Mounting Plastic Boxes 1/2 Module |
| 62 | Supply, Installation, Testing and Commissioning of following Flood light luminaries on RCC/Metalic poles of height from 7 M to 12 M as per per the detailed specification. (Refer Sec VI, Clause No.16.1). - Catalogue No : BVP282 LED120 CW FG SY5WB 100W PSU or equivalent and Lamp Type LED |
| 63 | Supply, transportation, installation, testing and Commissioning of the following type of Surface mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : WAND K 30W 5700K code SLWKY03057NDWEP04C22 -SURFACE LIGHTS NONDIM WITH CUSTOMIZED CLAMP OF 30 DEG. TILT WHITE (PC) 4FEET- PRIME or equivalent and Lamp Type LED |
| 64 | Supply, transportation, installation, testing and Commissioning of the following types of Suspended luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : CANE STD LINEAR PENDANT 40W, 5700K-4FT Item code LPC0104057NDWEP0DL4C01 with downrod replacement fixing accessories or Equivalent and Lamp Type LED |
| 65 | Supply, Installation, testing and commissioning of following sizes of ceiling Fans and safety steel rope with 3 Core, 1.5 Sq.mm (14/0.3) flexible copper cable including earth connection. Supply and fixing of regulator is not included in the scope of this item. (Refer Sec VI, Clause No.17.1). |
| 66 | 1200mm Sweep AC ceiling fan |
| 67 | Supply, transportation, installation, testing and commissioning of the following Sensors as directed by the Engineer-in-Charge. (Refer Sec VI, Clause No.16). |
| 68 | PIR based Motion detected sensor suitable for both surface & recess mounting type |
| 69 | Supply, installation, testing and commissioning of following sizes of Wall Mounting Exhaust Fans including supply of Aluminium grill bracket with Stainless Steel Bolts for mounting of Exhaust Fan & Aluminium grill bracket and 3 Core, 1.5 Sq.mm (14/0.3) PVC insulated & FRLS sheathed copper flexible cable of required length as per the detailed specification. (Refer Sec VI, Clause No.17.2). |
| 70 | 300 mm Dia Turbo Heavy Duty Exhaust Fan |
| 71 | Supply, embedment and flush mounting of following sizes of Metal Clad Socket in sheet steel enclosure with Plugs and Socket including chipping and finishing as per the detailed specification.(Refer Sec VI, Clause No.15.4). |
| 72 | 20 AMPS DP Metra Plug and Socket DBs with 20Amps MCB |
| 73 | Supply and installation of the following sizes of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8) |
| 74 | 8SWG copper wire |
| 75 | 14 SWG Copper Wire |
| 76 | Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. No cutting or drilling permitted after galvanisation. (Refer Sec VI, Clause No.12.9). |
| 77 | 25 X 6 mm GI flat |
| 78 | Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats including excavation and refilling as per the detailed specification. No cutting or drilling permitted after galvanisation.Refer Sec VI, Clause No.12.9). |
| 79 | 25 X 6 mm GI flat |
| 80 | Supply and Installation of laminated Hylam sheet of 3mm thickness over the boxes and as per the detailed specification. |
| 81 | Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11 and Sec V, Clause No.16). |
| 82 | MS fabrication 1 coat primer & 2 coats synthetic enamel paint |
| 83 | Supply installation and testing of Maintenance free earthing system TRIPOLAR (3x10feetx5/8inch copper bonded steel rod, 55 kg Ground Enhancing Material (GEM) ) as per IS: 3043 including RCC Chamber and RCC cover as per Drawing No.IGC/ESD/5060/1008/1 enclosed . (Refer Sec VI, Clause No.12.12). |
| 84 | Supply, cleaning the floor, proper pasting and installation of following insulating mat as per specification. (Refer Sec VI, Clause No.25). |
| 85 | 2.0 mm thickness, Max useable voltage 3.3kV, AC Proof voltage 10kV for 3 minutes, AC dielectric strength 30kV RMS Insulating Mat confirming to IS:15652 |
| 86 | Removal, transportation and unloading of 415V industrial type from Hall - I, Hall - II and Zonal Workshop building to storage yard including removal of Power cables connected with the panel. (Refer Sec V Part A, Clause No.17) |
| 87 | End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). |
| 88 | 3.5 x 240 sq.mm |
| 89 | 3.5 x 185 sq.mm |
| 90 | 3.5/4C x 50/70 sq.mm |
| 91 | 3.5/4 C x 35 sq.mm |
| 92 | End Termination of the following size Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). |
| 93 | 4C x 16 Sq.mm including cable gland earthing |
| 94 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) |
| 95 | 3/3.5/4core X Upto 25 sqmm |
| 96 | 3/3.5/4Core X above 120 & up to 240 sqmm |
| 97 | Temporary installation of class IV panel as directed by Engineer-in-charge.(Refer Sec V Part A, Clause No.18) |
| 98 | Temporary installation of DB as directed by Engineer-in-charge.(Refer Sec V Part A, Clause No.18) |
| 99 | Temporary laying of LT cables of following sizes in open air / in Built in trench. (Refer Sec VI (MNC), Clause No.30). |
| 100 | Sizes up to 3.5C X 70 Sq.mm Aluminium conductor (Refer Sec VI (MNC), Clause No.30). |
| 101 | Removal of light fixtures (Refer Sec VI (MNC), Clause No.21). |
| 102 | Removal of light fixtures in labs and low bay areas |
| 103 | Removal of various sizes of surface mounted GI/ PVC Conduit from wall/column/beam and transportation to storage yard (Refer Sec VI (MNC), Clause No.19). |
| 104 | Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28). |
| 105 | Removal of ceiling/Wall mounting/Exhaust fans of following sizes in labs/building/high bay/toilet in IGCAR (Refer Sec VI (MNC), Clause No.19). |
| 106 | Fans Up to 5 Mtrs height |
| 107 | Removal of 1.5 or 2.5 or 4 sq.mm aluminium wire from concealed/ Exposed PVC / ERW / Flo-coated Metal conduits on roof or wall conduits as per the detailed scope of work.(Refer Sec V Part A, Clause No.19) |
| 108 | Removal of the following old fuse DB's / SFU equipement / VTPN DB's already installed / embedded in wall, along with the removal of cable/ wires end terminations , transporting the removed equipment to storage yard as directed by Engineer-in -charge.(Refer Sec V Part A, Clause No.20) |
| 109 | 63A/100A/125A, 500V, TP/TPN/SFU/ Combination SFU or 4/6/8/12 Way SPN or 4/8 WAY TPN DBs |
| 110 | Plain Cement Concrete.(Refer Sec VI, Clause No.26) |
| 111 | 1:2:4 Plain Cement Concrete |
| 112 | Providing and fixing double Tubular scaffolding system using H-Frames / APS system or (cup lock type) on the exterior side upto seven story height made with 40mm dia M.S. tube 1.5m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in-charge. The elevation area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding (Refer Section V, Clause No: 21) |
| 113 | Equipment/cable drums weighing upto 100 kgs for a distance more than 500 mtrs and upto a distance of 5 kms. |
| 114 | Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5) |
| 115 | 3/3.5/4 Core Above 25 & Upto 120 Sqmm |
| 116 | Removal of various sizes of MS box / switch box from the wall / panel (Refer Sec VI (MNC), Clause No.19). Please Enable Macros to View BoQ information |