| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR/MAINTENANCE OF UG CABLES, LT PANELS/BUSBAR CHAMBERS, APFC PANELS, ACBS/MCCBS AND CONNECTED ITEMS AT HOLESWAR UNDER GE(N)TEZPUR Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8277/E8) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified. |
| 3 | Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified and directed. |
| 4 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified and directed. |
| 5 | M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. |
| 6 | M&L laying well burnt old size bricks, sub calss \\"B\\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed. |
| 7 | M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed. |
| 8 | M&L relaying serviceable LT cable of any size retrieved from taking down or up of UG cable from the relevant items complete all as specified and directed by Engr-in-charge.(Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block and pipe shall be measured and paid separately under relevant items). |
| 9 | Materials and labour for earthing complete with MS galvanised steel earth plate electrode 600mm x 600mm x6mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected with 32x6mm galvanised iron or steel earthing lead of 7.5m long to be protected by galvanized iron pipe 40mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanized iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate) 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work, excavation, returned filling and removal of surplus earth upto a distance not exceeding 50 m etc all shown on electrical plate No. 3 of MES schedule Part-I (2009) complete including test point and testing on completion including dismantling of old unserviceable existing earthing complete all as specified and directed. |
| 10 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 2 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 11 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 12 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 35 sqmm 3½ core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 13 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 50 sqmm 3½ core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 14 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 70 sqmm 3½ core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 15 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 95 sqmm 3½ core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 16 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 150 sqmm 3½ core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 17 | M&L for GI pipe 40 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. including taking up old unserviceable existing complete all as specified and directed. |
| 18 | M&L for GI pipe 80 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. including taking up old unserviceable existing complete all as specified and directed. |
| 19 | M&L LT cable jointing kit heat shrinkable type 1100 V (Earthed) with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm complete all as specified and directed. |
| 20 | M&L LT cable jointing kit heat shrinkable type 1100 V (Earthed) with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 sqmm complete all as specified and directed. |
| 21 | M&L LT cable jointing kit heat shrinkable type 1100 V (Earthed) with jointing material and accessories suitable for 2/3.5/4 core XLPE armoured aluminium conductor cable of size upto 35 sqmm complete all as specified and directed. |
| 22 | M&L LT cable jointing kit heat shrinkable type 1100 V (Earthed) with jointing material and accessories suitable for 2/3.5/4 core XLPE armoured aluminium conductor cable of size 150 to 135 sqmm complete all as specified and directed. |
| 23 | S & F in replacement Moulded Case Circuit Breaker (MCCB), 400Amps, breaking capacity 36KA, 4P, 415V, 50 Hz, Adjustable Thermal & magnetic tripping system Conforms to IS13947-2 & IEC-60947-2, Ics=100%, Icu as per IEC 60947-II, Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge. |
| 24 | S & F in replacement Moulded Case Circuit Breaker (MCCB), 250Amps, breaking capacity 36KA, 4P, 415V, 50 Hz, Adjustable Thermal & magnetic tripping system Conforms to IS13947-2 & IEC-60947-2, Ics=100%, Icu as per IEC 60947-II, Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge. |
| 25 | S & F in replacement Moulded Case Circuit Breaker (MCCB), 200Amps, breaking capacity 25KA, 4P, 415V, 50 Hz, Adjustable Thermal & magnetic tripping system Conforms to IS13947-2 & IEC-60947-2, Ics=100%, Icu as per IEC 60947-II, Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge. |
| 26 | S & F in replacement Moulded Case Circuit Breaker (MCCB), 160Amps, breaking capacity 25KA, 4P, 415V, 50 Hz, Adjustable Thermal & magnetic tripping system Conforms to IS13947-2 & IEC-60947-2, Ics=100%, Icu as per IEC 60947-II, Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge. |
