| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point:- |
| 3 | Medium Point:- |
| 4 | Long Point:- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 X 1.5 sq mm |
| 9 | 2 X 2.5 sq mm |
| 10 | 3 X 1.5 sq mm |
| 11 | 4 X 4 sq mm |
| 12 | 4 X 6 sq mm |
| 13 | 4 X 10 sq mm |
| 14 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 15 | 1 X 1.5 sq mm |
| 16 | 1 X 2.5 sq mm |
| 17 | 1 X 6 sq mm |
| 18 | Supplying and laying of following sizes XLPE insulated PVC sheathed Aluminium conductor Un-armoured cable including necessary connection etc as required. |
| 19 | 3 core 4 Sq mm |
| 20 | 3.5 core 25 Sq mm |
| 21 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 22 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 23 | 100 amps TPN 415 volts front handle cubical main switch (HRC):- |
| 24 | 63 amps TPN 415 volts front handle cubical main switch (HRC):- |
| 25 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 26 | 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 27 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 28 | (2+4) / 6 way SPN MCB DB (single door):- |
| 29 | 4 way horizontal TPN MCB DB (Double door):- |
| 30 | 6 way horizontal TPN MCB DB (Double door):- |
| 31 | 4 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
| 32 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 33 | 6 to 32 amps SP MCB:- |
| 34 | 6 to 32 amps DP MCB:- |
| 35 | 6 to 32 amps TP MCB:- |
| 36 | 40/50/63 amps TP MCB:- |
| 37 | 40/50/63 amps FP MCB:- |
| 38 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 39 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 40 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 41 | Electronic 4 step mini fan regulator |
| 42 | 32 amps DP kit kat switch:- |
| 43 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 44 | 20/25 amps single phase motor starter switch (2M):- |
| 45 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 46 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 47 | 1-2 module plastic switch board:- |
| 48 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 49 | 1-2 module :- |
| 50 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 51 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 52 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 53 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 54 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 55 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 56 | 36 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 57 | 50 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 58 | 6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65):- |
| 59 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 60 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 61 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 62 | 40 mm dia |
| 63 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 64 | 1.5 sqmm - 4 sqmm Cable:- |
| 65 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 66 | 2.5 sq mm |
| 67 | 4 sq mm |
| 68 | 6 sq mm |
| 69 | 10 sq mm |
| 70 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 71 | 4/6 sq mm |
| 72 | 16 sq mm |
| 73 | 25 sq mm |
| 74 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 75 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 76 | Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length (up to 30 cm) etc. as required :- Please Enable Macros to View BoQ information |