| 1 | Supply,laying & testing of Polycab make following size of XLPE insulated,PVC sheathed,round/strip armoured aluminium coductor power cable of 1100 volt grade laid directly underground/Surface with sand cushioning,brick protection clamped on hume pipe/PVC pipe inside masonry cable trench/on the cable trey/through as the case may be including cost of saddles /clamps/cable markers etc but excluding the cost of G.I pipe /hume pipe/PVC pipe compete with making good the damages caused as required and as per direction of Engineer-in-charge. |
| 2 | 3.5C X 95 sqmm Al-Ar cable |
| 3 | 3.5C X 50 sqmm Al-Ar cable |
| 4 | 3.5C X 35 sqmm Al-Ar cable |
| 5 | 4C X 16 sqmm Al-Ar cable |
| 6 | 4C X 50 sqmm Al-Ar cable |
| 7 | 3C X 6 sqmm Cu-Ar cable |
| 8 | 4C X 2.5 sqmm Cu-Ar cable |
| 9 | Supply and laying of 4c X 6 Sqmm Flexible cord wire |
| 10 | Supply of materials and making of end termination of with brass double compression cable glands and bi-metallic crimping type cable lugs for PVC insulated & PVC sheathed aluminium conductor armoured power cable of 1100 volt grade of the following sizes complete as required and as per direction of EIC. |
| 11 | 3.5C X 95 sqmm Al-Ar cable |
| 12 | 3.5C X 50 sqmm Al-Ar cable |
| 13 | 3.5C X 35 sqmm Al-Ar cable |
| 14 | 4C X 16 sqmm Al-Ar cable |
| 15 | 4C X 50 sqmm Al-Ar cable |
| 16 | 3C X 6 sqmm Cu-Ar cable |
| 17 | 4C X 2.5 sqmm Cu-Ar cable |
| 18 | 110mm dia HDPE pipe laying in ground with cutting, jointing including excavation and refilling the trench. |
| 19 | Supply,Installation,Testing and Commissioning of Outdoor /Iindoor floor/wall mounted type Distribution board made out of 2/1.6mm CRCA steel sheet duly painted by epoxy light grey enamel paint having following arrangements. |
| 20 | MAIN LT PANEL(INDOOR FLOOR MOUNTED TYPE) |
| 21 | Incomer-i) 1no 630A 4P ATS with Controller (SOCOMEC/ELMEASURE) |
| 22 | Incomer-ii) 1no 630A 4P MCCB(50kA) with ROM and both side Spreader link(LEGRAND/L&T) |
| 23 | Busbar-4bar Al.bus duly pvc sleeved (size-60X10m) |
| 24 | Outgoing-i) 2nos 250A TP MCCB(25kA) with ROM and both side spreader link followed by 1set ON/OFF indicating lamp and digital MFM with CTs. |
| 25 | ii) 1no 160A TP MCCB(25kA) with ROM and both side spreader link followed by 1set ON/OFF indicating lamp and digital MFM with CTs. |
| 26 | iii) 3nos 125A TP MCCB(25kA) with ROM and both side spreader link followed by 1set ON/OFF indicating lamp and digital MFM with CTs. |
| 27 | iv) 2nos 100A TP MCCB(25kA) with ROM and both side spreader link followed by 1set ON/OFF indicating lamp and digital MFM with CTs. |
| 28 | v) 8nos 63A TP MCCB(25kA) with ROM and both side spreader link followed by 1set ON/OFF indicating lamp and digital MFM with CTs. |
| 29 | Inst-i) 3nos R,Y,B phase indicating lamp with 4A SP MCB. |
| 30 | ii) 1set of Digital MFM with 3nos 600/5A CTs |
| 31 | iii) 1set 50/51(OVER VOLTAGE RELAY) |
| 32 | iv) 1no 50kA 4P (T1+T2)VSD with 4nos 32A SP MCB. |
| 33 | (Duly Factory wired) |
| 34 | MAIN LIGHTING DB |
| 35 | Incomer- 1no 125A 4P MCCB(25kA) with ROM and both side Spreader link(LEGRAND/L&T) |
| 36 | Busbar-4bar Al.bus duly pvc sleeved (size-30X5m) |
| 37 | Outgoing-i) 1nos 100A 4P MCCB(25kA) with ROM and both side spreader link(FOR 60 KVA UPS). |
| 38 | ii) 9nos 63A 2P MCB. |
| 39 | Inst-i) 3nos R,Y,B phase indicating lamp with 4A SP MCB. |
| 40 | ii) 1set of Digital Voltmeter. |
| 41 | (Duly Factory wired) |
| 42 | MAIN PDB |
| 43 | Incomer- 1no 100A TP MCCB(25kA) with ROM and both side Spreader link(LEGRAND/L&T) |
| 44 | Busbar-4bar Al.bus duly pvc sleeved (size-30X5m) |
| 45 | Outgoing-i) 6nos 40A 4P MCB. |
| 46 | ii) 2nos 25A TP MCB. |
| 47 | Inst-i) 3nos R,Y,B phase indicating lamp with 4A SP MCB. |
| 48 | ii) 1set of Digital Voltmeter. |
| 49 | (Duly Factory wired) |
| 50 | HVAC MAIN DB |
| 51 | Incomer- 1no 125A TP MCCB(25kA) with ROM and both side Spreader link(LEGRAND/L&T) |
| 52 | Busbar-4bar Al.bus duly pvc sleeved (size-30X5m) |
| 53 | Outgoing-i) 3nos 63A TP MCB. |
| 54 | ii) 2nos 40A TP MCB. |
| 55 | iii) 3nos 25A TP MCB. |
| 56 | Inst-i) 3nos R,Y,B phase indicating lamp with 4A SP MCB. |
| 57 | ii) 1set of Digital Voltmeter. |
| 58 | (Duly Factory wired) |
| 59 | EXTERNAL LIGHTING |
| 60 | Incomer- 1no 63A 4P MCB with 70A TP power contactor having Time switch. |
| 61 | Busbar-4bar Al.bus duly pvc sleeved (size-25X5m) |
| 62 | Outgoing-i) 4nos 32A 4P MCB. |
| 63 | Inst-i) 3nos R,Y,B phase indicating lamp with 4A SP MCB. |
| 64 | (Duly Factory wired) |
| 65 | PDB-1(PLANETARIUM)(COMPANY MADE) |
| 66 | Company made having 6way 7 segment DB with 63A 4P MCB as Incomer followed by 3nos 40A 2P RCCB(100mA) Each RCCB controlled 6nos 25/32A SP MCB as outgoing. |
| 67 | PDB-2(AUDITORIUM(COMPANY MADE) |
| 68 | Company made having 6way 7 segment DB with 63A 4P MCB as Incomer followed by 3nos 40A 2P RCCB(100mA) Each RCCB controlled 6nos 25/32A SP MCB as outgoing. |
| 69 | LDB-7(PLANETARIUM)(COMPANY MADE) |
| 70 | Company made having 8way 7 segment DB with 63A 4P MCB as Incomer followed by 3nos 40A 2P RCCB(100mA) Each RCCB controlled 8nos 6/10A SP MCB as outgoing. |
| 71 | PDB-3/4/5/6(COMPANY MADE) |
| 72 | Company made having 4way TPN DB with 40A 4P MCB as Incomer and 12nos 32A SP MCB as outgoing. |
| 73 | AC-DB-1&2(COMPANY MADE) |
| 74 | Company made having 6way TPN DB with 63A 4P MCB as Incomer and 18nos 20-32A SP MCB as outgoing. |
| 75 | LDB-1/2/3/4/5/6(COMPANY MADE) |
| 76 | Company made having 12way SPN DB with 63A 2P MCB as Incomer and 10nos 6-20A SP MCB as outgoing. |
| 77 | EMERGENCY LIGHT DB(UPS)-1/2(COMPANY MADE) |
| 78 | Company made having 12way SPN DB with 63A 2P MCB as Incomer and 10nos 6-10A SP MCB as outgoing. |
| 79 | N.B: The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed. Please Enable Macros to View BoQ information |