| 27 | S & F in replacement Moulded Case Circuit Breaker (MCCB), 63Amps, breaking capacity 16KA, 4P, 415V, 50 Hz, Adjustable Thermal & fixed magnetic tripping system Conforms to IS13947-2 & IEC-60947-2, Ics=100%, Icu as per IEC 60947-II, Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge. |
| 28 | S & F in replacement Moulded Case Circuit Breaker (MCCB), 100Amps, breaking capacity 25KA, 4P, 415V, 50 Hz, Adjustable Thermal & magnetic tripping system Conforms to IS13947-2 & IEC-60947-2, Ics=100%, Icu as per IEC 60947-II, Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge. |
| 29 | S & F in replacement Moulded Case Circuit Breaker (MCCB), 40Amps, breaking capacity 25KA, 4P, 415V, 50 Hz, Adjustable Thermal & magnetic tripping system Conforms to IS13947-2 & IEC-60947-2, Ics=100%, Icu as per IEC 60947-II, Adjustable Overload setting Ir=[0.8 to 1.0] xIn, complete all as specified and directed by Engnr-in-charge. |
| 30 | M & L in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long icluding necessary fixing arrangement using MS clamps,nuts & bolts complete all as specified and directed. |
| 31 | S & F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed |
| 32 | M & L Alluminium strip 25 x 3.15 mm with procelain saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 33 | S & F in repairs Galvanised iron strip 32 x 6mm buried in ground or fixed to Roof, Walls by using appropriate insulating Boxes with screws complete all as specified and directed. |
| 34 | Supply and fixing in repair copper strip 32 x 6 mm fixed in ducts / on wall / in trenches / floors etc for earthing complete fixed to equipment / test point / earth electrode complete all as specified and directed |
| 35 | M&L Paint to existing LT panel board of any type complete with two coat of weather proof synthetic enamel paint after preperation of the surface by scrapping emery paper complete all as directed by Engr-in-Charge. |
| 36 | Supply and fix in replacement of LT cable tray of suitable size not less than 350 X 25 X 2.5mm GI Perforated Tray complete all as specified and directed. |
| 37 | Supply and fix in replacement of LT cable tray of suitable size not less than 300 x 60 x 50 mm PVC Perforated Tray complete all as specified and directed. |
| 38 | Supply and fix in repair cable lugs aluminium any type suitable for cable up to 70 sqmm including necessary crimping with crimping tool complete all as specified and directed . |
| 39 | Supply and fix in repair cable lugs aluminium any type suitable for cable 95 to 120 sqmm including necessary crimping with crimping tool complete all as specified and directed . |
| 40 | Supply and fix in repair cable lugs aluminium any type suitable for cable 150 to 240 sqmm including necessary crimping with crimping tool complete all as specified and directed . |
| 41 | Supply and fix in repair cable lugs aluminium any type suitable for cable 300 to 400 sqmm including necessary crimping with crimping tool complete all as specified and directed. |
| 42 | Supply and fix in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white ,with letters and conventional skull and bone in postal red color and fixed with flat iron clamps, nuts, bolts , and washers of size 200mmx 150 mm for LT Note : (Note:-the printing shall be hand written only stancils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width .) |
| 43 | Material and labour for PCC 1:3:6 type C-2 using 20 mm graded crushed stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified |
| 44 | S&F in repair Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hzsystem of capacity 40 KVAR with incoming MCCBs all complete as specified and directed by Engr-in-Charge. |
| 45 | M&L for repair to LT panel box/body by replacing the damaged/rusted MS sheet of existing gauge fabricated cut to size of original length incl providing hinges and other hard ware item like handless etc. |
| 46 | Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.5x1.0x0.6)m, angle iron of size 50X50X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS:The bus-bars shall be made up of 04 Nos tinned alluminium 500 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INCOMING :MCCB 4 pole, 415 Volts, 400 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS :MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete.MCCB 4 pole, 415 Volts, 250 Amps, 25 kA for out going -01 NosMCCB 4 pole, 415 Volts, 200 Amps, 25 kA for out going -01 Nos MCCB 4 pole, 415 Volts,100 Amps, 16 kA for out going -02 Nos Description of Item No 45 is contd to 46 |
| 47 | INSTRUMENTATION SYSTEM :(a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos.NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 48 | Meterial and labour for making locking provision to the LT panel board of any size/type by providing MS flat iron 25x6 mm up to lengh 15cm duly welded to the both front and back door duly holed for making provision for lock including welding of brocken/unserviceable hinges/mounting arrangements of doors and matching with enamel paint of existing colour on the disturbed surfaces all as specified and directed by Engr-in-Chrage. |
| 49 | Cutting of wall/hard standing for laying of cables and making good the existing surface with using PCC type B1 (1:2:4) using 20mm graded aggregate excavation and earth work complete all as specified and directed |
| 50 | Supply, install, testing & commissioning of LT busbar chamber of size (0.60x0.60x1.0)m CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 50X50X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS:The bus-bars shall be made up of 04 Nos Aluminium 600 A rated not less than 60mmx10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INSTRUMENTATION SYSTEM :(a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b) 3 Ph Digital Voltmeter CI 1.0 - 01 No (c) MCCB 200Amp,4P,25KA -01Nos (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos.NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier.2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 51 | Taking out / removing the defective barrier assembly from the voltage stabilizer by manually / using chain pully block, transporting to workshop, removing the burnt out windings, cleaning and rewinding with super enamelled copper wire of existing size, varnishing, heating and transporting to site for re-fixing the same with additional transformer oil and all small parts which are not included in item no -5 are deemed to be included in item rate for 100 KVA 3 Phase all complete as specified and directed. |
| 52 | Cleaning of internal surfaces of Oil Cooled Voltage Stabilizer to free from dust, sedimentation & rust, removing transformer Oil, filtering and refilling, by additional transformer oil & re-fixing the barrier assembly / transformer, including connecting all electric, electronic & mechanical components, testing and commissioning for 100 KVA 3 Phase all complete as specified and directed. |
| 53 | S&F in repair Push Button Switch complete all as specified and directed by Engineer-in-charge. |
| 54 | S&F in repair Auto manual Switch complete all as specified and directed by Engineer-in-charge. |
| 55 | S&F in repair Potentiometer complete all as specified and directed by Engineer-in-charge. |
| 56 | S&F in repair Voltmeter (Digita) complete all as specified and directed by Engineer-in-charge. |
| 57 | S&F in repair Ampere Meter with C. T. (Digital) complete all as specified and directed by Engineer-in-charge. |
| 58 | S&F in repair Electronic Circuit Card (P C B) complete all as specified and directed by Engineer-in-charge. |
| 59 | S&F in repair Micro Processor Based Control Card for Each Phase complete all as specified and directed by Engineer-in-charge. |
| 60 | S&F in repair Trigger Transformer complete all as specified and directed by Engineer-in-charge. |
| 61 | S&F in repair Rotary Switch 5 amps for R Y B Phases complete all as specified and directed by Engineer-in-charge. |
| 62 | S&F in repair Servo Motor 20 Kg Torque complete all as specified and directed by Engineer-in-charge. |
| 63 | S&F in repair Carbon Brush (20amps to 200 amps) complete all as specified and directed by Engineer-in-charge. |
| 64 | S&F in repair Carbon Holder & Spring complete all as specified and directed by Engineer-in-charge. |
| 65 | S&F in repair Servo motor gear pinion complete all as specified and directed by Engineer-in-charge. |
| 66 | S&F in repair R C Net work for 20 Kg Motor complete all as specified and directed by Engineer-in-charge. |
| 67 | S&F in repair Drive assembly 100 KVA per phase complete all as specified and directed by Engineer-in-charge. |
| 68 | M&L for Dehydration of Transformer oil with high viscosity, high resistance to oxidation & thermal stability mainting BDV Value of 55-60 KV in 2.5mm rod gap complete all as specified and directed by Engineer-in-charge. |
| 69 | M&L for Top up new Transformer oil with high viscosity , high resistance to oxidation & thermal stability mainting BDV Value of 55-60 KV in 2.5mm rod gap complete all as specified and directed by Engineer-in-charge. |
| 70 | Rewinding of Dimmer Starter (Barrier) for 100 KVA Single / 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge complete all as specified and directed by Engineer-in-charge. . |
| 71 | Rewinding of Transformer assembly for 100 KVA Single / 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge complete all as specified and directed by Engineer-in-charge. . Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |